B72232B131K1 EPCOS Inc, B72232B131K1 Datasheet - Page 8

no-image

B72232B131K1

Manufacturer Part Number
B72232B131K1
Description
Varistor, Circuit Protection; 130Vrms/170VDC; 340V; 25000A; Metal Oxide; 4400pF; Screw
Manufacturer
EPCOS Inc
Type
MOVr
Datasheet

Specifications of B72232B131K1

Technology
Metal Oxide
Capacitance Value
4400pF
Clamping Current
200A
Clamping Voltage
340V
Lead Style
Screw
Ac Voltage Rating (max)
130VAC
Dc Voltage Rating (max)
170VDC
Operating Temp Range
-40C to 85C
Mounting
Bolt-Down
Surge Current (max)
25000A
Lead Spacing
24mm
Product Length (mm)
60mm
Product Depth (mm)
14mm
Product Height (mm)
55mm
Energy
210Joule
Varistor Voltage
205V
Brand/series
E Series
Capacitance
4400 pF
Current, Peak
25000 A
Dimensions
60 mm W x 55 mm H x 14 mm T
Electric Strength
≥2.5 kV (RMS) (Min.)
Energy Rating
210 Joules
Mounting Style
Leaded
Package
Screw
Power Rating
1.2 W
Resistance, Insulation
≥10 Megohms (Min.)
Temperature, Operating, Maximum
85 °C
Temperature, Operating, Minimum
-40 °C
Terminal Type
Screw
Voltage, Ac
130 VAC
Voltage, Clamping
340 V
Voltage, Dc
170 VDC
Voltage, Operating
130 Vrms⁄170 VDC
Voltage, Varistor
205
Lead Free Status / RoHS Status
Compliant
Reliability data
Test
Varistor voltage
Clamping voltage
Max. DC operating voltage The maximum allowable DC operating
Surge current derating,
8/20 µs
Fast temperature cycling
Damp heat, steady state
Note:
UCT = Upper category temperature
LCT = Lower category temperature
Please read Cautions and warnings and
Important notes at the end of this document.
Block varistors
HighE series
Test methods/conditions
The voltage between two terminals with
the specified measuring current applied
is called V
The maximum voltage between two
terminals with the specified standard
impulse current (8/20 µs) applied.
voltage V
applied for 1000 ±48 h.
The leakage current I
is recorded.
Then the specimen shall be stored at
room temperature and normal humidity
for 1 to 2 h.
Thereafter, the change of V
measured.
10 surge currents (8/20 µs), unipolar,
interval ≥60 s, amplitude correspond-
ing to derating curve for 10 impulses
at 20 µs
IEC 60068-2-14, test Na, LCT/UCT,
dwell time 120 min, 5 cycles
IEC 60068-2-78
The specimen shall be subjected to
40 ±2 °C, 90 to 95% r. H. for 56 ±2 days
with 10% of the maximum continuous
DC operating voltage V
Then stored at room temperature and
normal humidity for 1 to 2 h.
Thereafter, the change of V
measured.
DC
v
(1 mA
at UCT +5/–0 °C is
DC
8
@ 0.2 … 2 s).
leak
DC
11/07
(t) during test
.
v
v
shall be
shall be
Requirement
To meet the specified value.
To meet the specified value.
I
|
|
(measured in direction
of surge current)
No visible damage
|
No visible damage
|
leak
∆V/V (1 mA)
∆V/V (1 mA)
∆V/V (1 mA)
∆V/V (1 mA)
(t = 1000 h) ≤ I
|
|
|
|
≤10%
≤10%
≤10%
≤10%
leak
(t = 0 h)

Related parts for B72232B131K1