G5PA-1-M-EDC5BYOMZ(PF) Omron, G5PA-1-M-EDC5BYOMZ(PF) Datasheet - Page 2

no-image

G5PA-1-M-EDC5BYOMZ(PF)

Manufacturer Part Number
G5PA-1-M-EDC5BYOMZ(PF)
Description
RELAY PWR SPST-NO 5VDC PCB
Manufacturer
Omron
Series
G5PA-1r
Datasheet

Specifications of G5PA-1-M-EDC5BYOMZ(PF)

Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
10A
Switching Voltage
277VAC, 30VDC - Max
Turn On Voltage (max)
4 VDC
Turn Off Voltage (min)
0.5 VDC
Relay Type
General Purpose
Coil Type
Non Latching
Coil Current
108mA
Coil Voltage
5VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Features
Sealed - Flux Protection
Contact Material
-
Operate Time
15ms
Release Time
5ms
Coil Power
540 mW
Coil Resistance
46 Ohms
Operating Temperature
-40°C ~ 70°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G5PA1MEDC5BYOMZPF

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G5PA-1-M-EDC5BYOMZ(PF)
Manufacturer:
OMRON
Quantity:
6 000
Specifications
■ Coil Ratings
Note: 1. Each rated current or coil resistance value must allow a tolerance of ±10% at a coil temperature of 23°C.
■ Contact Ratings
■ Characteristics
■ Approved Standards
UL (File No. E41515, UL508)
2
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. permissible voltage
Power consumption
Rated load (capacitive load)
Resistive load (reference value)
Max. switching voltage
Max. switching current
Contact resistance (see note 2)
Operate time
Release time
Insulation resistance (see note 3) 1,000 MΩ min. (at 500 VDC)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
G5PA-1
CSA (File No. LR31928, C22.2 No. 14)
2. The operating characteristics are values at a coil temperature of 23°C.
3. The maximum permissible voltage is the maximum voltage that is applicable to the relay coil for an instant.
Model
Special-purpose PCB Relay
5 to 24 VDC (@40° C)
12 VDC
20.8 mA
576 Ω
80% of rated voltage max.
10% of rated voltage min.
150% of rated voltage (at 23° C)
250 mW (other options available)
250 VAC with inrush current of 100 A (0 to peak) and constant current of 3 A (rms)
10 A @ 250 VAC; 5A @ 30 VDC/277 VAC (@40° C)
277 VAC, 30 VDC
10 A (@40° C)
100 mΩ max.
15 ms max.
5 ms max.
4,000 VAC 50/60 Hz for 1 min between coil and contacts
1,000 VAC 50/60 Hz for 1 min between contacts of same polarity
10 kV (1.2 x 50 µs between coil and contacts), 12 kV optional
Destruction:10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction:10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction:1,000 m/s
Malfunction: 200 m/s
Mechanical: 1,000,000 operations min. (at 18,000 operations an hour)
Electrical: 40,000 operations min. with a rated load at a 1,800 operations an hour.
100,000 operations min. with a resistive load (reference value)
Operating: -40°C to 70°C (with no icing)
Operating: 5% to 85%
Approx. 10 g
Coil ratings
G5PA-1
2
2
5 A, 277 VAC
5 A, 30 VDC
10 A, 250 VAC
TV-5 rating
TV-8 rating
Contact ratings
24 VDC
10.4 mA
2,304 Ω
30,000
6,000
30,000 (optional)
100,000
25,000
25,000 (optional)
Number of test operations

Related parts for G5PA-1-M-EDC5BYOMZ(PF)