DR1030-470-R COILTRONICS, DR1030-470-R Datasheet

POWER INDUCTOR, 47UH

DR1030-470-R

Manufacturer Part Number
DR1030-470-R
Description
POWER INDUCTOR, 47UH
Manufacturer
COILTRONICS
Datasheet

Specifications of DR1030-470-R

Inductance Tolerance
± 30%
Dc Resistance Max
0.2ohm
Dc Current Rating
1.3Arms
Core Material
Ferrite
No. Of Pins
2
Inductor Type
Power
External Height
3mm
Terminal Type
SMD
Inductance
47µH
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DR1030-470-R
Manufacturer:
EATON/COOPER
Quantity:
20 000
Description
• 125°C maximum total temperature operation
• Low profile surface mount inductors
• 10.3mm x 10.5mm x 3.0mm shielded drum core
• Ferrite core material
• Inductance range from 1.1µH to 150µH
• Current range from 9.5 Amps to 0.68 Amps
• Frequency range up to 1MHz
Applications
• Computer, DVD players, and portable power devices
• Notebook power, LCD panels
• DC-DC converters
• Input/output filter, Buck/Boost regulators
Environmental Data
• Storage temperature range: -40°C to +125°C
• Operating temperature range: -40°C to +125°C
• Solder reflow temperature: +260°C max. for 10 seconds
(1) Open Circuit Inductance Test Parameters: 100kHz, 0.1V, 0.0Adc.
(2) Irms: DC current for an approximate ∆T of 40°C without core loss. Derating is
Part Number
DR1030-1R1-R
DR1030-1R8-R
DR1030-2R8-R
DR1030-3R9-R
DR1030-5R2-R
DR1030-6R8-R
DR1030-8R2-R
DR1030-100-R
DR1030-150-R
DR1030-220-R
DR1030-330-R
DR1030-470-R
DR1030-680-R
DR1030-820-R
DR1030-101-R
DR1030-121-R
DR1030-151-R
(range is application specific)
maximum
necessary for AC currents. PCB layout, trace thickness and width, air-flow, and
proximity of other heat generating components will affect the temperature rise. It
is recommended that the temperature of the part not exceed 125°C under worst
case operating conditions verified in the end application.
Inductance
Rated
(µH)
100
120
150
1.1
1.8
2.8
3.9
5.2
6.8
8.2
10
15
22
33
47
68
82
µH ± 30%
OCL (1)
119.3
155.3
10.4
14.8
22.8
32.4
47.9
66.6
82.4
100
1.1
1.9
2.8
4.0
5.2
6.8
8.4
Amperes
Irms (2)
0.86
0.68
7.0
5.9
5.1
4.3
3.7
3.5
3.3
2.8
2.3
1.8
1.6
1.3
1.1
1.0
0.8
2002/95/EC
RoHS
(3) Isat Amperes peak for approximately 35% rolloff max. (@25°C)
(4) K-factor: Used to determine B p-p for core loss (see graph).
(5) Part Number definition: DR1030-xxx-R
Packaging
• Supplied in tape and reel packaging,
Amperes
Isat (3)
1000 parts per reel
B p-p = K*L*∆I, B p-p(mT), K: (K factor from table), L: (Inductance in uH),
∆I (Peak to peak ripple current in Amps).
DR1030 = Product code and size, xxx = Inductance value in µH, R = decimal
point. If no R is present third character = # of zeros. -R suffix = RoHS compliant
9.50
7.41
6.08
5.13
4.75
3.90
3.54
3.18
2.66
2.19
1.81
1.52
1.24
1.14
1.05
0.95
0.86
mΩ@20°C
(Typical)
113.6
166.6
253.1
332.4
375.0
523.4
590.0
DCR
12.1
16.4
22.9
24.9
28.4
40.2
57.3
95.5
Low Profile Power Inductors
6.5
9.1
(Maximum)
mΩ@20°C
114.6
136.3
200.0
303.7
382.3
450.0
602.0
DCR
11.0
14.5
20.0
27.5
30.0
34.1
48.0
68.8
700
7.9
DR1030 Series
K-factor
9.0
8.0
7.0
6.0
4.5
3.4
2.9
2.6
2.4
1.9
1.4
(4)
22
17
14
12
10
4

Related parts for DR1030-470-R

DR1030-470-R Summary of contents

Page 1

... DR1030-5R2-R 5.2 DR1030-6R8-R 6.8 DR1030-8R2-R 8.2 DR1030-100-R 10 DR1030-150-R 15 DR1030-220-R 22 DR1030-330-R 33 DR1030-470-R 47 DR1030-680-R 68 DR1030-820-R 82 DR1030-101-R 100 DR1030-121-R 120 DR1030-151-R 150 (1) Open Circuit Inductance Test Parameters: 100kHz, 0.1V, 0.0Adc. (2) Irms: DC current for an approximate ∆T of 40°C without core loss. Derating is necessary for AC currents. PCB layout, trace thickness and width, air-flow, and proximity of other heat generating components will affect the temperature rise recommended that the temperature of the part not exceed 125° ...

Page 2

... wwlly 16.0 Ao User direction of feed 1MHz 1MHz 10 10 Bp-p (mT) Bp-p (mT) DR1030 Series Low Profile Power Inductors SCHEMA TIC RECOMMENDED PCB LAYOUT 3.3 1 1.6 7.3 2 1.5 dia A min 1.75 12.0 24.0 +/-0.3 0.5 rad typ A 500kHz 500kHz ...

Page 3

... Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Low Profile Power Inductors 0.40 0.60 0.80 Total Loss (W) OCL vs. I SAT 40.0% 60.0% 80. SAT DR1030 Series 1.00 1.20 100.0% 120.0% ...

Related keywords