E3C-LS3R-01 Omron, E3C-LS3R-01 Datasheet

Photoelectric Sensors - Industrial PHOTO ELECTRIC

E3C-LS3R-01

Manufacturer Part Number
E3C-LS3R-01
Description
Photoelectric Sensors - Industrial PHOTO ELECTRIC
Manufacturer
Omron
Series
E3Cr
Datasheet

Specifications of E3C-LS3R-01

Sensing Distance
1.181" (30mm)
Sensing Method
Reflective, Convergent
Sensing Object
White Paper
Output Configuration
-
Sensing Light
Red
Mounting Type
Bracket Mount
Current - Supply
-
Voltage - Supply
-
Package / Case
Module, Pre-Wired
Features
Compact Model
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Thin, Compact Head Saves Space
and Mounts Closely. Built-in
Interference Protection Provided.
• Input indicator on the Sensor Unit simplifies settings.
Ordering Information
Sensors
Sensor Units
* Through-beam Sensors are normally sold in sets that include both the Emitter and Receiver.
Orders for individual Emitters and Receivers are accepted. (Modifications are required for some models. Ask your OMRON representative for details.)
Compact Head Amplifier-separated Photoelectric Sensor
E3C
(Emitter + Receiver)
Convergent-reflective
Sensing method
Diffuse-reflective
Be sure to read Safety Precautions on
page 11.
Through-beam
[Refer to Dimensions on page 12.]
*
Application
Small type
Small type
Small type
Side-view
Side-view
Slim type
Slim type
12.5
19.5
3
12
36
12
2.8
10
5.8
2.8
8
18
25
10
18
18
Appearance
15
7.85
8
16
12.4
3
13
21
26
15
7
36
10
11
11
8
15
Sensing distance
30±3 mm
50 mm
100 mm
100 mm
100 mm
200 mm
300 mm
500 mm
1 m
2 m
E3C-S10 2M
Emitter
Receiver E3C-S10D 2M
E3C-S50 2M
Emitter
Receiver E3C-S50D 2M
E3C-1 2M
Emitter
Receiver E3C-1D 2M
E3C-2 2M
Emitter
Receiver E3C-2D 2M
E3C-S20W 2M
Emitter
Receiver E3C-S20DW 2M
E3C-S30W 2M
Emitter
Receiver E3C-S30DW 2M
E3C-S30T 2M
Emitter
Receiver E3C-S30DT 2M
E3C-DS10 2M
E3C-DS5W 2M
E3C-DS10T 2M
E3C-LS3R 2M
Red light
E3C-S10L 2M
E3C-S50L 2M
E3C-1L 2M
E3C-2L 2M
E3C-S20LW 2M
E3C-S30LW 2M
E3C-S30LT 2M
Model
CSM_E3C_DS_E_7_1
Infrared light
1

Related parts for E3C-LS3R-01

E3C-LS3R-01 Summary of contents

Page 1

... CSM_E3C_DS_E_7_1 Red light Infrared light Model E3C-S10 2M Emitter E3C-S10L 2M Receiver E3C-S10D 2M E3C-S50 2M Emitter E3C-S50L 2M 500 mm Receiver E3C-S50D 2M E3C-1 2M Emitter E3C- Receiver E3C-1D 2M E3C-2 2M Emitter E3C- Receiver E3C-2D 2M E3C-S20W 2M Emitter E3C-S20LW 2M Receiver E3C-S20DW 2M E3C-S30W 2M Emitter E3C-S30LW 2M Receiver E3C-S30DW 2M 300 mm E3C-S30T 2M Emitter E3C-S30LT 2M ...

Page 2

... Provided with the E3C-1. Provided with the E3C-2. 2 Can be used with the E3C-DS10 Can be used with the E3C-S10 Can be used with the E3C-S50. Quantity Remarks 1 Provided with the E3C-A/C. 1 Can be used with the E3C-GE4. 1 Can be used with the E3C-GE4. Model --- ...

Page 3

... Infrared LED (950 nm) 2 for 3 times each and Z directions IEC 60529 IP64 (Limited to indoor use) Instruction manual E3C E3C-1 E3C Opaque, 4-mm Opaque, 8-mm dia. min. dia. min. Emitter/Receiv- Emitter/Receiv- er 20° each er 15° ...

