9G1212G1021 SANYO DENKI - SANACE FANS, 9G1212G1021 Datasheet

AXIAL FAN, 120MM, 12VDC, 980mA

9G1212G1021

Manufacturer Part Number
9G1212G1021
Description
AXIAL FAN, 120MM, 12VDC, 980mA
Manufacturer
SANYO DENKI - SANACE FANS
Datasheet

Specifications of 9G1212G1021

External Height
120mm
External Width
120mm
External Depth
38mm
Current Type
DC
Supply Voltage
12VDC
Flow Rate
137CFM
Noise Rating
49dBA
Power Connection Type
Lead Wires
Bearing Type
Ball
Flow Rate - Imperial
137CFM
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
COOLING SYSTEM
San Ace
Products Information

Related parts for 9G1212G1021

9G1212G1021 Summary of contents

Page 1

COOLING SYSTEM San Ace Products Information ...

Page 2

...

Page 3

Technical Material ・・・・・・・・・・・・・・・・・・・・・ Product Guide Instruction Manual for Fan ‥‥‥‥‥ Part Numbering System ‥‥‥‥‥‥ DC Fans ‥‥‥‥‥‥‥‥‥‥‥‥‥‥ Thermal Speed Controlled Fans ‥‥‥‥‥ Splash Proof Fans ‥‥‥‥‥‥‥‥‥‥ Oil Proof Fans‥‥‥‥‥‥‥‥‥‥‥‥ Long Life Fans ...

Page 4

2 ...

Page 5

TECHNICAL MATERIAL 3 ...

Page 6

TECHNICAL MATERIAL Overview and characteristics of fan Overview Fan motor is widely used to extend life of your system by cooling off heat of the system that many electrical components are mount very high density and dissipating ...

Page 7

Guideline in selecting a fan How to select an appropriate fan The following example is a guideline regarding how to select an appropriate fan for cooling your system 1. Determining of your system specifications and conditions Determine the temperature rise ...

Page 8

TECHNICAL MATERIAL Characteristics calculation method and description Reliability and life A fan motor generally cools itself as well. The temperature rise of the motor is relatively low and the temperature rise of the grease in the bearings is also low, ...

Page 9

Noise characteristics Noise is average value that measured at l meter away from air intake side of fan that is suspended on special frame in anechoic chamber (as per JIS B 8330). Fan AIR FLOW 1m General specifications Insulation resistance ...

Page 10

TECHNICAL MATERIAL Characteristics calculation procedure and description Measuring air flow and static pressure It is very difficult to measure air flow and static pressure. In fact, the performance curve may vary greatly according to the type of measuring equiment. The ...

Page 11

Operating precautions Operating precautions Storage temperature There is no performance problem when the system is used at between -30℃ and +70℃. There is a possibility that same problem of lubri- cant and insulation inside motor might occur by condensing due ...

Page 12

TECHNICAL MATERIAL Specifications for DC fan sensors Pulse sensor (Tach output type) Pulse sensor outputs two pulse waves per revolution of fan, and it is good to detect fan speed. Pulse sensors can be incorporated in all kinds of BLDC ...

Page 13

Locked rotor sensor (rotation/lock detection type) Locked rotor sensor outputs fan status signals good to check whether the fan is running or locked * Noise from inside the fan or from external devices may effect sensor output, please ...

Page 14

TECHNICAL MATERIAL Specifications for DC fan sensors Low-speed sensor (rotating speed detection type) Low-speed sensor outputs a signal when fan speed goes down to trip point or less good to detect cooling degradation of fan. *Noise from inside ...

Page 15

Specifications for AC fan sensor Specifications of sensor circuit System Speed detection, auto-restart. Power supply VDC ( Sensor circuit I=100mAmax Output performance Vc=27.6Vmax Trip point Response speed Startup delay Detection delay Insulation resistance 10 MΩ or more ...

Page 16

TECHNICAL MATERIAL Common Specifications Overheating protection function Protection Functions: If the fan blades are restricted, an overcurrent occurs and leads to a rise in the fan coil temperature. This can result in reduced performance, damage fire. To prevent ...

Page 17

Safety standards ■ Description of safety standards 1. UL ratings (USA) 2. CSA standards (Canada standards (EU members) Underwriters Laboratories Inc. was established by the American Union of Fire Insurance Underwriters. The purpose ensure ...

Page 18

TECHNICAL MATERIAL 4. Electrical Appliance and Material Safety Law ■ CE marking To distribute their equipment in the EU territory, manufacturers are obligated to give a CE marking as proof that the equipment conforms to related EU directives. Manufacturers use ...

Page 19

Safety standard list AC Fan ■ ✓… UL・CSA・and TÜV acquired Flame size Thickness Model.No Rated voltage UL CSA TÜV CE 109-180 100 28mm 109-183 115 60 60mm × 109-130 100 38mm 109-133 115 109-210 100 20mm 109-213 115 109S050 100 ...

Page 20

TECHNICAL MATERIAL Safety standard list DC Fan ■ * … UL・CSA・and TÜV Pending Flame size Thickness Model.No 9L0412J302 40×40mm 28mm 9L0412H302 9L0412M302 40×40mm 20mm 9WF0424H602 60×60mm 25mm 9WF0624H402 120×120mm 38mm 9WF1224H102 9WP0612H402 9WP0612H4021 60×60mm 25mm 9WP0624H402 9WP0624H4021 9WP1212H102 9WP1212H1021 9WP1224H102 ...

