51V019S-33WN-BD MULTICOMP, 51V019S-33WN-BD Datasheet - Page 8

HDMI CONNECTOR, RECEPTACLE, 19POS, PCB

51V019S-33WN-BD

Manufacturer Part Number
51V019S-33WN-BD
Description
HDMI CONNECTOR, RECEPTACLE, 19POS, PCB
Manufacturer
MULTICOMP
Datasheet

Specifications of 51V019S-33WN-BD

Gender
Receptacle
No. Of Contacts
19
Contact Termination
Surface Mount Vertical
Connector Mounting
PCB
Contact Plating
Gold
Contact Material
Copper Alloy
Connector Type
HDMI
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
REV.
ITEM
10
7
8
9
Temperature Life
Refer to:
1. RS-364-17
Humidity
Refer to:
1.RS – 364 – 31
2.MIL – STD – 202F
3.MIL – STD – 1344A
Insertion Force &
Withdrawal Force
Refer to:
1.RS-364-37
2.MIL-STD-1344A-
Salt Spray
Refer to:
1.RS – 364 – 26
2.MIL – STD – 202F
3.MIL – STD – 1344A
ECN. NO.
TEST DESCRIPTION
103B
1002.2
2013.1
101D
1001.1
APPO.
Withdrawal force is
1.0~4.0kgf after 2,000
cycles and 0.5~4.0kgf
after 2001~10000 cycles
Appearance: No Damage
Contact resistance change
from initial requirement:
Contact: 30 milliohm
max.
Shell: 50 milliohm max.
Appearance: No Damage
Contact Resistance
change from initial
requirement:
Contact: 30 milliohm
maximum.
Shell: 50 milliohm
maximum
Appearance: No Damage
Contact resistance
change from initial
requirement:
Contact: 30 milliohm
maximum.
Shell: 50 milliohm
maximum
Insulation Resistance:
Must meet Item 3
Insertion force is 4.5kgf
maximum.
After the Salt Spray test ,
The connectors shall
meet the requirements of
contact resistance and
insulation resistance , etc.
REQUIREMENT
TITLE:
PART NO.
DOC NO. PSF-51S002
HDMI Receptacle
PI-3
51***S-****-*
A : Mate connectors together and repeat
the test specified in illustration up to 4
cycles. Upon completion of the test,
specimens shall be conditioned at ambient
room conditions for 24 hours, after which
the specified measurements shall be
preformed.
Temperature: +25 ~+85
Relative Humidity: 80%~95%
Duration: 4 cycles(96hours)
B : Unmate each connectors and repeat
the test specified in illustration up to 4
cycles. Upon completion of the test,
specimens shall be conditioned at ambient
room conditions for 24 hours, after which
the specified measurements shall be
preformed.
Temperature: +25 ~+85
Relative Humidity: 80%~95%
Duration: 4 cycles(96hours)
The specimen are mounted to mounting
fixtures by the normal mounting menas.
The peak force shall be recorded at the
maximum rate of 25
The connector specimen are testing with
the 5% Salt Water (NaC1) , 6.5 – 7.2 PH ,
for 48 hours of Salt Spray test.
Mate connectors and expose to 105
for 240 hours. Upon completion of the
exposure period, the test specimens shall
be conditioned at ambient room
conditions for 1 to 2 hours, after which
the specified measurements shall be
performed.
FREEPORT
PROCEDURE
APPO. Peterhu
CHKD. Peterhu
DR.
REV. 1
Winder Wang
SHEET 3/4
02/23/04
02/23/04
02/23/04

Related parts for 51V019S-33WN-BD