SNLF-S-C25-25S-BN ITT Cannon, SNLF-S-C25-25S-BN Datasheet

CONNECTOR, FEMALE, FREE, BROWN

SNLF-S-C25-25S-BN

Manufacturer Part Number
SNLF-S-C25-25S-BN
Description
CONNECTOR, FEMALE, FREE, BROWN
Manufacturer
ITT Cannon
Series
Snaplockr
Datasheet

Specifications of SNLF-S-C25-25S-BN

Gender
Receptacle
Voltage Rating
415VAC
Current Rating
250A
Connector Mounting
Cable Mount
Contact Termination
Crimp
Svhc
No SVHC
Connector Type
Standard Power Entry
Cable Diameter Max
14mm
Colour
Brown
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Related parts for SNLF-S-C25-25S-BN

SNLF-S-C25-25S-BN Summary of contents

Page 1

...

Page 2

POWERLOCK Applications The Veam POWERLOCK connector series for field installable power distribution systems offers the ultimate in safety and reliability under the most severe operating conditions. POWERLOCK is available in four standard formats which allow complete hook up through the ...

Page 3

Fuse carriers with integrated Powerlock connectors provide a safe and efficient connection to a power distribution board www.ittcannon.com/powerlock POWERLOCK Applications . Insulated G-Style clamps for direct connection to a live low voltage busbar offer a wide variety of ...

Page 4

In addition to our POWERLOCK series, we also offer these connectivity solutions: Harsh environments APD In-line and bulkhead connectors resistant to harsh environmental conditions (contaminants, vibration and shock). Audio Entertainment & Lighting CA-Bayonet Signal and power connectors with exceptional sealing ...

Page 5

Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Page 6

Product Overview Number of Contacts Max. Current Rating AWG Contact Termination Contact Type Contact Retention Systems Contact Extraction System Mating Method Operating Voltage Signal / Power Layouts Operating Temperature Environmental Resistance Sealing Protection against electric shock Mating Cycle Shell Material ...

Page 7

Example: NLDFT-1-BK-L-C240-M40A Harmonised Colour Coding On March 31st 2004, the IEE published Amendment No BS7671:2001 (the IEE Wiring Regulations). This amendment specifies new cable core colours for electrical installations in the UK. These colours harmonise Europe to one ...

Page 8

Line Source Line Source 400A, Earth Green There are two Line Source connectors for cable attachment, normally referred 400A and 660A version. Both are supplied with a male contact incorporating a rigid IP2X finger proof nose, a ...

Page 9

Line Drain 400A, Earth Green There are two Line Drain connectors for cable attachment, normally referred 400A and 660A version. Both are supplied with a female contact incorporating a rigid IP2X spring loaded finger proof nose, an ...

Page 10

Panel Source & Panel Drain Panel Source 400A, Earth Green There are four connectors for panel mounting, a Panel Source and Panel Drain in both 400A and 660A version. The Panel Source connectors are supplied with a male contact incorporating ...

Page 11

Powerlock Finger Test and Secondary Lock Assembly Instructions Secondary Locking Release Key The Secondary Locking Release Key is used to push the secondary locking pin back, which then enables the connectors to be rotated and uncoupled. The visuals below show ...

Page 12

Technical Data Maximum current rating: Maximum rated voltage to earth: Minimum flashover: Operating temperature range: Insulation resistance: Ingress protection (mated): Protection against electrical shock: Flammability: PANEL CUT-OUT DIMENSIONS CONNECTOR DIMENSIONS Panel Drain 68.30 59.30 31.00 24.60 11.25 12.70 Panel Source ...

Page 13

Special Products DIN Fuse Carrier Adaptor This fuse carrier adaptor was developed to provide a safe and efficient Powerlock connection to DIN fuse carrier racks which are mounted on most of the European power distribution boards. There are Full ...

Page 14

Powerlock Insulator Kits NOTE: Insulator kits are used to convert old UK colour coded powerlock connectors to new harmonised colours as explained on page 7. LINE DRAIN Line Drain insulator kit consists of a marked and labelled insulator, O-ring on ...