Page 21

COOLING SYSTEMS San Ace DC Fans Long life, low noise axial cooling fans optimized for mostly server or communication devices. Thermal Speed Controlled Fans Two types: external and internal thermistor. Splash Proof Fans Axial cooling fans optimized for outdoor devices ...

Page 22

Product Guide Safety Precautions ・In order to ensure that this product is used safely, be sure that you read and understand the following precautions fully and use the product only as directed. ・Be sure to read these Safety Precautions carefully ...

Page 23

Warning If the fan stops during operation, give proper consideration to the device for its protection. ・ ・ Installation, placement, connections, wiring, or relocation of the product should be performed by knowledgeable or correctly licensed personnel. Never perform such work ...

Page 24

Product Guide Part Numbering System DC Fans Series name / Frame dimensions Voltage frame material 04 40 40mm 05 : × 109P / Plastics 05 52 52mm 12 : × 109R / Plastics 06 60 60mm 24 ...

Page 25

Thermally Speed Controlled Fans 109R 12 12 Series name / Frame dimensions Voltage frame material 05 52 52mm 12 12V : × : 109P Plastics / 60mm etc : × 109R / Plastics 08 80 80mm : × ...

Page 26

Product Guide Cooling Fan Units Example of application Cooling Fan Unit for 1U Server ●We build cooling systems that are most suitable for the client's application. The unit includes a range of cooling fans that are optimally adjusted according to ...

Page 27

Lineup Our rich lineup of cooling fans includes tray that are designed for telecommunication equipment, such as servers, routers and storage devices, as well as some other equipments. DC Cooling Fan DC San Ace 40mm∼200mm square. 10mm∼70mm thickness. Blower San ...

Page 28

Product Guide Electrolytic Corrosion Proof Fans ●This cooling fan prevents electrolytic corrosion of bearings even under conditions where electromagnetic noise is generated. ●Electrolytic corrosion of ball bearings is prevented by using ceramic balls in ball bearings. The ceramic material is ...

Page 29

Lineup ●Electrolytic corrosion proof specification can be applied to our entire San Ace. DC Cooling Fan 40mm to 140mm sq. / 172mm to φ 10mm to 70mm thickness. Long Life Fan 40mm to 140mm sq. / 172mm φ 25mm to ...

Page 30

Product Guide Fans with the PWM control function This picture shows 120×120×38mm fan. ■ PWM Speed Control Scheme Duty cycle=100 Duty cycle=50 Duty cycle=20 Pulse Width Modulation Speed Control Features PWM speed control ...

Page 31

Lineup Fans with the PWM control function ■ Available size and example of characteristics Size Voltage Rated Speed Frequency Model No. (mm) (V) 9GV0412P3J** 40×40×28 12 0∼4,410 9G0612P1G** 60×60×38 12 0∼3,540 9G0812P1G** 80×80×38 12 0∼1,890 9G0912P2G** 92×92×32 12 0∼1,500 9SG1212P1G** ...

Page 32

Product Guide Endurance Fan Series SANYO DENKI's Cooling Fans enjoy wide acceptance by many customers thanks to their high performance and reliability, proven over many years. Within the company's line of Cooling Fan products, the " Endurance Fan Series " ...

Page 33

Lineup Oil resistant materials protect coils and electronic parts. Therefore, even in a severe environment with oil mist, the product maintains stable operation. Life expectancy : 40,000 hours. Applications : All kinds of industrial machines Usage of this product requires ...

Page 34

Product Guide Lineup of Endurance Fan Series For IP55* This cooling fan operates with dependability even in the most severe environments, and is capable of resisting direct jets of water from multiple directions. Life expectancy : 40,000 to 100,000 hours. ...

Page 35

Lineup The Long-Life Fan Series for cooling equipment that must be in operation and maintence-free for long periods of time. Life expectancy:60,000∼200,000 hours Applications:Communications equipment etc Long Life Fan DC Fan San Ace L Series 40mm sq.×28mm thickness 60mm sq.×25mm ...

Page 36

34 ...

Page 37

COOLING SYSTEMS DC FAN Domain diagram Air flow (m 3 /min) Frame dimensions 0.1 0.2 0.3 0 □ □ □ □ mm □ ...

Page 38

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) Dielectric ...

Page 39

Dimensions (unit : mm) +1 4−φ3.5±0.3 40 0 (3) 32±0.3 Mounting hole +30 320 0 (10) Lead Wire AWG26 UL1007 10mm thick Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 39 32±0.3 4-φ3.7 (15) ...

Page 40

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) Dielectric ...

Page 41

Dimensions (unit : mm 4-φ3.5±0.3 (4) 32±0.3 Mounting hole +30 320 0 (10) Lead Wire AWG24 UL1007 20mm thick Reference dimension of mounting holes and vent opening (unit : mm) Air inlet side・Air outlet side 39 32±0.3 ...

Page 42

DC Fans DC Fan "San Ace 40" GV type General specifications Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current ...

Page 43

Dimensions (unit : mm) 4−φ3.5±0.3 Lead Wire Mounting hole AWG26 UL1007 +30 320 0 (10) Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 39 32±0.3 4-φ3.7 (18) 28±0.5 (4) (4) (unit : mm) 40±0.3 32±0.3 ...

Page 44

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) Dielectric ...

