1393808-4 TE Connectivity, 1393808-4 Datasheet

no-image

1393808-4

Manufacturer Part Number
1393808-4
Description
RELAY GP DPDT 5A 125VDC
Manufacturer
TE Connectivity
Series
V23154, AXICOMr
Datasheet

Specifications of 1393808-4

Contact Form
DPDT (2 Form C)
Contact Rating (current)
5A
Switching Voltage
125VAC, 150VDC - Max
Turn On Voltage (max)
81 VDC
Relay Type
General Purpose
Coil Type
Non Latching
Coil Current
6mA
Coil Voltage
125VDC
Mounting Type
Socketable
Termination Style
Plug In
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
V23154D703F104
n
n
n
n
n
n
Typical applications
Measurement and control equipment, control equipment in nuclear
powerplant, press controls with high safety requirements (force-guided
springs), telecommunications
U
09-2010, Rev. 0910
www.tycoelectronics.com
© 2010 Tyco Electronics Ltd.
Contact Data
Product code block 3
Contact arrangement
Max. switching voltage
Rated current
Limiting continuous current
Breaking capacity max.
Contact material
Contact style
Frequency of operation, without load, max. 50 ops./s
Operate / release time typ.
Mechanical endurance
Max. DC breaking capacity, contact sets B1xx, C1xx
Multi purpose relay
Highly reliable
Great variety of contact arrangements and materials to meet
specific applications
Contacts for signal loads and currents up to 5 A
DC coil, operating voltage 1.5VDC to 125VDC; AC, latching and non-
latching coils on request
Sockets for easy and quick mounting of relays
at max. ambient temperature
see DC load breaking capacity curve below 50VA
100
150
120
V _
80
60
30
40
50
0,3
safe breaking, no stationary arc
contact material Ag, gold flashed
0,4
0,5
0,6
Signal Relays
Cradle N Relay V23154/V23162
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
silver, gold-flashed
B104/B110/B112
0,8
70 W
40 W
single contact
app. 10
max. 4 form A (4 CO)contacts, 2 form B (2 NC) contacts or 6 form A (6 NO) contacts (see product code table)
35 to 70W
150VDC
125VAC
7.5/3ms
2A
2A
1
DC current [A]
7
ops.
1,5
B604/B610/B612
I
single contact
app. 10
50 ops./s
5W, 5VA
7.5/3ms
36VDC
30VAC
gold F
0.2A
2A
-
2A
7
ops.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.tycoelectronics.com/definitions
U
Max. DC breaking capacity, contact sets F1xx
250
V _
200
150
100
80
60
50
40
30
20
0,2
safe breaking, no stationary arc
contact material Ag, gold flashed
bifurcated contacts
silver, gold-flashed
C104/C110/C112
app. 10
35 to 70W
50 ops./s
150VDC
7.5/3ms
125VAC
0,3
50VA
2A
2A
7
0,4
ops.
0,5
0,6
bifurcated contacts
app. 10
0,8
C404/C410
50 ops./s
5W, 5VA
7.5/3ms
36VDC
30VAC
gold F
0.2A
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
2A
-
100 W
50 W
7
140 W
ops.
1,5
DC current [A]
2
silver, gold-flashed
single contact
app. 10
F104 to F107
50 to 140W
10 ops./s
150VDC
125VAC
7.5/3ms
Axicom
500VA
3
5A
5A
I
7
ops.
4
5A
1

Related parts for 1393808-4

1393808-4 Summary of contents

Page 1

... Contacts for signal loads and currents coil, operating voltage 1.5VDC to 125VDC; AC, latching and non- n latching coils on request Sockets for easy and quick mounting of relays n Typical applications Measurement and control equipment, control equipment in nuclear powerplant, press controls with high safety requirements (force-guided ...

Page 2

... Signal Relays Cradle N Relay V23154/V23162 Coil Data Magnetic system Coil voltage range typ. 800mW power consumption Max. coil temperature Thermal resistance Coil versions, DC coil, monostable Coil Rated Operate/Limiting code voltage voltage 1) VDC VDC 702 1.1 - 711 5 - 712 7 - 715 9 - 716 10 - 717 12 - 719 ...

Page 3

... Signal Relays Cradle N Relay V23154/V23162 Terminal assignment Size I 2 form C (2 CO) 2 form A (2 NO) V231xx-xxxxx-Bx04 V231xx-xxxxx-F105 V231xx-xxxxx-Cx04 Size II 6 form A (6 NO) 4 form C (4 CO) V231xx-xxxxx-Bx12 V231xx-xxxxx-Bx10 V231xx-xxxxx-Cx12 Dimensions V23154-C0xx, size I type V23162-A0xx, size I type 09-2010, Rev. 0910 Datasheets and product specification ac- cording to IEC 61810-1 and to be used only www ...

