12C SUPERIOR ELECTRIC, 12C Datasheet

Variable Transformer

12C

Manufacturer Part Number
12C
Description
Variable Transformer
Manufacturer
SUPERIOR ELECTRIC
Type
Variabler
Datasheets

Specifications of 12C

Input Voltage
240V
Output Current
0.7A
Knob Rotation
CW / CCW
Transformer Mounting
Panel
Secondary Current Nom
0.7A
No. Of Phases
Single
Primary Voltages
240V
Power Rating
0.17kVA
Brand/series
Powerstat®/12C Series
Configuration
Open Frame
Current, Secondary
0.7/0.5 A
Dimensions
2.06"L×2.81"Dia.
Frequency
50/60 Hz
Mounting Type
Panel/Chassis
Number Of Outlets
1
Phase
1
Power, Rating
0.17/0.13 kVA (Constant Current Load), 0.22 kVA (Constant Impedance Load)
Termination
Quick-Connect
Voltage, Primary
240 VAC
Voltage, Secondary
0-240/0-264 VAC
Constant Current Load
70mA
Rohs Compliant
Yes
Current Rating
0.7A
Output Voltage
240V
Output Voltage Max
240VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
12C1
Manufacturer:
ST
0
Part Number:
12C2
Manufacturer:
ST
0
Part Number:
12C3
Manufacturer:
ST
0
Part Number:
12C508
Manufacturer:
ST
0
Part Number:
12C508
Manufacturer:
ST
Quantity:
20 000
Part Number:
12C508-04/SM
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
12C508-SN
Manufacturer:
SN
Quantity:
20 000
Part Number:
12C508/P
Manufacturer:
MICROCHIP
Quantity:
5 510
Part Number:
12C508/P
Manufacturer:
LITTLEFUSE
Quantity:
5 510
Part Number:
12C508A
Manufacturer:
SAWTEK
Quantity:
350
Part Number:
12C508A-04/P
Manufacturer:
MIC
Quantity:
6 259
Part Number:
12C508A-04/PHBP
Manufacturer:
AMSI
Quantity:
6 229
Part Number:
12C508A-04/SM
Manufacturer:
NS
Quantity:
100
Part Number:
12C508A-04/SM
Manufacturer:
MICREL/麦瑞
Quantity:
20 000
Part Number:
12C508A04
Manufacturer:
MIC
Quantity:
20 000
Your new POWERSTAT Variable Transformer has been carefully packed for
shipment. However, damage may occur in transit. After receiving a unit,
check all components (brush contact primarily) to satisfy yourself that there
is no damage. Also make sure that the dial, knob, lock-washer and mounting
nuts are in the package. The “Damage and Shortage” Instructions packed
with the unit outline the proper procedure to follow if any parts are damaged
or missing.
POWERSTAT Variable Transformers of the 10C, 10C-40 and 12C Series are
designed for mounting in the back-of-panel position only.
The single hole mounting of single units is fast and simple. For keying to the
panel, a 1/16 inch projection is provided. To facilitate mounting, a drilling
template is supplied as part of these instructions. Actually, the drilling template
must be used only when the hole for the 1/16 inch projection is required.
on all products is reserved.
28 SPRING LANE • SUITE 3 • FARMINGTON, CT 06032 USA
ECN 96200
002105-280 REV G
engineering refinements
Dimensions and other
details are subject to
PANEL DRILLING TEMPLATE
The right to make
change.
www.superiorelectric.com
(Viewed from Knob End)
for INSTALLATION OPERATION and MAINTENANCE
INSTRUCTIONS
Single Units
INSTALLATION
INSPECTION
Single Units
POWERSTAT
VARIABLE TRANSFORMERS
10C, 10C-40 and 12C Series
Telephone and Fax Numbers
Telephone
Fax
Customer Service
Product Application
860-507-2025
860-507-2050
860-507-2025, Ext. 70782
860-507-2025, Ext. 72058
To mount, proceed as follows:
Ganged units require four panel holes for mounting. Three are needed
for the mounting bolts and a clearance hole is necessary for the center
shaft.
To mount, proceed as follows:
When installed and operated in accordance with these instructions, a
POWERSTAT Variable Transformer should require no servicing except
possible replacement of the brush assembly. The brushes should be
inspected periodically and replaced if arcing takes place or if they are
badly worn. Use only the correct Superior Electric replacement brush
assembly. The brushes must be of a special material if proper operation
is to be attained.
Whenever unusual mechanical or electrical difficulties are encountered
in the installation or operation of your POWERSTAT Variable Transformer,
consult Superior Electric.
1. Using the drilling template, locate the panel holes. In order for the
2. Mount the POWERSTAT Variable Transformer as shown. Mount the
3. If the unit is not to be keyed to the panel, only the hole for the 3/8
1. Using the drilling template, locate the four panel holes. If the template
2. Mount the unit behind the panel as shown using the three ¼”-20
terminals to be on top, the template should be upright. Drill the
holes.
unit flush to the back of the panel and the dial flush to the front. A
single nut and lockwasher hold the unit and dial in place. The knob,
when mounted on the shaft, covers the nut and lockwasher.
inch center shaft should be drilled. The extra nut provided is placed
on the shaft between the unit and the back of the panel. Otherwise
the mounting is as explained above.
is upright the terminals will not be directly on top. When terminals
are required at the top, line marked “T” should be vertical. Drill the
holes.
mounting bolts provided. Mount the dial on the front panel, securing
it in place with the 3/8” -32 nut and lockwasher provided. The knob,
when mounted on the shaft covers the nut and lockwasher
REPLACEMENT BRUSH
Note: 10C and 12C Replacement Brush Assembly are the same.
10C-40
TYPE
10C
12C
REPLACEMENT BRUSH ASSEMBLIES
MAINTENANCE
ASSEMBLIES
Ganged Assemblies
Toll-Free (in USA and Canada only)
Telephone
Fax
Customer Service
Product Application
030098-001
030098-004
030098-001
PART NO.
®
RB10C-40/RB10B-40
DESCRIPTION
RB10C/RB10B
1-800-787-3532
1-800-821-1369
1-800-787-3532, Ext. 70782
1-800-787-3532, Ext. 72058
RB12C
Printed in USA