Page 45

Air Flow and Static Pressure Characteristics K speed J speed 400 250 250 350 13.2 V 13.2 V 200 200 300 250 150 150 200 100 100 150 100 ...

Page 46

DC Fans DC Fan "San Ace 40" CRA type, Counter Rotating Fan General Specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ...

Page 47

Dimensions (unit : mm) +30 320 0 4−φ3.5±0.3 (10) Mounting Hole (10) +30 320 0 Lead Wire AWG28 UL1007 Inlet Reference Dimension of Mounting Holes and Vent Opening Air Inlet Side・Air Outlet Side 39 32±0.3 4-φ3.7 (18) 56±0.5 (5) (5) ...

Page 48

DC Fans DC Fan Counter Rotating Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse ...

Page 49

Dimensions (unit : mm) +30 320 0 4−φ3.5±0.3 (10) Mounting hole (10) +30 320 0 Lead Wire AWG28 UL1007 Inlet Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 39 32±0.3 4-φ3.7 (15) + ...

Page 50

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) Dielectric ...

Page 51

Dimensions (unit : mm) 52±0.5 42±0.3 Lead Wire AWG24 UL1007 (10) +50 300 0 4-φ3.7±0.3 Mounting hole Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 51 42±0.3 4-φ3.7 (24) (3) (3) (unit ...

Page 52

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) Dielectric ...

Page 53

Specifications Rated Voltage Operating Voltage Range Rated Current Model No. (V) (V) 109R0605H402(4021) 109R0605F402(4021) 5 4.5∼ 5.5 109R0605M402(4021) 109R0612J402(4021) 10.8∼13.2 109R0612G402(4021) 109R0612D402(4021) 10.2∼13.8 109R0612S402(4021) 12 109R0612H402(4021) 6 ∼13.8 109R0612F402(4021) 109R0612M402(4021) 7 ∼13.8 109R0624J402(4021) 21.6∼26.4 109R0624G402(4021) 20.4∼27.6 109R0624D402(4021) ...

Page 54

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity ...

Page 55

Dimensions (unit : mm) +1 60 0 50±0.3 +50 300 0 (10) Lead Wire AWG24 4−φ4.3±0.3 UL1007 Mounting hole Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 59 50±0.3 29.7 4-φ4.5 38±0.5 (3) (3) (unit : mm) ...

Page 56

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) Dielectric ...

Page 57

Specifications Rated Voltage Operating Voltage Range Rated Current Rated Input Model No. (V) (V) 6 ∼13.2 109P0812A202 ( 2021) 12 109P0812H202 ( 2021) 10.2∼13.8 109P0812M202 ( 2021) 12 ∼26.4 109P0824A202 ( 2021) 24 109P0824H202 ( 2021) 20.4∼27.6 ...

Page 58

DC Fans DC Fan "San Ace 80" G Type General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function ...

Page 59

Dimensions (unit : mm) 4-φ4.3±0.3 Mounting hole Lead Wire AWG24 UL1007 +30 300 0 (10) 71.5±0.3 (4) 80±0.5 Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 4-φ4.5 71.5±0.3 78.5 (4) 38±0.5 (unit : mm) 80 ...

Page 60

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥PTC protection system (25mm thick) Current cut system ...

Page 61

Specifications Rated Voltage Operating Voltage Range Rated Current Rated Input Rated Speed Model No. (V) (V) 9G0912A202(2021) 9G0912S202(2021) 12 10.2∼13.8 9G0912H202(2021) 9G0912M202(2021) 9G0924A202(2021) 9G0924S202(2021) 24 20.4∼27.6 9G0924H202(2021) 9G0924M202(2021) 9G0948A202(2021) 9G0948S202(2021) 48 40.8∼55.2 9G0948H202(2021) 9G0948M202(2021) The numbers in ...

Page 62

DC Fans DC Fan "San Ace 92" G Type General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function ...

Page 63

Dimensions (unit : mm) 4−φ4.3±0.3 Mounting hole + 30 300 0 (10) Lead Wire AWG24 UL1007 (4) 82.5±0.3 92±0.5 Reference dimension of mounting holes and vent opening Air outlet side Air inlet side 82.5±0.3 82.5±0.3 4-φ4.5 90.5 (4) 38±0.5 (unit : ...

Page 64

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) Dielectric ...

Page 65

Air Flow and Static Pressure Characteristics H M speed speed 13.8V/27.6V 13.8V/27. 12V/24V 12V/24V 6V/12V 6V/12V ...

Page 66

DC Fans DC Fan "San Ace 120" G type General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function ...

Page 67

Air Flow and Static Pressure Characteristics G speed E speed 140 120 13.8V/27.6V/55.2V 13.8V/27.6V/55.2V 120 100 12V/24V/48V 12V/24V/48V 100 10.2V/20.4V/40.8V 80 10.2V/20.4V/40. → ...

Page 68

DC Fans DC Fan "San Ace 120" G type General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function ...

Page 69

Air Flow and Static Pressure Characteristics G speed E speed 180 140 160 120 13.8V/27.6V/55.2V 13.8V/27.6V/55.2V 140 12V/24V/48V 12V/24V/48V 100 120 10.2V/20.4V/40.8V 10.2V/20.4V/40.8V 80 100 ...

Page 70

DC Fans DC Fan "San Ace 120" SG type General specifications Material ‥‥‥‥‥‥‥‥‥Frame : Aluminum, Impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection ...

Page 71

Dimensions (unit : mm) 8-φ4.3±0.3 +30 300 0 (10) Lead Wire 6.5±0.3 AWG24 104.8±0.3 UL1007 120±0.8 or AWG22 UL1430 Reference dimension of mounting holes and vent opening Air outlet side Air inlet side 4-φ4.5 104.8±0.3 104.8±0.3 118 6.5±0.3 (3.5) (3.5) 38±0.5 ...

Page 72

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) Dielectric ...

Page 73

Dimensions (unit : mm) 4−φ4.3±0.3 Mounting hole (10) +30 300 0 Lead Wire AWG24 UL1007 (6) 113.3±0.3 127±0.8 Reference dimension of mounting holes and vent opening Air outlet side Air inlet side 4-φ4.3 113.3±0.3 123 (6) 38±0.5 (unit : mm) ...

Page 74

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Aluminum, impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 75

Dimensions (unit : mm) 127±0.8 113.3±0.3 (10) +30 300 0 Lead Wire AWG24 UL1007 8−ø4.3±0.3 Mounting hole Reference dimension of mounting holes and vent opening Air outlet side 4-φ4.3 113.3±0.3 123 38±0.5 6±0.3 6±0.3 (unit : mm) Air inlet side ...

Page 76

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) Dielectric ...

Page 77

Dimensions (unit : mm) 4−φ4.3±0.3 Mounting hole (10) +30 300 0 Lead Wire AWG24 UL1007 (5) 124.5±0.5 140±0.8 Reference dimension of mounting holes and vent opening Air outlet side Air inlet side 4-φ4.5 124.5±0.3 138 38±0.5 (5) (unit : mm) ...

Page 78

DC Fans DC Fan "San Ace 150" GV Type General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function ...

Page 79

Dimensions (unit : mm) 4-φ4.5±0.3 (10) +30 300 0 Lead Wire AWG22 UL1430 135±0.5 150±0.8 Reference dimension of mounting holes and vent opening Air outlet side Air inlet side 4-φ4.5 135±0.3 148±0.5 6.5±0.3 6.5±0.3 50±0.5 (unit : mm) 4-φ4.5 135±0.3 ...

Page 80

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) Dielectric ...

Page 81

Dimensions (unit : mm) 8−φ4.5±0.4 Mounting hole +50 300 0 (10) Lead Wire AWG24 UL1007 7.5±0.4 147±0.8 Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 147 4-φ4.5 7.5±0.4 25.4±0.5 (unit : mm) 172 mm 79 ...

Page 82

DC Fans DC Fan "San Ace 172" GV type General specifications Material ‥‥‥‥‥‥‥‥‥Frame : Aluminum , Impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor ...

Page 83

Dimensions (unit : mm) Lead Wire AWG22 UL1430 7.5±0.4 150±0.8 Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 9.5 4-φ4.5 147 8-φ4.5±0.3 7.5±0.4 51±0.8 (unit : mm) 172 mm 81 ...

Page 84

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) Dielectric ...

Page 85

Dimensions (unit : mm) 4-φ4.5±0.3 Mounting hole 150±0.8 (10) +30 300 0 Lead AWG24 UL1007 Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 148 2-φ4.5 9.5 51±0.8 7.5±0.4 7.5±0.4 (unit : mm) 172 mm 83 ...

Page 86

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) Dielectric ...

Page 87

Dimensions (unit : mm) ROTATION 8-φ4.5±0.3 Lead Wire AWG24 UL1007 or AWG22 UL1430 7.5±0.4 162±0.5 Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 162±0.3 4-φ4.5 9.5 7.5±0.4 51±0.8 (unit : mm) 172 mm 85 ...

Page 88

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) Dielectric ...

Page 89

Dimensions (unit : mm) 8−φ4.5 Mounting hole (10) Lead Wire AWG22 UL1007 7.5±0.4 188.4±0.3 Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 188.4 4-φ4.5 Signal connection type VS + VC Brushless DC fan Control IC=2mA max ...

Page 90

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) Dielectric ...

Page 91

Dimensions (unit : mm) ROTATION Lead Wire AWG22 UL1007 SANYO DENKI 12±0.4 188.4±0.3 208±0.5 220±1 Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 208 188.4 8−φ4.3±0.15 For flat head screw 8−φ4.5±0.3 For round head screw ...

Page 92

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) Dielectric ...

Page 93

Dimensions (unit : mm) 4ーφ4.3±0.3 Mounting hole +50 300 00 (10) Lead Wire AWG24 (3) UL1007 50±0 Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 59 4-φ4.5 50±0.3 29.7 (3) 25±0.5 (unit ...

Page 94

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) Dielectric ...

Page 95

Dimensions (unit : mm) 4ーφ4.3±0.3 Mounting hole +50 300 00 (10) Lead Wire AWG24 (4) UL1007 71.5±0.3 25±0.5 80±0.5 Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 4-φ4.5 71.5±0.3 78.5 (4) (unit : mm ...

Page 96

DC Fans DC Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) Dielectric ...

Page 97

Dimensions (unit : mm) 4ーφ4.3±0.3 Mounting hole +50 300 0 (10) Lead Wire AWG24 (4) UL1007 82.5±0.3 25±0.5 92±0.5 Reference dimension of mounting holes and vent opening Air outlet side 90.5 4-φ4.5 82.5±0.3 (4) (unit : mm) Air inlet side ...

Page 98

96 ...