Page 4

... Signal Relays Cradle N Relay V23154/V23162 Dimensions V23154-Mxxx, size I type V23154-Nxxx, size II type Instructions for Impulse Operation The maximum voltage stated in the part code table can be increased for impulse operation as follows Impuls II tamb U Maximum continuous voltage at ambient temperature t II tamb q Factor The impulse voltage must not exceed 80% of the test voltage (winding/ frame or winding/winding ...

Page 5

... Signal Relays Cradle N Relay V23154/V23162 Product code structure Type V23154 Cradle N Relay, dust protected V23162 Cradle N Relay, hermetically sealed Version V23154 types C0 Size I, for plug-in and screw fixing, hand solder terminals silver-plated, with earth terminal, dust-protected (V23154) D0 Size II, for plug-in and screw fixing, hand solder terminals silver-plated, with earth terminal, dust-protected (V23154) ...

Page 6

... 4-1393808-3 4-1393808-5 4-1393808-6 3-1393807-0 4-1393808-9 5-1393808-0 8-1422029-2 5-1393808-3 5-1393808-6 5-1393808-7 6-1393808-1 1413000-3 7-1393807-5 7-1393807-8 6-1393808-5 6-1393808-6 6-1393808-9 7-1393808-0 7-1393808-1 7-1393808-3 3-1393807-7 4-1393807-1 4-1393807-2 4-1393807-3 8-1393808-3 8-1393808-4 9-1393808-2 9-1393808-3 9-1393808-5 9-1393808-6 9-1393808-9 8-1393807-2 8-1393807-3 1-1393809-4 1-1393809-5 2-1393809-1 2-1393809-2 2-1393809-3 3-1393809-2 3-1393809-4 3-1393809-8 ...

Page 7

... 1393808-8 1-1393808-6 1-1393808-7 6-1393809-2 6-1393809-4 1393808-1 3-1393808-2 3-1393808-6 3-1393807-1 5-1393808-4 6-1393808-2 7-1393808-6 4-1393807-4 1393809-1 2-1393809-4 4-1393809-4 6-1393809-0 2-1393807-2 1-1393808-9 6-1393809-5 1393808-4 1-1393810-8 2-1393810-1 2-1393810-2 2-1393810-3 2-1393810-4 2-1393810-5 2-1393810-6 2-1393810-7 2-1393810-9 3-1393810-0 3-1393810-4 3-1393810-5 2-1419172-5 3-1393810-6 3-1393810-8 4-1393810-0 1-1393810-5 1-1393810-4 2-1422030-5 3-1393810-2 ...

Page 8

... Signal Relays Cradle N Relay V23154/V23162 Product code Version V23154-N0XX, standard, size II V23154-N0712-B110 Standard, size II V23154-N0716-C110 Standard, size II V23154-N0717-B110 Standard, size II V23154-N0719-B110 Standard, size II V23154-N0720-B110 Standard, size II V23154-N0720-B610 Standard, size II V23154-N0720-C110 Standard, size II V23154-N0720-C112 Standard, size II V23154-N0720-C410 Standard, size II V23154-N0721-B110 Standard, size II ...

Page 9

... Signal Relays Cradle N Relay V23154/V23162 Product code Version V23162-A0XX, 5A, size I V23162-A0702-F106 5A, size I V23162-A0717-F105 5A, size I V23162-A0717-F106 5A, size I V23162-A0721-F105 5A, size I V23162-A0721-F106 5A, size I V23162-A0722-F105 5A, size I V23162-A0726-F106 5A, size I V23162-A0404-F106 5A, size I V23162-A0704-F105 5A, size I V23162-A0704-F106 5A, size I V23162-A0703-F106 5A, size I V23162-B0XX, standard, size II V23162-B0712-B110 Standard, size II V23162-B0715-C110 Standard, size II ...

Page 10

... Signal Relays Cradle N Relay V23154/V23162 Product code Version V23162-H0XX, 5A, size II V23162-H0712-F104 5A, size II V23162-H0719-F104 5A, size II V23162-H0721-F104 5A, size II V23162-H0721-F107 5A, size II V23162-H0722-F104 5A, size II V23162-H0704-F104 5A, size II V23162-H0703-F104 5A, size II 10 09-2010, Rev. 0910 www.tycoelectronics.com © 2010 Tyco Electronics Ltd. (Continued) Coil Operate/Lim. Arrangement Contacts 7VDC 3.6/10.5VDC ...

Related keywords