W1G200-HH01-52 EBM-Papst Industries Inc, W1G200-HH01-52 Datasheet - Page 5

DC Tubeaxial Fans

W1G200-HH01-52

Manufacturer Part Number
W1G200-HH01-52
Description
DC Tubeaxial Fans
Manufacturer
EBM-Papst Industries Inc
Series
W1G200Hr
Datasheets

Specifications of W1G200-HH01-52

Power (watts)
45.0W
Size / Dimension
Square - 225mm L x 225mm H x 80mm W
Termination
Terminal Block
Fan Type
Tubeaxial
Termination Style
61 dB(A)
Air Flow
588.0 CFM (16.65m³/min)
Bearing Type
Ball
Voltage - Rated
48VDC
Weight
4.7 lbs (2.1kg)
Voltage Range
36.0 ~ 57.0VDC
Operating Temperature
-13 ~ 140°F (-25 ~ 60°C)
Life Expectancy
57000 hrs @ 40°C
Rpm
2750 RPM
Noise
60 dB(A)
Product
Fans
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Static Pressure
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
W1G200HH0152
4. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REME-
Do not perform any repairs on your device. Return the fan to ebm-papst for repair
or exchange.
4.1 Safety examination
What has to be tested?
Protective casing against
accidental contact
Fan for damage
Mounting of fan
Mounting of connecting cables
Mounting of protective earth
connection
Insulation of the cables
Malfunction/error Possible cause
Motor does not
turn
Impeller running
roughly
Overtemperature
of electronics
Overtemperature
of motor
Incorrect rotor
position detection
DIES
WARNING
Terminals and connections have voltage even in a unit that is
shut off
Electric shock
➜ Wait five minutes after disconnecting the voltage at all poles
CAUTION
If control voltage is applied or a speed setpoint is stored,
the motor automatically restarts, e.g. after a power failure.
Danger of injury
Keep out of the danger zone of the device.
➜ When working on the device, switch off the mains supply voltage
➜ Wait until the device stops.
If the device remains out of use for some time, e.g. when in storage,
we recommend switching the device on for at least 2 hours to allow
any condensate to evaporate and to move the bearings.
If you have any other problems, contact ebm-papst.
before touching the unit.
and secure the latter from being switched on again.
Mechanical blockage
– Mains supply voltage
– Imbalance in rotating
– Ambient temperature
– Insufficient cooling
– Unacceptable opera-
– Failure of electronics
faulty
parts
too high
ting point
(not applicable to DC-
fed devices)
How to test?
Visual inspection
Visual inspection
Visual inspection
Visual inspection
Visual inspection
Visual inspection
Possible remedy
– Switch it off and remove
– Check mains supply voltage,
– Apply control signal
– Clean the device; if imbalan-
– Lower ambient temperature
– Reset by reducing control
mechanical blockage
restore power supply
ce still evident after clea-
ning, replace device
if possible.
input to 0.
Frequency
At least every 6 months
At least every 6 months
At least every 6 months
At least every 6 months
At least every 6 months
At least every 6 months
5/5