Page 4

... Approx --- Iron Mounting Bracket, Adjustment screwdriver, Caution label, Instruction manual E3C E3C-JC4P E3C-GE4 Load power supply voltage: 24 VDC max., load current max., voltage output type, output current (residual voltage: 0.7 V max.) Light-ON/Dark-ON cable con- nection selectable --- --- ...

Page 5

... X (mm) −100 −150 −200 Through-beam E3C-S30T/-S30W 200 Y 150 X 100 50 0 600 200 400 800 Sensing −50 distance X (mm) −100 −150 −200 Diffuse-reflective E3C-DS10 (Example OFF 30 Y Moving direction of object Optical 20 axis 120 200 160 −10 Sensing distance −20 X (mm) − ...

Page 6

... Diffuse-reflective E3C-DS10 (Example Moving direction of object OFF 30 Y Optical 20 axis 120 200 160 −10 Sensing distance −20 X (mm) −30 −40 Excess Gain vs. Set Distance E3C-S20W 100 Operating Level 1 0.7 0.5 0.3 0.1 0 100 200 300 400 500 Set distance (mm) E3C-DS5W 100 ...

Page 7

... For t in the timing chart, refer to Part Names/Selection Method on page 9. Operation * selector t t LIGHT ON Synchronous 9 inputs * DARK E3C-C only * 2. E3C-A/-C have SPDT contact output. (About terminal number, please refer to the connection section.) L-ON Light (LIGHT ON) indicator (red D-ON (DARK ON Switched with wiring. − ...

Page 8

... Receiver side (white) − (Note) and 50 mm max. on the Gate input Emitter side (red The E3C-A does not have a gate input function when the gate input 2-9 terminals are connected, H when they are 7 8 disconnected. 100 to 240 VAC Emitter/receiver Note: 1 ...

Page 9

... Output t Relay Solid state T "a" "H" "b" "L" "a" "H" "b" "L" "a" "H" "b" "L" T "a" "H" "b" "L" "a" "H" "b" "L" "a" "H" "b" "L" E3C (Output transistor) (ON) (OFF) (ON) (OFF) (ON) (OFF) (ON) (OFF) (ON) (OFF) (ON) (OFF) 9 ...

Page 10

... H disconnected * power supply Timing chart Incident light No incident light − − E3C Settings --- DARK turns the output "H". LIGHT turns the output "H". The response time is set to 2 ms. The response time is set No-contact (Output output transistor) "H" (OFF) "L" ...

Page 11

... Emitter (Shield) Red Connection Socket The standard socket is the PF113A for the E3C-A and -C, and the PYF08A, PYF08M or PY08 for the E3C-GE4. Avoid using any other sockets since they may not satisfy the characteristics. (There will be no problem when the STABILITY indicator turns ON) Sensor Units ● ...

Page 12

... Dimensions Sensors Sensor Units E3C-S10 Emitter: E3C-S10L Receiver: E3C-S10D E3C-S50 Emitter: E3C-S50L Receiver: E3C-S50D E3C 3.5 Emitter: E3C-1L Lens 4 dia. Receiver: E3C-1D (A)* E3C Lens 8 dia. (A)* Emitter: E3C-2L * Mounting Bracket can be attached to side A. Receiver: E3C-2D Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. ...

Page 13

... E3C-S20LW Receiver: E3C-S20DW E3C-S30W Emitter: E3C-S30LW Receiver: E3C-S30DW E3C-S30T 1.93-dia. shielded robotics cable with 1 conductor (Conductor cross section: 0.15 mm Standard length Emitter: E3C-S30LT Receiver: E3C-S30DT E3C-DS10 Receiver 2 2 dia. (receiver) 2,000 18 4.5 (white) 4 (6) 12.5 1.75-dia. shielded cable 2.5 with 1 conductor ± ...

Page 14

... Standard length 4 Emitter Receiver Lens 13 Optical axis ±1 R3 position 30 2.4-dia. shielded cable with 2 conductors (Conductor cross section: 0.3 mm Standard length Receiver 4 ±0.2 7 19.5 6 3.8 dia. 2.3 dia. 2.5 1.4 Emitter 2.8 4.6 R1.2 6.6 2 E3C 14 ...

Page 15

... R1.6 3 35.5 *After adjusting the sensitivity, attach the caution label at the location indicated by above to prevent malfunction. Light indicator (red) 20.7 35.5 5.4 E3C PF113A 51.5 73.5 24.5 4 109 Insulator diameter: 1.2mm), Connector Use the PYF08A front connection socket or PY08 rear connection socket. ...

Page 16

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords