EVAL-ADXL325Z Analog Devices Inc, EVAL-ADXL325Z Datasheet - Page 12

no-image

EVAL-ADXL325Z

Manufacturer Part Number
EVAL-ADXL325Z
Description
Accelerometer Eval. Board
Manufacturer
Analog Devices Inc
Series
iMEMS®r
Datasheets

Specifications of EVAL-ADXL325Z

Silicon Manufacturer
Analog Devices
Application Sub Type
Accelerometer - Three-Axis
Kit Application Type
Sensing - Motion / Vibration / Shock
Silicon Core Number
ADXL325
Sensor Type
Accelerometer, 3 Axis
Sensing Range
±6g
Interface
Analog
Sensitivity
174mV/g
Voltage - Supply
1.8 V ~ 3.6 V
Embedded
*
Utilized Ic / Part
ADXL325
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
ADXL325
Self test response in g is roughly proportional to the square of
the supply voltage. However, when ratiometricity of sensitivity
is factored in with supply voltage, the self test response in volts
is roughly proportional to the cube of the supply voltage.
For example, at V
ADXL325 is approximately −328 mV for the X-axis, +328 mV
for the Y axis, and +553 mV for the Z axis. At V
test response is approximately −56 mV for the X axis, +56 mV
for the Y axis, and −95 mV for the Z axis.
The supply current decreases as the supply voltage decreases.
Typical current consumption at V
typical current consumption at V
S
= 3.6 V, the self test response for the
X
Y
Z
OUT
OUT
OUT
= 0 g
= 1 g
= 0 g
S
S
= 2 V is 300 μA.
= 3.6 V is 375 μA, and
TOP
Figure 24. Output Response vs. Orientation to Gravity
S
X
Y
Z
= 2 V, the self
X
Y
Z
OUT
OUT
OUT
OUT
OUT
OUT
TOP
TOP
= 1 g
= 0 g
= 0 g
= –1 g
= 0 g
= 0 g
Rev. 0 | Page 12 of 16
TOP
X
Y
Z
X
Y
Z
OUT
OUT
OUT
OUT
OUT
OUT
AXES OF ACCELERATION SENSITIVITY
Figure 23. Axes of Acceleration Sensitivity (Corresponding Output Voltage
= 0 g
= –1 g
= 0 g
= 1 g
= 0 g
= 0 g
A
Z
Increases When Accelerated Along the Sensitive Axis)
GRAVITY
X
Y
Z
OUT
OUT
OUT
= 0 g
= 0 g
= –1 g
A
Y
A
X

Related parts for EVAL-ADXL325Z