DRAGONPUCK/OS/DP3/W2-847 OSRAM SYLVANIA, DRAGONPUCK/OS/DP3/W2-847 Datasheet - Page 3

LED LIGHT MODULE, 3 LED, WHITE

DRAGONPUCK/OS/DP3/W2-847

Manufacturer Part Number
DRAGONPUCK/OS/DP3/W2-847
Description
LED LIGHT MODULE, 3 LED, WHITE
Manufacturer
OSRAM SYLVANIA
Series
DRAGONpuckr

Specifications of DRAGONPUCK/OS/DP3/W2-847

Led Module Type
Board + LED
Led Color
White
Cct
4700K
Power Module Configuration
Circular
Forward Current @ Test
350mA
Power Rating
3.6W
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
10. Modules may be hot to touch. Use appropriate caution.
Assembly Information
Application Notes
Ordering and Specification Information
Item
Number
70108
70107
70120
70121
70124
70123
70122
*All data are related to the entire module.
Due to the special conditions of the manufacturing processes of LED, the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond
to the actual parameters of each single product which could differ from the typical data.
6. Please ensure that the power supply is of adequate power to operate the total load. For the OT 09/100-120/350E and
7. Pay attention to standard ESD precautions when installing the module.
8. Dimming of the DRAGONpuck is possible using the Pulse Width Modulation (PWM) functionality of the OPTOTRONIC OT 09/10-24/350 DIM/E.
9. Damage by corrosion will not be honored as a materials defect claim. It is the user’s responsibility to provide suitable protection against
1. The mounting of the module is facilitated by means of a M3x8 (8mm) screw which fits to a threaded hole in the rear of the DRAGONpuck housing.
2. The module should be in good thermal contact with the designed metallic mounting surface. Use of an appropriate heat sink compound is
3. To obtain maximum LED-lifetime please read carefully the recommended procedures concerning thermal management in our application
1. Module is intended for use with 350 mA constant current drive condition as is provided by the OT9/100-120/350 and OT9/10-24/350 DIM E (see
2. Installation of the DRAGONpuck must include provision for thermal management to avoid premature failure of the product and to obtain expected
4. Concerning fixture design, it is important to understand that once heat is transferred to a “heat sink”, that heat must still be allowed to escape
5. The fixture makers’ strategy should be to design a prototype fixture and test that fixture in an appropriate ambient environment while monitoring
3. There is no exact installation prescription to obtaining an appropriate Tc-Point temperature because every fixture design is different. In general,
OT09/10-24/350DIM/E power supplies, the maximum number of DRAGONpuck modules per power supply is 2 modules
for the colors white, green and blue and 3 modules for yellow and red.
Dimming through the regulation of current amplitude will result in a spectral color shift.
corrosive agents such as moisture and condensation and other harmful elements.
The length of the screw depends on the thickness of the heat sink used.
recommended to eliminate air gaps.
note “Lifetime of LED-modules” before beginning construction of luminaries. This application note is available from your OSRAM SYLVANIA
representative.
PIB ECS052 for details). The module is not intended for use with constant voltage power supplies, including other OSRAM LED power supplies.
service life. Service life (i.e. lumen depreciation) is primarily a function of LED temperature which is to be monitored on the circuit board at the
designated “Tc-Point”.
the “system”. A heat sink transferring the thermal energy to the inside of an enclosed cavity may ultimately be of little use.
the temperature at the Tc-Point which should be allowed enough time to reach thermal equilibrium. In the end, the heat sink areas from the chart
below only represent a starting point for initial design work while the Tc-Point temperature serves as the emperical test of proper thermal manage-
ment. Tc-Point temperature can be measured with a standard thermocouple in direct contact with the circuit board at the Tc-Point or by use of
ML4C Series non-reversible OMEGALABELS (www.omega.com) or equivalent.
the DRAGONpuck module should be mounted to a clean, flat metal surface which has enough surface area to transfer the heat from the module
to the surrounding air. The metal surface can be part of a conventional finned heat sink or can be part of the mass of the fixture itself.
Ordering
Abbreviation
DRAGONpuck/OS/DP3/W2-865
DRAGONpuck/OS/DP3/W2-854
DRAGONpuck/OS/DP3/W2-847
DRAGONpuck/OS/DP3/A1
DRAGONpuck/OS/DP3/Y1
DRAGONpuck/OS/DP3/V1
DRAGONpuck/OS/DP3/B1
Yellow
Color
White
White
White
Verde
Blue
Red
Number of
LEDs
3
3
3
3
3
3
3
Current
(mA)*
350
350
350
350
350
350
350
Power
(W)*
3.6
3.6
3.6
2.4
2.4
3.6
3.6
Angle (°)*
Radiance
20
20
20
16
16
16
16
Wavelength(nm)
Color Temp (K)*
617 nm
587 nm
505 nm
470 nm
6500K
5400K
4700K
Lum. Intensity
(cd)*
285
285
285
215
215
285
100

Related parts for DRAGONPUCK/OS/DP3/W2-847