MC34931 MULTICOMP, MC34931 Datasheet

HDMI CONNECTOR, RECEPTACLE, 19POS, PCB

MC34931

Manufacturer Part Number
MC34931
Description
HDMI CONNECTOR, RECEPTACLE, 19POS, PCB
Manufacturer
MULTICOMP
Datasheet

Specifications of MC34931

Gender
Receptacle
No. Of Contacts
19
Contact Termination
Surface Mount Horizontal
Connector Mounting
PCB
Contact Plating
Gold
Contact Material
Copper Alloy
Connector Type
HDMI
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Sample Acceptance Level
Part Name
EDA Part No./Rev
Reason for Initial Sample:
Manufacturing Information:
Customer Information:
Results:
Meet all drawing and specification requirement
Submission Checklist:
Comments:
Declaration:
We Confirm that the samples represented by this Initial Sample Release are representive of our part and have been made to the applicable customer
drawing and specification from specified material.
Supplier Authorized Signature
Print Name :
For Customer Only
Part Disposition
Customer Name:
The results for 1. dimensional measurements
FREEPORT
Initial Submission
Engineer Change(s)
Change in Optional Construction or Material
Process Change
Additional, Replacement, or Refurbished Tooling
Checked Print
Auxiliary Drawing/Sketches
Correct Number of Samples
Dimensional Results
Control plan
Process Capability Results
Address
Address
Name
Name
This samples meet all drawing and specification requirement.
HDMI Receptacle SMT type without flange
51U019S-325N-AR-B
FREEPORT
Wusha the 6th Industrial Zone, Wu Sha Village, Chang-An Town,Dongguan City, Guangdong Province, China 523806
Peterhu
LEVEL 2
:
Peterhu
Initial Sample Release
Title: Engineer manager
Customer
Signature:
Approval
Change Subcontractor Source
Tooling tranfer
Correction of Discrepancy(Resubmission No.
Parts Produced of Addition Location
Other, please Specify
Yes
Process Flow Design
Gauge(Measurement) Studies
Material test Results
Certifications
(E.S) test Results
Product Engineering Approval
No
(see comment below)
Customer Part No.
Document No
Customer code
Vendor code
Application
Buyer
Date:
Phone No.: 86-769-85428686-2701
3. E.S tests
Reject
ISR080125-1
26-JAN-08
Date:
TITLE NO:RDD042
)

Related parts for MC34931

MC34931 Summary of contents

Page 1

FREEPORT HDMI Receptacle SMT type without flange Part Name 51U019S-325N-AR-B EDA Part No./Rev Reason for Initial Sample: Initial Submission Engineer Change(s) Change in Optional Construction or Material Process Change Additional, Replacement, or Refurbished Tooling Manufacturing Information: Name FREEPORT Address Wusha ...

Page 2

CUSTOMER PART NAME : HDMI receptacle SMT type without flange : 51U019S-325N-AR-B PART NO. CUSTOMER P/N MANUFACTURER SIGNATURE SALES REP. Jamie DATE 01/26/08 DATE 01/26/08 th Wusha the 6 Dongguan City, Guangdong Province, China 523806 Tel: 86-769-85428686 Document No. 51U019S-325N-AR-B ...

Page 3

Production Drawing 2. Sample Inspection Report 3. Production Specification 4. Reliability Test Report 5. Packing SPEC 6. SOP 7. Material Certification 9. X-ray Report 10. SGS Test Report 11. ISO9001/14001 Certification File No: APP003 CONTENTS REV: 1 ...

Page 4

...

Page 5

...

Page 6

Sample Inspection Record FREEPORT Part Name: HDMI Receptacle SMT type,without flange Part No. : 51U019S-325N-AR-B Drawing NO. Specification Position B5 4.40 4.80 AVG= B5 5.76 6.16 5.92 AVG= C2 13.85 14.15 AVG= D3 4.40 4.70 AVG= E2 8.80 9.20 AVG= ...

Page 7

Sample Inspection Record FREEPORT Part Name: HDMI Receptacle SMT type,without flange Part No. : 51U019S-325N-AR-B Drawing NO. Specification Position 0.50(PITCH (DIMENSION ...

Page 8

PRODUCT SPECIFICATION 1. Scope 1.1 Content This specification is designated the Performance, Tests and quality requirements for High-Definition Multimedia Interface(HDMI) Connector. 1.2 Design and Construction Product shall be conformed the Design, Construction and Physical dimensions shown as product drawing. 2. ...

Page 9

Test description TEST DESCRIPTION ITEM Visual Inspection Refer RS-364-18 Low Level Contact Resistance (Contact): Refer to: 1. RS-364-23 2 Contact Resistance(shell) Refer to: 1.RS-364-06A-83 Insulation Resistance Refer to: 1. RS-364- MIL-STD-202F 3. MIL-STD-1344A 3001.1 ...

Page 10

TEST DESCRIPTION ITEM Humidity Refer to: 1.RS – 364 – 31 2.MIL – STD – 202F 103B 3.MIL – STD – 1344A 1002.2 7 Insertion Force & Withdrawal Force Refer to: 8 1.RS-364-37 2.MIL-STD-1344A- 2013.1 Salt Spray Refer to: 1.RS ...

Page 11

Test sequences: Test of Examination Visual Inspection Low Level Contact Resistance Insulation Resistance Dielectric Withstanding Voltage Solderability Durability Humidity Mating & Unmating Force Salt Spray Temperature Life REV. ECN. NO. APPO Test Sequence 1,7 ...

Page 12

FREEPORT ...

Page 13

FREEPORT Applicant Sample Model/Type Sample of Receiving Date Testing Period Test Requested To determination the Reliability of the submitted sample. Test Method As Product Specification,with reference to MIL-STD-1344A/202F. Results 1.Electrical Test 2.Mechanical Test 3.Environmental Test Please refer to next page ...

Page 14

FREEPOR Test Result TABLE I : Test Sequence/Group & Result ...

Page 15

FREEPORT Product Name Moldel/Type Instrument Calibration due date Test Item Requirement Result of measurement Note: Test Recording Sheet Client Manufacture Sample Group Test Date Test Environment Sample Q'ty ...

Page 16

FREEPORT Product Name Moldel/Type Instrument Calibration due date Test Item Requirement Result of measurement Note: Test Recording Sheet Client Manufacture Sample Group Test Date Test Environment Sample Q'ty ...

Page 17

FREEPORT Product Name Moldel/Type Instrument Calibration due date Test Item Requirement Result of measurement Note: Test Recording Sheet Client Manufacture Sample Group Test Date Test Environment Sample Q'ty ...

Page 18

FREEPORT Product Name Moldel/Type Instrument Calibration due date Test Item Requirement Result of measurement Note: Test Recording Sheet Client Manufacture Sample Group Test Date Test Environment Sample Q'ty ...

Page 19

FREEPORT Product Name Moldel/Type Instrument Calibration due date Test Item Requirement Result of measurement Note: Test Recording Sheet Client Manufacture Sample Group Test Date Test Environment Sample Q'ty ...

Page 20

...

Page 21

LCP PAGE2 ...

Page 22

...

Page 23

...

Page 24

...

Page 25

TEST REPORT APPLICANT: FREEPORT RESOURCES ENTERPRISES CORP WUSHA 6TH INDUSTRIAL AREA, CHANGAN TOWN, DONGGUAN CITY GUANGDONG PROVINCE ATTN SAMPLE DESCRIPTION: ONE (1) SUBMITTED SAMPLE SAID TO BE LCP BLACK. TESTED COMPONENT: DARK GREY PLASTIC. FACTORY COUNTRY OF ...

Page 26

TEST REPORT TESTS CONDUCTED (A) TEST RESULT SUMMARY FOR RoHS DIRECTIVE : TESTING ITEM CADMIUM (Cd) CONTENT (mg/kg) LEAD (Pb) CONTENT (mg/kg) MERCURY (Hg) CONTENT (mg/kg) 6+ CHROMIUM (VI) (Cr NON-METAL) POLYBROMINATED BIPHENYLS (PBBs) (mg/kg) MONOBROMOBIPHENYL (MonoBB) DIBROMOBIPHENYL (DiBB) TRIBROMOBIPHENYL ...

Page 27

TEST REPORT TESTS CONDUCTED (B) RoHS REQUIREMENT : RESTRICTED SUBSTANCES CADMIUM (Cd) LEAD (Pb) MERCURY (Hg) 6+ CHROMIUM (VI) (Cr POLYBROMINATED BIPHENYLS (PBBs) POLYBROMINATED DIPHENYL EHTERS (PBDEs) THE ABOVE LIMITS WERE QUOTED FROM 2002/95/EC AND AMENDMENT 2005/618/EC FOR HOMOGENEOUS MATERIAL. ...

Page 28

TEST REPORT TESTS CONDUCTED (D) MEASUREMENT FLOWCHART: 1. TEST FOR Cd/Pb CONTENTS: PUT WEIGHED SAMPLE INTO A SUITABLE VESSEL ANALYZE BY ICP- OES. 2. TEST FOR Hg CONTENT: PUT WEIGHED SAMPLE INTO A MICROWAVE DIGESTION VESSEL ANALYZE BY ICP- OES. ...

Page 29

TEST REPORT TESTS CONDUCTED 3. TEST FOR CHROMIUM (VI) (Cr WEIGH SAMPLE IN AN ERLENMEYER FLASK ADJUST THE pH OF THE SOLUTION TO 2.0±0.5 AND MAKE UP WITH DEIONIZED WATER ANALYZE THE MIXTURE BY USING UV- VIS SPECTROPHOTOMETER WITH WAVELENGTH ...