Page 99

COOLING SYSTEMS DC FAN Domain diagram Air flow (m 3 /min) Frame dimensions 0.1 0.2 0.3 0.4 52 □ □ □ mm □ 120 □ mm Thermal Speed Controlled Fans ...

Page 100

DC Fans Thermal speed controlled fans with an external or built-in thermistor External thermistor type 1. Overview For thermal speed controlled fans with an external thermistor, just connect a specified thermistor (or a specified thermistor and a resistor) between the ...

Page 101

At an ambient temperature of 30 ℃ and an equipment load of 100%, the temperature of the cooling fin was 48 temperature of the thermistor placed on the cooling fin was 45 decided to add a 1.5 K Ω ...

Page 102

DC Fans Thermal Speed Controlled Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity ...

Page 103

Specifications Rated Voltage Operating Voltage Range Rated Current Rated Input Rated Speed Model No. (V) (V) 109P0512T7H122 12 10.2∼13.8 Notes:The top row gives characteristics shown when the thermistor temperature is 35℃, while the ...

Page 104

DC Fans Thermal Speed Controlled Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity ...

Page 105

Specifications Rated Voltage Operating Voltage Range Rated Current Rated Input Rated Speed Model No. (V) (V) 109P0612T7H122 12 10.2∼13.8 Note 1: The top row gives characteristics shown when the emperature is 40℃, while ...

Page 106

DC Fans Thermal Speed Controlled Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity ...

Page 107

Specifications Rated Voltage Operating Voltage Range Rated Current Rated Input Rated Speed Model No. (V) (V) 109P0812T6H122 12 10.2∼13.8 Note 1: The top row gives characteristics shown when the emperature is 40℃, while ...

Page 108

DC Fans Thermal Speed Controlled Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity ...

Page 109

Specifications Rated Voltage Operating Voltage Range Rated Current Rated Input Rated Speed Model No. (V) (V) 109P0912T4H122(123) 12 10.2∼13.8 The numbers in( )represent ribless models. Note 1: The top row gives characteristics shown ...

Page 110

DC Fans Thermal Speed Controlled Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity ...

Page 111

Specifications Rated Voltage Operating Voltage Range Rated Current Rated Input Rated Speed Model No. (V) (V) 109P1212T4H122(123) 12 10.2∼13.8 The numbers in( )represent ribless models. Note 1: The top row gives characteristics shown ...

Page 112

110 ...

Page 113

COOLING SYSTEMS DC FAN Domain diagram Air flow (m 3 /min) Frame dimensions 0.1 0.2 0.3 0.4 60 □ mm □ □ mm □ 120 mm 140 □ mm Splash Proof Fans 0.5 0.6 0.7 0.8 0.9 ...

Page 114

DC Fans "IP XX" Protection Grade ■ IP code is laid down in "Degrees of protection provided by enclosures (IP Code) " on JIS C 0920 and IEC 60529. ■IP code is defined as "A coding system to indicate the ...

Page 115

113 ...

Page 116

DC Fans Splash Proof Fan “San Ace 60W” WP type General specifications IP55 (Dust resistant device with protection against water jets) Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously ...

Page 117

Dimensions (unit : mm) 4-φ4.3±0.3 Mounting hole +50 300 0 Lead Wire AWG24 UL1007 50±0 Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 59 50±0.3 29.7 4-φ4.5 25±0.5 (3) (3) (10) (unit ...

Page 118

DC Fans Splash Proof Fan "San Ace 80W" W type General specifications IP55 (Dust resistant device with protection against water jets) Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in ...

Page 119

Dimensions (unit : mm) 8−φ4.3±0.3 Mounting hole Lead Wire AWG24 UL1007 +30 300 0 (250) 71.5±0.3 80±0.5 Reference dimension of mounting holes and vent opening (unit : mm) Air inlet side・Air outlet side 71.5±0.3 4- φ 4.5 78 25±0.5 3.5±0.3 ...

Page 120

DC Fans Splash Proof Fan "San Ace 80W" WP type General specifications IP55 (Dust resistant device with protection against water jets) Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously ...

Page 121

Dimensions (unit : mm) 4-φ4.3±0.3 Mounting hole +30 300 0 (10) Lead Wire AWG24 71.5±0.3 UL1007 80±0.5 Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 71.5±0.3 4-φ4.5 78.5 25±0.5 (3) (3) (unit : mm) 80 ...

Page 122

DC Fans Splash Proof Fan General specifications IP54 (Dust resistant device with protection against water spray) Material ‥‥‥‥‥‥‥‥‥Frame, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor ...

Page 123

Dimensions (unit : mm) 4−φ4.3±0.3 Mounting hole +30 300 0 (10) Lead Wire (4) AWG24 71.5±0.3 UL1007 80±0.5 Reference dimension of mounting holes and vent opening (unit : mm) Air inlet side・Air outlet side 71.5±0.3 4- φ 4.5 78 (4) ...

Page 124

DC Fans Splash Proof Fan “San Ace 92W” W type General specifications IP55 (Dust resistant device with protection against water jets) Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in ...

Page 125

Dimensions (unit : mm) 8ーφ4.3±0.3 3.5±0.4 Mounting hole Lead Wire AWG24 UL1007 +30 300 0 (10) (250) 82.5±0.3 92±0.5 Reference dimension of mounting holes and vent opening (unit : mm) Air outlet side 82.5±0.3 4- φ 4.5 90 25±0.5 3.5±0.4 ...

