3-794680-8 TE Connectivity, 3-794680-8 Datasheet
3-794680-8
Specifications of 3-794680-8
Related parts for 3-794680-8
3-794680-8 Summary of contents
Page 1
... SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the 3 mm Micro MATE-N- LOK* connector family. This connector family has wire-to-board and wire-to-wire configurations. The connectors are available positions in a double row configuration, and positions in a single row configuration, with both configurations using AWG wire. ...
Page 2
... Rev D Requirement Meets requirements of product drawing. Meets visual requirements. ELECTRICAL 20 milliohms maximum. 1000 megohms initial. 100 megohms final. 1 minute hold with no breakdown, flashover milliampere maximum leakage. 30° C maximum temperatur e rise at specified current (100% energized). Wire Size Connector Amperes (AWG) Position 4.25 28 ...
Page 3
... EIA-364-29. Apply an axial load of 1.4 kg [3.1 lb] to contacts at a rate of 0. lb] per second and hold for 6 seconds. EIA-364-29. Apply an axial load of 1. lb] to contacts at a rate of 0. lb] per second and hold for 6 seconds ...
Page 4
... Subject specimens to 5 cycles between -40 and 105° C. EIA-364-31, Method III. Subject specimens to 10 cycles (10 days) between 25 and 65° 100% RH. EIA-364-17, Method A, Test Condition 4, Test Time Condition C. Subject mated specimens to 105° C for 500 hours. EIA-364-65, Class IIA. Subject mated specimens to environmental Class IIA for 20 days ...
Page 5
... Test omitted when testing wire-to-wire connectors. (d) The fourth test in this sequence will be either humidity/temperature cycling for tin plated specimens or mixed flowing gas for gold plated specimens. Precondition specimens with 10 cycles of durability. Rev D Test Group ( Test Sequence ( 3,7 2,6 3,7 4,8 3 10 Figure 2 108-1836 ...
Page 6
... Quality Conformance Inspection The applicable quality inspection plan shall specify the sampling acceptable quality level to be used. Dimensional and functional requirements shall be in accordance with the applicable product drawing and this specification. Rev D 108-1836 ...
Page 7
... Resistance due to X length of wire removed from all readings. NOTE Vibration & Mechanical Shock Mounting Fixture Rev D Figure 3 Termination Resistance Measurement Points Figure 4 108-1836 ...