NP100-12 EnerSys, NP100-12 Datasheet

no-image

NP100-12

Manufacturer Part Number
NP100-12
Description
LEAD ACID BATTERY, 12V, 100AH
Manufacturer
EnerSys
Datasheet

Specifications of NP100-12

Battery Capacity
100Ah
Battery Voltage
12V
Battery Technology
Lead Acid
External Height
214mm
External Width
174mm
External Depth
329mm
Weight
72.62lb
Battery Terminals
Bolt
Height
8.43"
Lead Free Status / RoHS Status
na
NOMINAL VOLTAGE: 12V
NOMINAL CAPACITY:
WEIGHT (approx.): 68 pounds (30.8kgs)
ENERGY DENSITY (20 hr. rate):
SPECIFIC ENERGY (20 hr. rate):
INTERNAL RESISTANCE OF CHARGED
BATTERY:
MAXIMUM DISCHARGE CURRENT
MAXIMUM SHORT-DURATION
OPERATING TEMPERATURE RANGE:
WITH STANDARD TERMINALS:
DISCHARGE CURRENT:
1.45 WH/cubic inch (90 WH/liter)
16.5 WH/pound (36 WH/kg)
5.1 milliohms (approx.)
150 amperes
500 amperes
CHARGE
DISCHARGE -4
20 hr. rate of
10 hr. rate of 8.06A to 10.5V 80.6Ah
5 hr. rate of 15.4A to 10.2V 77.2Ah
1 hr. rate of 62.6A to 9.60V 62.6Ah
S p e c i f i c a t i o n s
5
(-20
(-15
0
0
F to 122
F to 140
4.6A to 10.5V 91.6Ah
0
0
C to 60
C to 50
0
0
F
F
0
0
C)
C)
CHARGE RETENTION (shelf life)
LIFE EXPECTANCY:
100% depth of discharge
50% depth of discharge
30% depth of discharge
SEALED CONSTRUCTION:
STANDARD TERMINAL:
HOUSING MATERIAL: PP Resin
OPTIONAL:
STANDBY USE
CYCLE USE (approx.):
at 68˚F (20˚C):
1 month
3 months 91%
6 months 85%
Can be operated in any position
without leakage.
Universal or options
in terminal diagram
Container and cover made from
Flame Retardant PP
(UL94-V0/L.O.I.>28%)
97%
3 to 5 years
1200 cycles
250 cycles
550 cycles
Dimensions
DIMENSIONS: INCHES (MM)
Terminal
Note:
Dimensions are in inches (mm)
Tolerances are -
and -
dimensions.
Terminal height
above cover
Terminal
Type
MG
NB
MJ
AP
+
Standard
B
U
0.08 in. (-
U Positive
Terminal
U Negative
Terminal
21.1
26.9
21.1
36.3
21.1
mm
NP100-12
3.3
+
+
2mm) for height
0.04 in. (-
0.13
0.83
1.06
0.83
1.43
0.83
ins
Publication No: US-NP100-12-1 • July 2003
RECOGNIZED BY UL, File No. MH 14328
+
1mm)
NP100-12FR
Sealed Rechargeable
12V, 91.6Ah
Lead-Acid Battery
NP100-12
Automotive Type
NB Terminal
MG Positive
AP Positive
Optional
MJ Terminal
Automotive Type
MG Negative
AP Negative
NP
B Terminal

Related parts for NP100-12

NP100-12 Summary of contents

Page 1

... Terminal U Negative Automotive Type Automotive Type Terminal AP Positive AP Negative NP100-12 mm ins 3.3 0.13 21.1 0.83 NB Terminal B Terminal 26.9 1.06 21.1 0.83 36.3 1.43 21.1 0.83 + 0.04 in 1mm) + 2mm) for height MJ Terminal RECOGNIZED BY UL, File No. MH 14328 Publication No: US-NP100-12-1 • July 2003 ...

Page 2

... NUMBER OF CYCLES When the battery will be used by current in excess of 3C, consult with EnerSys, Inc. prior to use. CHARGING METHODS (At 20ºC) CAUTION •Avoid short circuit •Do not charge in a sealed container. EnerSys Inc. P.O. Box 14145 Reading, PA 19612-4145 ...

Related keywords