HS19F1B SOLA HEVI DUTY, HS19F1B Datasheet

Buck Boost Transformer

HS19F1B

Manufacturer Part Number
HS19F1B
Description
Buck Boost Transformer
Manufacturer
SOLA HEVI DUTY
Type
Buck-Boostr
Datasheets

Specifications of HS19F1B

Transformer Type
Buck Boost
Input Voltage
240V
Output Voltage
12V
Current Rating
83.3A
Power Rating
999.6W
Transformer Mounting
Wall
Secondary Current Nom
83.3A
Primary Voltages
2 X 120V
Capacity
1 kVA
Configuration
Encapsulated
Current, Secondary
83.3/41.6 A
Dimensions
6"W×10"H×5"D
Frequency
60 Hz
Number Of Outlets
2
Phase
1
Power, Rating
1000 VA
Standards
UL, cULus, CSA
Voltage, Primary
120/240 VAC
Voltage, Secondary
12/24 VAC
Secondary Voltages
2 X 12V
Peak Reflow Compatible (260 C)
No
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Buck-Boost Transformers
Buck-Boost transformers are small, single phase, dry type
distribution transformers designed and shipped as
insulating/isolating transformers. They have a dual voltage
primary and a dual voltage secondary. These transformers
can be connected for a wide range of voltage combinations.
The most common use is to buck (lower) or boost (raise) the
supply voltage a small amount, usually 5 to 27%. Buck-
Boost transformers are in compliance with NEC Article 210-9,
Exception 1 when field connected as an autotransformer.
The major advantages of Buck-boost transformers are their
low cost, compact size and light weight. They are also more
efficient and cost less than equivalent isolation transformers.
When connected as an autotransformer, they can handle
loads up to 20 times the nameplate rating. A buck-boost
transformer is the ideal solution for changing line voltage by
small amounts.
On this page:
When a buck-boost has the primary and secondary windings connected, per recommended instructions,
it becomes an autotransformer. Now only the secondary windings are transforming voltage and current.
The majority of the KVA load passes directly from the supply to the load. This is why buck-boost
transformers can supply a load with a much larger KVA rating than the nameplate indicates.
Ideal for low voltage lighting control applications
Sola/Hevi-Duty buck-boost transformers are designed to supply power to low voltage lighting circuits,
control panels or other systems requiring 12, 16, 24, 32, or 48 Volts. When connected as an insulating
transformer (by following the wiring diagram on the inside of the transformer case), the transformer's
capacity matches the nameplate KVA rating.
Sola/Hevi-Duty buck-boost transformers are also suited for low voltage landscape lighting. They are UL
listed for outdoor service and their compact size makes them the perfect solution for providing power to
accent lighting applications.
When using dimmers for low voltage applications, use only dimmers designed and rated for use with
magnetic loads. We strongly recommend contacting the dimmer manufacturer for advice on your
specific lighting application.
Applications
Selection Steps
1.
2.
Input Line Voltage
Measure the supply voltage with a voltmeter.
Voltage Required for the Load
Check the load equipment to determine the voltage requirement.
Selection
Steps,
Fusing Buck-Boost
Transformers, Applications,
Accessories

Related parts for HS19F1B

HS19F1B Summary of contents

Page 1

... Now only the secondary windings are transforming voltage and current. The majority of the KVA load passes directly from the supply to the load. This is why buck-boost transformers can supply a load with a much larger KVA rating than the nameplate indicates. Applications ...

Page 2

... For determining the correct size of breaker or fuse for a given range of input or output ampere ratings, refer to Section 450-4, of the National Electric Code (NEC). "450-4, Autotransformers 600 Volts, Nominal or Less. (a) Overcurrent Protection. Each autotransformer 600 volts, nominal or less shall be protected by an individual overcurrent device installed in series with each ungrounded input conductor ...

Page 3

... HS19B100 0.15 12.5 HS19B150 0.25 20.8 HS19B250 0.5 41.6 HS19F500B 0.75 62.5 HS19F750B 1 83.3 HS19F1B 1.5 125 HS19F1.5A 2 166.6 HS19F2A 3 250 HS19F3A 5 416.5 HS19F5A 7.5 625 HS19F7.5A Group 2 – 120 x 240 Volt Primary, 16/32 Volt Secondary Maximum Secondary Amperage ...

Page 4

... Connect Interconnect Voltage Lines To 240 & 120 H1 & Secondary Connect Interconnect Voltage Lines & 12-0-12 X1-X2- & HS19 and S19 Series 216 Buck–Boost Transformers Height Width (inch) (inch Non-Encapsulated - 50/60 Hz, Single Phase 3. 5 Encapsulated - 60 Hz, Single Phase 62.5 ...