HCPL-250L-320E Avago Technologies US Inc., HCPL-250L-320E Datasheet - Page 6

no-image

HCPL-250L-320E

Manufacturer Part Number
HCPL-250L-320E
Description
Optocoupler(1MBd,3.3V),SMD+UL+LF
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-250L-320E

Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
8mA
Data Rate
1Mbps
Propagation Delay High - Low @ If
350ns @ 16mA
Current - Dc Forward (if)
25mA
Input Type
DC
Output Type
Open Collector
Mounting Type
Surface Mount, Gull Wing
Package / Case
8-SMD Gull Wing
Output Device
Transistor With Base
Number Of Elements
1
Reverse Breakdown Voltage
5V
Forward Voltage
1.7V
Forward Current
50mA
Package Type
PDIP SMD
Collector Current (dc) (max)
8mA
Isolation Voltage
3750Vrms
Power Dissipation
100mW
Current Transfer Ratio
50%
Pin Count
8
Mounting
Surface Mount
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Insulation and Safety Related Specifications
Parameter
Minimum External Air
Gap (External Clearance)
Minimum External Tracking
(External Creepage)
Minimum Internal Plastic
Gap (Internal Clearance)
Tracking Resistance
(Comparative Tracking
Index)
Isolation Group
IEC/EN/DIN EN 60747-5-2Insulation Related Characteristics
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Figure 16, Thermal Derating curve.)
Insulation Resistance at T
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in applica-
tion.
6
for rated mains voltage ≤ 150 V rms
for rated mains voltage ≤ 300 V rms
for rated mains voltage ≤ 600 V rms
V
with t
V
t
Case Temperature
Input Current
Output Power
m
IORM
IORM
= 60 sec, Partial Discharge < 5 pC
m
x 1.875 = V
x 1.5 = V
= 1 sec, Partial Discharge < 5 pC
PR
, Type and Sample Test,
PR
, 100% Production Test
ini
S
, V
= 10 sec)
IO
= 500 V
Symbol
L (101)
L (102)
CTI
8-Pin DIP
(300 Mil)
Value
7.1
7.4
0.08
200
IIIa
SO-8
Value
4.9
4.8
0.08
200
IIIa
Symbol
V
V
V
V
T
I
P
R
S,INPUT
S
IORM
PR
PR
IOTM
S,OUTPUT
S
Units
mm
mm
mm
Volts
PDIP Option 060
I-IV
I-III
55/85/21
2
630
1181
945
6000
175
230
600
≥ 10
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance, conductor to
conductor, usually the direct distance
between the photoemitter and photodetector
inside the optocoupler cavity.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
9
SO-8 Option 60
I-IV
I-III
I-II
55/85/21
2
566
1063
849
4000
150
150
600
≥ 10
9
Units
V
˚C
mA
V
V
V
mW
peak
peak
peak
peak

Related parts for HCPL-250L-320E