Page 15

PANEL SOURCE Panel Source insulator kit consists of a marked and labelled insulator and a nylon pin. Description Insulator Kit NPS-1-BN (brown) Insulator Kit NPS-2-BK (black) Insulator Kit NPS-3-GY (grey) Insulator Kit NPS-N-BL (blue) Insulator Kit NPS-E-GN (green) Panel Drain ...

Page 16

Snaplock Connector Series TECHNICAL DATA Rated voltage: Rated current: Ingress protection: Operating temperature range: Protecting against electric shock: Flammability: The Snaplock connector series is a miniature power cable hook up system offering high current capability while maintaining minimal physical dimensions. ...

Page 17

Example: SNLM-P-C35-25L-BK www.ittcannon.com/powerlock Snaplock Order Code 17 ...

Page 18

Snaplock Connector Series CONNECTOR DIMENSIONS 48.00 27.00 26.00 5.00 PANEL MALE 47.00 27.00 18.00 5.00 PANEL FEMALE PANEL CUT-OUT DIMENSIONS Cutout for Panel Connectors 30.00 4 HOLES ø 5.00mm www.ittcannon.com/powerlock 76.50 CABLE FEMALE 26.00 CABLE MALE OVERALL ASSEMBLED LENGTH 186.00 ...

Page 19

The NRG Sequential mating system comes in a 19” rack format and guarantees the proper sequence of mating and un-mating a set of POWERLOCK connectors. The patented cam operated covers on each of the panel connectors ensure that the correct ...

Page 20

Powerlock NRG Cabinet Assembly The Powerlock Power Distribution Cabinet has been designed and tested to conform to the requirements for CE marking by implementing the requirements of the Low Voltage Directive (LVD) 73/23/EEC which is implemented as the Electrical Equipment ...

Page 21

Completely insulated which allows for direct connection of a generator cable to a live low voltage busbar. • The clamp is fixed to the busbar by means of an insulated box spanner which meets the requirements of IEC 60900 ...

Page 22

Insulated Horizontal Clamp • Completely insulated which allows for direct connection of a generator cable to a live low voltage busbar. • The clamp is fixed to the busbar by means of an insulated box spanner which meets the requirements ...

Page 23

Completely insulated which allows for direct connection of a generator cable to a live low voltage busbar. • The clamp is fixed to the busbar by means of an insulated box spanner which meets the requirements of IEC 60900 ...

Page 24

Insulated Overhead Line Clamp / Generator Connector This device allows for direct connection of a generator unit to Low Voltage overhead line systems. The unit consists of an insulated Line Clamp, 3 metres of 50mm generator input cable. The methods ...

Page 25

Insulated Underground Cable Generator Connector This compact unit incorporates a POWERLOCK generator input connection point with a rear termination area to accept solid alloy cable cores. This enables a temporary mobile generator to be connected to an underground cable when ...

Page 26

JW4ST Fuse Carrier with Integral Generator Input Connector JW4ST (35/8 inch pitch) fuse carrier was developed to provide a safe and efficient means of connecting a mobile generator supply cable to fully shrouded or non-shrouded distribution boards. The unit complies ...

Page 27

The Multi-Converter enables any user to easily convert lugged cable to POWERLOCK within minutes ensuring all safety and security of basic POWERLOCK connector series. A POWERLOCK connection point is incorporated within the unit to allow for direct connection of the ...

Page 28

Fully Insulated Cable Support The insulated cable support will handle 25mm accomodate substation LV boards and / or customer switchgear. The support is easily transportable due to the removable base fully insulated and complements our range of mobile ...

Page 29

Different variations available, please contact Customer Service 3 Phase and Neutral G-Clamp Kit ITT Part # 078214-9900 Consists of: LVS200-1-BN LVS200-2-BK LVS200-3-GY LVS200-N-BL LVL200H Watertight Protective Case 3 Phase and Neutral Underground Connector Kit ITT Part # 078214-9903 Consists of: ...

Page 30

Product Safety Information THIS NOTE MUST BE READ IN CONJUNC- TION WITH THE PRODUCT SHEET/CATALOG. FAILURE TO OBSERVE THE ADVICE IN THIS INFORMATION SHEET AND THE OPERATING CONDI- TIONS SPECIFIED IN THE PRODUCT DATA SHEET/ CATALOG COULD RESULT IN HAZARDOUS ...

Page 31

...

Related keywords