PH150MLI HAMMOND POWER SOLUTIONS, PH150MLI Datasheet - Page 12

no-image

PH150MLI

Manufacturer Part Number
PH150MLI
Description
Control Transformer
Manufacturer
HAMMOND POWER SOLUTIONS
Type
Controlr
Datasheets

Specifications of PH150MLI

Transformer Type
Control
Input Voltage
480V
Current Rating
1.3A
Power Rating
150VA
Transformer Mounting
Chassis
Secondary Current Nom
6.25A
Primary Voltages
480/240, 460/230/208, 440/220/200
Brand/series
Imperator™ Series
Configuration
Encapsulated
Current, Secondary
1.3/6.25 A
Dimensions
5.44"L×4"W×3.81"H
Frequency
50/60 Hz
Mounting Hole Centers
3.38, 2.75 "
Number Of Outlets
2
Phase
1
Power, Rating
150 VA
Standards
cULus, CE
Temperature, Operating
+55 °C
Termination
Screw Terminals
Voltage, Primary
460/230/208 VAC
Voltage, Secondary
115/24 VAC
Output Voltage
120V
Secondary Voltages
120/25, 115/24, 110/23
Rohs Compliant
Yes
External Height
96.77mm
Weight
7.6lb
External Depth
138.18mm
External Width
101.6mm
11
Optional Unfused Finger Guard Kits
Optional Fused Finger Guard Kits
Note: Each finger guard kit supplies either the primary or secondary side.
Kit Part
Number
FG1
FG2
FG2
FG2
FGF1
FGF2
FGF2
FGF2
FG3
FG3
FG3
FG4
FG4
FG4
FG5
FG5
Factory Installed Primary and Secondary Fuse Kits
HPS now stocks some HPS Imperator series voltage groups with FACTORY INSTALLED primary and secondary
fuse clips. To order, just add the suffix “-FK” to the end of the standard part number.
Factory installed primary and secondary fuse clips are only available on the following voltage groups:
Group C (p/n: PH***MQMJ-FK) | Group G (p/n: PH***PG-FK) | Group I (p/n: PH***MLI-FK)
On PH750PG-FK, PH1000PG-FK, PH750MLI-FK, and PH1000MLI-FK, only primary fuse clips are included on
factory installed units. Secondary fuse clips are not included or available on these units.
Note:
a different primary or secondary voltage, please refer to the wiring instruction sheet included with the transformer.
All factory installed fuse kits are pre-wired at the transformers highest primary voltage and the lowest secondary voltage. To hook up at
AJ, AR, MQMJ, MEMX, QR, SP, PG, PP
MBMH, MGJ, MLI
All
All
refer to FG3, FG4 or FG5 below
AJ, AR, MQMJ, MEMX, QR, SP, PG, PP
MBMH, MGJ, MLI
All
All
MBMH
All
AJ, AR, MQMJ, MEMX, QR, SP, PG, PP
MBMH, MGJ, MLI
All
AJ, AR, MQMJ, QR, SP, PP
MBMH, MEMX, MGJ, MLI, PG
All
(excluding PH100MBMH)
(excluding PH100MBMH)
Applicable Transformer
Part Number Suffix’s
Visit our website: www.hammondpowersolutions.com
50
50
75
100
150 to 1500
50
50
75
100
100
150
250
250
350, 500
750
750
1000, 1500
Applicable
VA Sizes
1 finger guard (unfused), PHAK1 instruction sheet
1 finger guard (unfused), PHAK1 instruction sheet
1 finger guard (unfused), PHAK1 instruction sheet
1 finger guard (unfused), PHAK1 instruction sheet
1 finger guard (fused), PHAK1 instruction sheet
1 finger guard (fused), PHAK1 instruction sheet
1 finger guard (fused), PHAK1 instruction sheet
1 finger guard (fused), PHAK1 instruction sheet
1 finger guard, PHAK1 instruction sheet
1 finger guard, PHAK1 instruction sheet
1 finger guard, PHAK1 instruction sheet
1 finger guard, PHAK1 instruction sheet
1 finger guard, PHAK1 instruction sheet
1 finger guard, PHAK1 instruction sheet
1 finger guard, PHAK1 instruction sheet
1 finger guard, PHAK1 instruction sheet
Parts Included in Kit

Related parts for PH150MLI