Page 30

TEST REPORT TESTS CONDUCTED ********************************************************************** Intertek Testing Services Shenzhen Ltd.-TFH Division 7/F., ShekouTechnology Main Building, Industrial 7th Road,Shekou,Shenzhen, China Tel: (86-755) 2602 0111 Fax: (86-755) 2683 7118/9 Postcode: 518067 Attention is drawn to the terms and conditions printed overleaf. 3 ...

Page 31

TEST REPORT APPLICANT: FREEPORT RESOURCES ENTERPRISES CORP WUSHA 6TH INDUSTRIAL AREA, CHANGAN TOWN, DONGGUAN CITY GUANGDONG PROVINCE ATTN SAMPLE DESCRIPTION: ONE (1) SUBMITTED SAMPLE SAID TO BE SILVER/GOLD COLOR METAL (TERMINAL). FACTORY COUNTRY OF ORIGIN *********************************************************************** TESTS ...

Page 32

TEST REPORT TESTS CONDUCTED (A) TEST RESULT SUMMARY FOR RoHS DIRECTIVE : TESTING ITEM CADMIUM (Cd) CONTENT (mg/kg) LEAD (Pb) CONTENT (mg/kg) MERCURY (Hg) CONTENT (mg/kg) 6+ CHROMIUM (VI)(Cr ) RESULT (BY BOILING WATER EXTRACTION ON METAL) (mg/kg WITH 2 ...

Page 33

TEST REPORT TESTS CONDUCTED (C) TEST METHOD : TESTING ITEM WITH REFERENCE TO IEC 62321 -111/54/CDV, CADMIUM (Cd) BY ACID DIGESTION AND DETERMINED BY ICP- CONTENT OES WITH REFERENCE TO IEC 62321 -111/54/CDV, LEAD (Pb) BY ACID DIGESTION AND DETERMINED ...

Page 34

TEST REPORT TESTS CONDUCTED (D) MEASUREMENT FLOWCHART: 1. TEST FOR Cd/Pb CONTENTS PUT WEIGHED SAMPLE INTO A SUITABLE VESSEL ANALYZE BY ICP- OES. 2. TEST FOR Hg CONTENT PUT WEIGHED SAMPLE INTO A MICROWAVE DIGESTION VESSEL ANALYZE BY ICP- OES. ...

Page 35

TEST REPORT TESTS CONDUCTED 3. TEST FOR CHROMIUM (VI) (Cr MEASURE SURFACE AREA OF TEST SAMPLE ANALYZE THE MIXTURE BY USING UV-VIS SPECTROPHOTOMETER WITH WAVELENGTH SET AT 540 nm *********************************************************************** Intertek Testing Services Shenzhen Ltd.-TFH Division 7/F., ShekouTechnology Main Building, ...

Page 36

TEST REPORT APPLICANT: FREEPORT RESOURCES ENTERPRISES CORP WUSHA 6TH INDUSTRIAL AREA, CHANGAN TOWN, DONGGUAN CITY GUANGDONG PROVINCE ATTN SAMPLE DESCRIPTION: ONE (1) SUBMITTED SAMPLE SAID TO BE SILVER COLOR METAL (SHELL). FACTORY COUNTRY OF ORIGIN *********************************************************************** TESTS ...

Page 37

TEST REPORT TESTS CONDUCTED (A) TEST RESULT SUMMARY FOR RoHS DIRECTIVE : TESTING ITEM CADMIUM (Cd) CONTENT (mg/kg) LEAD (Pb) CONTENT (mg/kg) MERCURY (Hg) CONTENT (mg/kg) 6+ CHROMIUM (VI)(Cr ) RESULT (BY BOILING WATER EXTRACTION ON METAL) (mg/kg WITH 2 ...

Page 38

TEST REPORT TESTS CONDUCTED (C) TEST METHOD : TESTING ITEM WITH REFERENCE TO IEC 62321 -111/54/CDV, CADMIUM (Cd) BY ACID DIGESTION AND DETERMINED BY ICP- CONTENT OES WITH REFERENCE TO IEC 62321 -111/54/CDV, LEAD (Pb) BY ACID DIGESTION AND DETERMINED ...

Page 39

TEST REPORT TESTS CONDUCTED (D) MEASUREMENT FLOWCHART: 1. TEST FOR Cd/Pb CONTENTS PUT WEIGHED SAMPLE INTO A SUITABLE VESSEL ANALYZE BY ICP- OES. 2. TEST FOR Hg CONTENT PUT WEIGHED SAMPLE INTO A MICROWAVE DIGESTION VESSEL ANALYZE BY ICP- OES. ...

Page 40

TEST REPORT TESTS CONDUCTED 3. TEST FOR CHROMIUM (VI) (Cr MEASURE SURFACE AREA OF TEST SAMPLE ANALYZE THE MIXTURE BY USING UV-VIS SPECTROPHOTOMETER WITH WAVELENGTH SET AT 540 nm *********************************************************************** Intertek Testing Services Shenzhen Ltd.-TFH Division 7/F., ShekouTechnology Main Building, ...

Page 41

...

Related keywords