G3PA-420B-VD-2DC12-24 Omron, G3PA-420B-VD-2DC12-24 Datasheet

no-image

G3PA-420B-VD-2DC12-24

Manufacturer Part Number
G3PA-420B-VD-2DC12-24
Description
Solid State Relays 12-24 IN 180-528 OUT
Manufacturer
Omron
Datasheet

Specifications of G3PA-420B-VD-2DC12-24

Load Voltage Rating
528 V
Relay Type
Solid State
Termination Style
Crimp
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Extremely Thin Relays Integrated with Heat
Sinks
• Downsizing achieved through optimum design of heat sink.
• Mounting possible via screws or via DIN track.
• Close mounting possible for linking terminals. (Except for G3PA-
• Applicable with 3-phase loads.
• Replaceable power element cartridges.
• Comply with VDE 0160 (finger protection), with a dielectric
• Certified by UL, CSA, and VDE (reinforced insulation).
Model Number Structure
■ Model Number Legend
1. Basic Model Name
2. Rated Load Power Supply Voltage
3. Rated Load Current
4. Terminal Type
5. Zero Cross Function
6. Certification
7. Special Specifications
G3PA-@@@@-@-@
260B-VD and G3PA-450B-VD-2.)
strength of 4,000 V between input and load.
Solid State Relays
G3PA
G3PA: Solid State Relay
2:
4:
10:
20:
30:
40:
50:
60:
B:
Blank: Equipped with zero cross function
L:
VD:
Blank: Standard models
2:
1
Refer to Safety Precautions for All Solid State
Relays.
200 VAC
400 VAC
10 A
20 A
30 A
40 A
50 A
60 A
Screw terminals
Not equipped with zero cross function
Certified by UL, CSA, and VDE
480-V models
2 3 4 5
6
7
CSM_G3PA_DS_E_3_1
1

Related parts for G3PA-420B-VD-2DC12-24

G3PA-420B-VD-2DC12-24 Summary of contents

Page 1

... Extremely Thin Relays Integrated with Heat Sinks • Downsizing achieved through optimum design of heat sink. • Mounting possible via screws or via DIN track. • Close mounting possible for linking terminals. (Except for G3PA- 260B-VD and G3PA-450B-VD-2.) • Applicable with 3-phase loads. • Replaceable power element cartridges. ...

Page 2

... VDE certification G3PA-210B-VD DC5-24 Yes G3PA-210BL-VD DC5-24 G3PA-210B-VD AC24 G3PA-220B-VD DC5-24 G3PA-220BL-VD DC5-24 G3PA-220B-VD AC24 G3PA-240B-VD DC5-24 G3PA-240BL-VD DC5-24 G3PA-240B-VD AC24 G3PA-260B-VD DC5-24 G3PA-260BL-VD DC5-24 G3PA-260B-VD AC24 G3PA-420B-VD DC12-24 G3PA-430B-VD DC12-24 G3PA-420B-VD-2 DC12-24 G3PA-430B-VD-2 DC12-24 G3PA-450B-VD-2 DC12-24 Applicable SSR G3PA-210B-VD, G3PA-210BL-VD ...

Page 3

... G3PA-430B-VD-2 G3PA-450B-VD-2 Output Model Rated load voltage G3PA-210B(L)- 240 VAC (50/60 Hz 264 VAC (50/60 Hz) 0 40°C G3PA-220B(L)-VD G3PA-240B(L)-VD G3PA-260B(L)-VD G3PA-420B-VD 180 to 400 VAC (50/60 Hz) 150 to 440 VAC (50/60 Hz) 0 30°C G3PA-430B-VD G3PA-420B-VD-2 200 to 480 VAC (50/60 Hz) 180 to 528 VAC (50/60 Hz) 0 30°C ...

Page 4

... CSA C22.2 CSA C22.2 (No.14), (No.14), EN60947-4-3 EN60947-4-3 File No. File No. 6642ÜG 133127ÜG Approx. Approx. Approx. 900 g 290 g 290 g G3PA G3PA- G3PA- G3PA- 420B-VD-2 430B-VD 430B-VD-2 450B-VD max max. (at 480 VAC) (at 400 VAC 1,800 A s 1,800 A UL508, UL508, CSA C22.2 CSA C22 ...

Page 5

... The G3PA can be broadly divided into two series: Previous models and models with model numbers that end with "-VD." The Cartridge shown at the right cannot be mounted to models in the G3PA-@@@B-(-US) Series. ...

Page 6

... Apply silicone grease (provided with the G32A-A) to the entire surface of the heat sink. G32A-A40(L)-VD/G32A-A60(L)-VD/G32A-A430-VD(-2)/G32A-A450-VD-2 The G32A Power Device Cartridge is mounted and secured with screws to the G3PA Unit. No special tool is required to remove the Cartridge. Extraction Follow the procedures below to dismount the G32A-A Power Device Cartridge from the G3PA ...

Page 7

... Insert the cartridge into the opening of the G3PA so that side A and side B are even. ■ Linking Terminal Connection • Connecting with linking terminal for G3PA-210B(L)-VD, -220B(L)- VD, -240B(L)-VD and G3PA-420B-VD(-2), G3PA-430B-VD(-2). SSR1 SSR2 1. When SSRs are close mounted, loosen the M3.5 Sems screw and flip the linking terminal down ...

Page 8

... For close mounting of two or three SSRs, limit the load current to 90% or less. G3PA-420B-VD, G3PA-420B-VD-2 Ambient temperature (°C) G3PA-420B-VD For single mounting, the ambient temperature is 80°C. The rated current For close mounting of two or three SSRs, limit the load current to 80% or less. G3PA-240B(L)-VD Ambient temperature (°C) G3PA-430B-VD, G3PA-430B-VD-2 Ambient temperature (°C) G3PA G3PA-260B(L)- ...

Page 9

... Input voltage (V) Horizontal Mounting Panel Ground G3PA-210B(L)-VD, G3PA-220B(L)-VD G3PA-220B(L)- G3PA-210B(L)- 5.5 5 3.5 Ambient temperature (°C) G3PA-420B-VD, G3PA-430B-VD G3PA-420B -VD-2, G3PA-430B-VD-2 G3PA-430B-VD G3PA-420B-VD Ambient temperature (°C) G3PA-4@0-VD, G3PA-4@-VD 25° Input 4 current 2 Input impedance 1 0.8 0.6 0.4 0.2 0 Input voltage (V) G3PA-240B(L)-VD ...

Page 10

... Close Mounting (Up to Three) Panel Ground DIN track G3PA-210B(L)-VD, G3PA-220B(L)- G3PA-220B- G3PA-210B- 4.5 Ambient temperature (°C) G3PA-420B-VD, G3PA-420B-VD − Ambient temperature (°C) G3PA-450B-VD-2 Ambient temperature (°C) G3PA-240B(L)- Ambient temperature (°C) G3PA-430B-VD, G3PA-430B-VD −30 100 10 30 Ambient temperature (°C) G3PA G3PA-260B(L)- -30 - 100 Ambient temperature (° ...

Page 11

... One Cycle Surge Current: Non-repetitive Note: Keep the inrush current to half the rated value if it occurs repetitively. G3PA-210B(L)-VD Energized time (ms) G3PA-220B(L)-VD, G3PA-420B-VD, G3PA-420B-VD-2 Energized time (ms) G3PA G3PA-240B(L)-VD/260B(L)-VD, G3PA-430B-VD, G3PA-430B-VD-2, G3PA-450B-VD-2 Energized time (ms) 11 ...

Page 12

... With Terminal Cover 4.6 dia. Two, M3.5 4.6 x 5.6 elliptical hole 100 max. With Terminal Cover 4.6 dia. G3PA Mounting Terminal Holes Arrangement/ Internal Connections Two, 4.5 dia holes Mounting Terminal Holes Arrangement/ Internal Connections Two, 4.5 dia holes ...

Page 13

... G3PA-260B(L)-VD With Terminal G3PA-450B-VD-2 Cover 4.6 x 5.6 elliptical hole 100 max. G3PA-420B-VD, G3PA-420B-VD-2 Without Terminal Cover Two, M4 7.6 Linking terminal 38 67 +B1 Linking terminal −B2 8.6 Two, M3.5 2.2 4.5 x 5.6 elliptic hole 8.8 13.2 G3PA-430B-VD, G3PA-430B-VD-2 Without Terminal Cover Two, M5 7.6 ...

Page 14

... Note: Leave a distance min. between SSRs and ducts (especially above the SSR). SSR Input When attaching a heat sink to the G3PA-(VD), in order to facilitate heat dissipation, apply silicone grease or equivalent heat-conductive grease on the heat sink. (Toshiba Silicone, Shinetsu Silicone, etc.) Tighten the mounting screws of the heat sink with a torque of 0.78 to 0.98 N· ...

Page 15

... If there are other instruments that generate heat in the control panel other than SSRs, additional ventilation will be required. Countermeasure (2) G3PA Airflow If the ducts cannot be shortened, place the SSR on a metal base so that it is not surrounded by the ducts. Ventilation outlet G3PA G3PA 0.16 0.31 0.47 0.62 0.93 ...

Page 16

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords