HLMP-K401 Avago Technologies US Inc., HLMP-K401 Datasheet - Page 4

LED, 3MM, ORANGE, 2.1MCD, 602NM

HLMP-K401

Manufacturer Part Number
HLMP-K401
Description
LED, 3MM, ORANGE, 2.1MCD, 602NM
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HLMP-K401

Bulb Size
3mm
Led Color
Orange
Luminous Intensity
2.1mcd
Viewing Angle
60°
Forward Current If
10mA
Forward Voltage
1.9V
Led Mounting
Through Hole
Lens Shape
Round
Wavelength Typ
602nm
Color
Orange
Millicandela Rating
2.1mcd
Current - Test
10mA
Wavelength - Dominant
602nm
Wavelength - Peak
600nm
Voltage - Forward (vf) Typ
1.9V
Lens Type
Diffused, Orange Tinted
Lens Style/size
Round, 3mm, T-1
Package / Case
Radial - 2 Lead
Height
4.70mm
Mounting Type
Through Hole
Resistance Tolerance
602nm
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Luminous Flux @ Current - Test
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
ATIHLMP-K401

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HLMP-K401
Manufacturer:
AVAGO
Quantity:
40 000
Part Number:
HLMP-K401
Manufacturer:
AVAGO
Quantity:
50 000
Part Number:
HLMP-K401-E0002
Manufacturer:
AVAGO
Quantity:
40 000
Part Number:
HLMP-K401-E0002
Manufacturer:
AVAGO
Quantity:
50 000
Part Number:
HLMP-K401-EF000
Manufacturer:
AVAGO
Quantity:
40 000
Absolute Maximum Ratings at T
Notes:
1. See Figure 5 (HER/Orange), 10 (Yellow), or 15 (Green/Emerald Green) to establish pulsed operating conditions.
. For Red, Orange, and Green series derate linearly from 50°C at 0.5 mA/°C. For Yellow series derate linearly from 50°C at 0. mA/°C.
3. For Red, Orange, and Green series derate power linearly from 5°C at 1.8 mW/°C. For Yellow series derate power linearly from 50°C at 1.6 mW/°C.
4. The transient peak current is the maximum non-recurring peak current that can be applied to the device without damaging the LED die and
4
Parameter
Peak Forward Current
DC Current
everse Voltage (IR = 100 μA)
Transient Forward Current
LED Junction Temperature
Operating Temperature Range
Storage Temperature Range
Average Forward Current
wirebond. It is not recommended that the device be operated at peak currents beyond the peak forward current listed in the Absolute Maximum
Ratings.
[]
[1]
[4]
(10 μsec Pulse)
A
= 25°C
HER/Orange
90
5
30
5
500
110
-40 to +100
-40 to +100
60
0
0
5
500
110
-40 to +100
-40 to +100
Yellow
Green
90
5
30
5
500
110
-0 to +100
-40 to +100
Units
mA
mA
A R
V
mA
°C
°C
°C