Page 126

DC Fans Splash Proof Fan General specifications IP54 (Dust resistant device with protection against water spray) Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air ...

Page 127

Dimensions (unit : mm) 4−φ4.3±0.3 Mounting hole +30 300 0 (10) Lead Wire (4) 82.5±0.3 AWG24 25±0.5 UL1007 92±0.5 Reference dimension of mounting holes and vent opening (unit : mm) Air inlet side・Air outlet side 4- φ 4.5 89 (4) ...

Page 128

DC Fans Splash Proof Fan “San Ace 120W” W type General specifications IP55 (Dust resistant device with protection against water jets) Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in ...

Page 129

Dimensions (unit : mm) 8-φ4.3±0.3 Mounting hole Lead Wire AWG24 UL1007 +30 300 0 (250) (10) 104.8±0.3 6.5±0.3 119±0.8 Reference dimension of mounting holes and vent opening (unit : mm) Air inlet side・Air outlet side 4-φ4.5 104.8±0.3 117 6.5±0.3 38±0.5 ...

Page 130

DC Fans Splash Proof Fan "San Ace 120W" WP type General specifications IP55 (Dust resistant device with protection against water jets) Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously ...

Page 131

Dimensions (unit : mm) 4-φ4.3±0.3 Mounting hole (10) +30 300 0 Lead Wire AWG24 UL1007 104.8±0.3 119±0.8 Reference dimension of mounting holes and vent opening Air outlet side Air inlet side 104.8±0.3 4-φ4.5 104.8±0.3 117 (5) (5) 38±0.5 (unit : ...

Page 132

DC Fans Splash Proof Fan "San Ace 120W" G type General specifications IP55 (Dust resistant device with protection against water jets) Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in ...

Page 133

Air Flow and Static Pressure Characteristics J speed G speed 180 280 260 13.8 V/27.6 V/55.2 V 160 240 220 140 13.8 V/27.6 V/55.2 V 200 12 V/24 V/48 V 120 180 12 V/24 V/48 V 160 100 10.2 V/20.4 ...

Page 134

DC Fans Splash Proof Fan General specifications IP54 (Dust resistant device with protection against water spray) Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air ...

Page 135

Dimensions (unit : mm) 4ーφ4.3±0.3 Mounting hole (10) +30 300 0 Lead Wire AWG24 UL1007 104.8±0.3 119±0.8 Reference dimension of mounting holes and vent opening (unit : mm) Air inlet side・Air outlet side 4-φ4.5 104.8±0.3 117 (6) (6) 38±0.5 120 ...

Page 136

DC Fans Splash Proof Fan "San Ace 140W" W type General specifications IP55 (Dust resistant device with protection against water jets) Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in ...

Page 137

Dimensions (unit : mm) 8-φ4.3±0.3 38±0.5 +30 Mounting hole 300 0 (250) (10) Lead Wire AWG24 UL1007 6±0.4 124.5±0.5 (4) 140±0.8 38mm thick 8-φ4.3±0.3 +30 Mounting hole 300 0 (250) (10) Lead Wire AWG24 UL1007 124.5±0.5 140±0.8 51mm thick Reference ...

Page 138

136 ...

Page 139

COOLING SYSTEMS DC FAN Domain diagram Air flow (m 3 /min) Frame size 0.1 0.2 0.3 0.4 40 □ □ 120 □ mm Oil Proof Fans 0.5 0.6 0.7 0.8 0.9 1.0 2.0 3 ...

Page 140

DC Fans Oil Proof Fan General specifications The product can be used in an oil mist environment Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free ...

Page 141

Dimensions (unit : mm) +1 4−φ3.5±0.3 40  0 32±0.3 Mounting hole +30 300  0 (10) Lead Wire AWG24 UL1430 Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 39 32±0.3 4-φ3.7 (15) 20±0.5 (4) (4) (unit ...

Page 142

DC Fans Oil Proof Fan General specifications The product can be used in an oil mist environment Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free ...

Page 143

Dimensions (unit : mm) +1 60  0 4−φ4.3±0.3 50±0.3 Mounting hole +50 300  0 Lead Wire AWG24 UL1430 Reference dimension of mounting holes and vent opening Air inlet side・Air outlet side 59 50±0.3 29.7 4-φ4.5 25±0.5 (3) (3) (10) (unit ...

Page 144

DC Fans Oil Proof Fan General specifications The product can be used in an oil mist environment Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free ...

Page 145

Dimensions (unit : mm) 4−φ4.3±0.3 Mounting hole (10) +30 300  0 Lead Wire AWG24 UL1430 104.8±0.3 119±0.8 Reference dimension of mounting holes and vent opening Air outlet side Air inlet side 104.8±0.3 4-φ4.5 104.8±0.3 117 (5) (5) 38±0.5 (unit : ...

Page 146

144 ...

Page 147

COOLING SYSTEMS DC FAN Domain diagram Air flow (m 3 /min) Frame dimensions 0.1 0.2 0.3 0.4 40 □ □ □ mm □ 120 □ mm 140 □ mm φ 172 mm ...

Page 148

DC Fans Long Life Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 149

Dimensions (unit : mm) Lead Wire AWG26 UL1007 Reference dimension of mounting holes and vent opening (unit : mm) Air inlet side・Air outlet side 40 mm 147 ...

