3100-30T7999CY TE Connectivity, 3100-30T7999CY Datasheet

no-image

3100-30T7999CY

Manufacturer Part Number
3100-30T7999CY
Description
RELAY CONTACTOR 20A 120VAC QC
Manufacturer
TE Connectivity
Series
3100, Products Unlimitedr
Datasheet

Specifications of 3100-30T7999CY

Contact Form
3PST-NO-DM (3 Form X)
Contact Rating (current)
20A
Switching Voltage
600VAC - Max
Turn On Voltage (max)
88 VAC
Turn Off Voltage (min)
20 VAC
Relay Type
Contactor
Coil Type
Non Latching
Coil Voltage
120VAC
Mounting Type
Chassis Mount
Termination Style
Screw Terminal, .250" QC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Coil Current
-
Other names
9-1611015-4
832
Dimensions are shown for
reference purposes only.
Features
• 3-pole contactors.
• Industry-standard mounting plate.
• Optional interlock/auxiliary switches available.
• Manual test button is standard.
• Coil dust cover helps keep dust and dirt away from magnet and coil area.
• Double E magnet system provides optimal performance.
Contact Data @ 25°C
Material: Silver Cadmium Oxide.
Arrangements: 3 Form X (3PST-NO-DM).
Maximum Ratings: See Contact Ratings Table.
Nominal Coil Voltage
Maximum Pickup Volts
Drop-Out Volts Range
Nominal Inrush VA @ 50 Hz
Nominal Inrush VA @ 60 Hz
Nominal Sealed VA @ 50 Hz
Nominal Sealed VA @ 60 Hz
Nominal DC Resistance - Ohms
Coil Data @ 25°C
Voltage: 24 - 480 VAC, 50/60 Hz. See Coil Data Table below.
Insulation Class: UL Class B (130°C).
Duty Cycle: Continuous.
Contact Ratings
Coil Data
Amps
Load
Full
20
25
30
40
Number
Poles
of
3
3
3
3
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Voltage
240/277
240/277
240/277
240/277
Line
480
600
480
600
480
600
480
600
6 -15
6.0
24
18
60
53
5
7
Locked
Amps
Rotor
Issued 3-03 (PDF Rev. 3-04)
120
100
150
125
100
180
150
120
240
200
160
80
20 - 70
Catalog 1308242
120
180
6.0
88
60
53
5
Resistive
Specifications and availability
subject to change.
Model 98 - 3100
Definite Purpose Contactor
3-pole, 20-40 FLA
AC Coil
Environmental Data
Rating
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Temperature Range: Storage and Operating: -40°C – +65°C.
Flammability: UL 94-HB housing.
Mechanical Data
Coil Termination: Dual 0.250” (6.35 mm) quick connects, standard.
Contact Termination:
20, 25, 30 FLA Models
40 FLA Models
Arc Cover: Optional on 20-30 FLA models, standard on 40 FLA models.
Weight: 16 oz. (455 g) approximately
Amps
30
30
30
35
35
35
40
40
40
50
50
50
Type: #10-32 Screw with quad 0.250” (6.35 mm) quick connects.
Wire Size: 16-8 AWG (Stranding must be split for 8 AWG wire.)
Tightening Torque: 25 in.-lbs.
Type: Box Lug with dual 0.250” (6.35 mm) quick connects.
Wire Size: 14-4 Cu/Al AWG
Tightening Torque: 40 in.-lbs.
File E75492
File EN60947-4-1:1991
IEC 947-4-1
208/240
40 - 140
177
720
6.0
60
53
5
A 0.250” quick connect and a #6-32 screw, optional.
Voltage
110/120
200/240
480/600
110/120
200/208
240/277
110/120
200/208
240/277
110/120
200/208
240/277
480
600
480
600
480
600
Maximum Horsepower
65 - 185
277
220
950
6.0
60
53
5
Single
Phase
PRODUCTS UNLIMITED
1.5
7.5
3
2
5
2
5
3
-
-
-
-
-
-
-
-
-
-
series
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
150 - 270
3100
480
384
6.0
65
53
Phase
Three
5
7.5
7.5
7.5
10
15
20
10
10
15
20
10
10
20
25
-
-
-
-

Related parts for 3100-30T7999CY

3100-30T7999CY Summary of contents

Page 1

... Nominal Sealed Nominal DC Resistance - Ohms Dimensions are shown for 832 reference purposes only. Catalog 1308242 Issued 3-03 (PDF Rev. 3-04) Model 98 - 3100 Definite Purpose Contactor 3-pole, 20-40 FLA AC Coil File E75492 File EN60947-4-1:1991 IEC 947-4-1 Users should thoroughly review the technical data before selecting a product part number ...

Page 2

... Ordering Information Typical Part No. 1. Series: 3100 = 3-pole, 20-40 FLA contactor 2.Packaging Individual Pack - = Bulk Pack A-ZZZ = Customer specific information (assigned by factory) 3.Pole Configuration Form X (3PST-NO-DM) 4.Coil Voltage (50/60 Hz.): Q = 24VAC U = 208/240VAC H = 480VAC T = 120VAC V = 277VAC I = 24VAC, molded 5.Contact Ratings (Inductive FLA ...

Related keywords