Page 150

DC Fans Long Life Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 151

Dimensions (unit : mm) 8-φ4.3±0.3 Mounting hole +50 300 0 (10) Lead Wire AWG24 50±0.3 UL1007 + Reference dimension of mounting holes and vent opening (unit : mm) Air inlet side・Air outlet side 59 50±0.3 29.7 4-φ4.5 25±0.5 ...

Page 152

DC Fans Long Life Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 153

Dimensions (unit : mm) 8−φ4.3±0.3 Mounting hole 25±0.5 80±0.5 3.5±0.3 71.5±0.3 +50 300 0 (10) Lead Wire AWG24 UL1007 Reference dimension of mounting holes and vent opening (unit : mm) Air outlet side Air inlet side 4-φ4.5 71.5±0.3 78 3.5±0.3 ...

Page 154

DC Fans Long Life Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 155

Dimensions (unit : mm) 8ーφ4.3±0.3 Mounting hole 25±0.5 92±0.5 3.5±0.3 3.5±0.3 82.5±0.3 Lead Wire AWG24 UL1007 +30 300 0 (10) Reference dimension of mounting holes and vent opening (unit : mm) Air outlet side 82.5±0.3 4- φ 4.5 90 Air ...

Page 156

DC Fans Long Life Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 157

Dimensions (unit : mm) 8−φ4.3±0.3 Mounting hole 6.5±0.3 119±0.8 104.8±0.3 3.5±0.3 +30 300 0 (10) Lead Wire AWG24 UL1007 Standard type Reference dimension of mounting holes and vent opening (unit : mm) Air inlet side・Air outlet side 104.8±0.3 4-φ4.5 117 ...

Page 158

DC Fans Long Life Fan "San Ace 120L" G Type General specifications Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking ...

Page 159

Air Flow and Static Pressure Characteristics J speed G speed 280 180 260 13.8V/27.6V/55.2V 160 240 13.8V/27.6V/55.2V 220 12V/24V/48V 140 200 12V/24V/48V 10.2V/20.4V/40.8V 120 180 10.2V/20.4V/40.8V 160 100 140 120 80 100 ...

Page 160

DC Fans Long Life Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 161

Dimensions (unit : mm) 8−φ4.3±0.3 Mounting hole 140±0.8 124.5±0.5 6±0.4 +30 300 0 (10) Lead Wire AWG24 UL1007 38mm thick Reference dimension of mounting holes and vent opening (unit : mm) Air inlet side Air outlet side 124.5±0.3 4-φ4.5 138 ...

Page 162

DC Fans Long Life Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 163

Dimensions (unit : mm) 4-φ4.5±0.3 Mounting hole Lead Wire AWG24 UL1007 7.5±0.4 150±0.8 Reference dimension of mounting holes and vent opening (unit : mm) Air inlet side・Air outlet side 148 2-φ4.5 9.5 7.5±0.4 51±0.8 172 mm 161 ...

Page 164

DC Fans Long Life Fan General specifications Material ‥‥‥‥‥‥‥‥‥Frame:Aluminum, Impeller:Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 165

Dimensions (unit : mm) 8-φ4.5±0.3 Mounting hole Lead Wire AWG24 UL1007 7.5±0.4 (162±0.5) Reference dimension of mounting holes and vent opening (unit : mm) Air inlet side・Air outlet side 162±0.3 4-φ4.5 9.5 7.5±0.4 51±0.8 172 mm 163 ...

Page 166

164 ...

Page 167

COOLING SYSTEMS DC FAN Domain diagram Air flow (m 3 /min) Frame dimensions 0.1 0 120 mm 127 mm 150 mm 160 mm 0.3 0.4 0.5 0.6 0.7 0 ...

Page 168

DC Fans Blower General specifications Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 169

Dimensions (unit : mm) 51±1 20±0.3 18±0.3 φ36±1 2−φ4.5±0.3 (8) (6) (1.2) 24.7±1 Lead Wire 15±0.5 AWG26 UL1061 (2) 167 ...

Page 170

DC Fans Blower General specifications Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 171

Dimensions (unit : mm) 20mm thick 70.2±1 20±1 31±0.3 26±0.3 2-φ4.5±0.3 φ44±1 (10) (12) (1.2) 32.1±1 25mm thick 75.7±1 24.1±0.3 21.6±0.3 φ50.5±1 2−φ4.5±0.3 (10) (10) (2) 38.1±1 Lead Wire AWG26 UL3265 (1.2) Lead Wire 25±1 AWG24 UL1007 ( ...

Page 172

DC Fans Blower General specifications Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 173

Dimensions (unit : mm) 76±1 (2.5) Lead Wire AWG24 UL1007 (38) 24.1±0.3 30±0.5 (10) (10) (2) AIR FLOW 2−φ4.5±0.3 21.6±0 171 ...

Page 174

DC Fans Blower General specifications Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 175

Dimensions (unit : mm) 93.4±1 42.4±0.3 37.4±0.3 φ55±1 2−φ4.5±0.3 (10) (15) (1.8) 46.8±1 Lead Wire AWG24 29.8±1 UL1007 (3.5) 173 ...

Page 176

DC Fans Blower "San Ace" B97 High Air Flow Type General specifications Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ...

Page 177

Dimensions (unit : mm) 97.1±1 32±0.3 26±0.3 4-φ4.5±0.3 0.5±0.3 (10) (20) 31.5±0.3 50±1 39±0.3 Lead Wire AWG24 (5) UL3266 (2) (2) 33± 175 ...

Page 178

DC Fans Blower General specifications Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 179

Dimensions (unit : mm) 97.2±1 39±0.3 32±0.3 φ55±1 2−φ4.5±0.3 (2) (10) ( 15) 50±1 Lead Wire AWG24 33±1 UL1007 (4) 177 ...

Page 180

DC Fans Blower General specifications Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 181

Dimensions (unit : mm) ︶ ︵ (5) (15) 88±0.3 +30 300 0 32±0.5 AIR FLOW 104.8±0.5 120±1 Lead Wire AWG24 UL1007 120 mm 179 ...

Page 182

DC Fans Blower General specifications Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 183

Dimensions (unit : mm) Lead Wire AWG24 UL1007 124±1 (50.4) (3.5) 5±0.5 111.9±0.5 +1 126±1 32.0 (62) (2) (12) (10) AIR FLOW (54.4) 6−φ4.3±0.3 104.8±0.5 127 mm 181 ...

Page 184

DC Fans Blower General specifications Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 185

Dimensions (unit : mm) 150±1 47±0.3 58.5±0.3 38±1 13.7±1 2-φ4.5±0.3 2-R4.2±0.3 12.5±1 17.7±1 8±1 60±1 49±1 74±1 40±1 Lead Wire AWG24 UL3266 SANYO DENKI (1.7) 36.3±1 (2) 150 mm 183 ...

Page 186

DC Fans Blower General specifications Material ‥‥‥‥‥‥‥‥‥Frame, impeller : Plastics Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current blocking function (with reverse polarity protection) ...

Page 187

Dimensions (unit : mm) Lead Wire AWG24 UL1007 (46.6) (6) 6±0.5 144.2±0.5 (160) 40±1 (80.2) 16 (2) (2) AIR FLOW (73.3) 135.2±0.5 3−φ4.8 3−φ4.3 185 160 mm ...

Page 188

186 ...

Page 189

COOLING SYSTEMS DC FAN Domain diagram Air flow (m 3 /min) Frame size 0.1 ø 220 mm Centrifugal Fans 15.0 16.0 17.0 18.0 71 19.0 20.0 Conversion table 200 mm 187 ...

Page 190

DC Fans Centrifugal Fan General specifications Material ‥‥‥‥‥‥‥‥‥Impeller : Plastic Attachment base:Aluminum Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously run in a free air state) Motor Protection System ‥‥Current cut function (with reverse ...

Page 191

Dimensions (unit : mm) 71±1 Rotation 64±1 Note : Depth of mounting screw 6mm Max. Reference Dimension of Inlet Ring (unit : mm) (φ155) With Inlet Ring Note : Please contact us if you need further information. Lead Wire AWG22 ...

Page 192

190 ...

Page 193

COOLING SYSTEMS Liquid Cooling Solution Systems SAN ACE MC-HX 9H9912G5016 SAN ACE MC 109X9412S1016 SAN ACE MC 109X7612H1176 SAN ACE MC 109X9612S5016 SAN ACE MC 109X7412S4016 Intel ® Pentium SAN ACE MC 109X6512A2016 2002 2003 CPU Coolers SAN ACE MC-HX ...

Page 194

DC Fans CPU Cooler ® For Intel 775 land-LGA Package CPU Cooler " SAN ACE MC" Thermal Module (Type I) for BTX General specifications Material ‥‥‥‥‥‥‥‥‥Frame,Impeller,Duct:Plastics Duct sael:Rubber sponge Heatsink:Aluminum (Core:Copper) Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% ...

Page 195

Dimensions (unit : mm) Lead Wire AWG26 UL1430 No.6-32 Screw(4PCS) 111.8±2 98±1.5 (3.5) 123±2 (20) 85.5±1.5 5.2±1 (Heat Sink Base To Duct) 92.3±1.5 95.5±1.5 Thermal Pad Honeywell PCM45F 193 775-lamd LGA ...

Page 196

DC Fans CPU Cooler ® For Intel 775-land LGA Package CPU Cooler " SAN ACE MC" PWM Control Function and Thermally Speed Control General specifications Material ‥‥‥‥‥‥‥‥‥Frame,impeller:Plastics Heatsink:aluminum (Core:copper) Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, ...

Page 197

Dimensions (unit : mm) 62.6±1 320±10 Lead Wire AWG26 UL1430 Thermal pad 72.1±0.5 Honeywell PCM45F 775-lamd LGA 195 ...

Page 198

DC Fans CPU Cooler ® ® For Intel Pentium 4 Processor (775-land LGA Package) CPU Cooler " SAN ACE MC" PWM Control Function and Thermally Speed Control General specifications Material ‥‥‥‥‥‥‥‥‥Frame,impeller:Plastics Heatsink:aluminum (Core:copper) Life Expectancy ‥‥‥‥‥Varies for each model (Survival ...

Page 199

Dimensions (unit : mm) 62.6±1 310±10 Lead Wire AWG26 UL1430 (φ96.8) 72.1±0.5 THERMAL PAD Honeywell PCM45F 775-lamd LGA 197 ...

Page 200

DC Fans CPU Cooler ® ® For Intel Pentium 4 Processor (Socket 478) CPU Cooler " SAN ACE MC" General specifications Material ‥‥‥‥‥‥‥‥‥Frame,impeller:resin mold Heatsink:aluminum (Core:copper) Life Expectancy ‥‥‥‥‥Varies for each model (Survival rate: 90% at 60℃, rated voltage,and continuously ...

Related keywords