AD8505ARJZ-RL Analog Devices Inc, AD8505ARJZ-RL Datasheet
AD8505ARJZ-RL
Specifications of AD8505ARJZ-RL
Related parts for AD8505ARJZ-RL
AD8505ARJZ-RL Summary of contents
Page 1
FEATURES PSRR: 100 dB minimum CMRR: 105 dB typical Very low supply current: 20 μA per amplifier maximum 1 single supply or ±0 ±2.5 V dual supply Rail-to-rail input/output Low noise: 45 nV/√Hz at ...
Page 2
AD8505/AD8506/AD8508 TABLE OF CONTENTS Features .............................................................................................. 1 Applications ....................................................................................... 1 General Description ......................................................................... 1 Pin Configurations ........................................................................... 1 Revision History ............................................................................... 2 Specifications ..................................................................................... 3 Electrical Characteristics—1.8 V Operation ............................ 3 Electrical Characteristics—5 V Operation................................ 4 Absolute Maximum Ratings ............................................................ ...
Page 3
SPECIFICATIONS ELECTRICAL CHARACTERISTICS—1.8 V OPERATION 25° Table 1. Parameter INPUT CHARACTERISTICS Offset Voltage Input Bias Current Input Offset Current Input Voltage Range Common-Mode Rejection ...
Page 4
AD8505/AD8506/AD8508 ELECTRICAL CHARACTERISTICS—5 V OPERATION / 25° 100 kΩ to GND, unless otherwise noted Table 2. Parameter INPUT CHARACTERISTICS Offset Voltage Input Bias Current ...
Page 5
ABSOLUTE MAXIMUM RATINGS Table 3. Parameter Supply Voltage Input Voltage 1 Input Current 2 Differential Input Voltage Output Short-Circuit Duration to GND Storage Temperature Range Operating Temperature Range Junction Temperature Range Lead Temperature (Soldering, 60 sec) 1 Input pins have ...
Page 6
AD8505/AD8506/AD8508 TYPICAL PERFORMANCE CHARACTERISTICS T = 25°C, unless otherwise noted. A 250 200 150 100 50 0 –4 –3 –2 – (mV) OS Figure 7. Input Offset Voltage Distribution ...
Page 7
T = 25°C, unless otherwise noted. A –115 –120 –125 –130 –135 –140 0 0.2 0.4 0.6 0.8 1.0 V (V) CM Figure 13. Input Offset Voltage vs. Input Common-Mode Voltage 600 550 500 450 400 350 300 250 200 ...
Page 8
AD8505/AD8506/AD8508 T = 25°C, unless otherwise noted. A 10k 100 V – 0.1 0.001 0.01 0.1 LOAD CURRENT (mA) Figure 19. Output Voltage to Supply Rail vs. Load Current 14 ...
Page 9
T = 25°C, unless otherwise noted. A 120 100 PHASE GAIN 20 0 –20 GAIN 0pF –40 L PHASE 0pF L –60 GAIN 50pF L PHASE 50pF –80 L ...
Page 10
AD8505/AD8506/AD8508 T = 25°C, unless otherwise noted. A 100 100 1k 10k FREQUENCY (Hz) Figure 31. CMRR vs. Frequency 100 PSRR– 100 ...
Page 11
T = 25°C, unless otherwise noted. A TIME (100µs/DIV) Figure 37. Large-Signal Transient Response TIME (100µs/DIV) Figure 38. Small-Signal Transient Response TIME (4s/DIV) Figure 39. Input Voltage Noise 0 1. 100kΩ ...
Page 12
AD8505/AD8506/AD8508 T = 25°C, unless otherwise noted. A –40 100kΩ –50 10kΩ –60 –70 –80 –90 –100 –110 –120 100 1k FREQUENCY (Hz) Figure 43. Channel Separation vs. Frequency 1.5V p-p IN 10k 100k ...
Page 13
THEORY OF OPERATION The AD8505/AD8506/AD8508 are unity-gain, stable, CMOS, rail- to-rail input/output operational amplifiers designed to optimize performance in current consumption, PSRR, CMRR, and zero crossover distortion, all embedded in a small package. The typical offset voltage is 500 μV, ...
Page 14
AD8505/AD8506/AD8508 The charge pump has been carefully designed so that switching noise components at any frequency, both within and beyond the amplifier bandwidth, are much lower than the thermal noise floor. Therefore, the spurious-free dynamic range (SFDR) is limited only ...
Page 15
APPLICATIONS INFORMATION PULSE OXIMETER CURRENT SOURCE A pulse oximeter is a noninvasive medical device used for con- tinuously measuring the percentage of hemoglobin (Hb) saturated with oxygen and the pulse rate of a patient. Hemoglobin that is carrying oxygen (oxyhemoglobin) ...
Page 16
AD8505/AD8506/AD8508 FOUR-POLE, LOW-PASS BUTTERWORTH FILTER FOR GLUCOSE MONITOR There are several methods of glucose monitoring: spectroscopic absorption of infrared light in the 2 μm to 2.5 μm range, reflec- tance spectrophotometry, and the amperometric type using electrochemical strips with glucose ...
Page 17
OUTLINE DIMENSIONS 1.70 1.60 1.50 1.30 1.15 0.90 0.15 MAX 0.05 MIN 0.945 0.905 0.865 BALL A1 IDENTIFIER TOP VIEW (BALL SIDE DOWN) 3.00 2.90 2. 3.00 2.80 2. 0.95 BSC 1.90 BSC 0.20 MAX ...
Page 18
AD8505/AD8506/AD8508 IDENTIFIER 1.460 1.420 SQ 1.380 BALL 1 IDENTIFIER TOP VIEW 3.20 3.00 2.80 5. 3.20 4.90 3.00 4.65 1 2.80 4 PIN 1 0.65 BSC 0.95 15° MAX 0.85 1.10 MAX 0.75 0.15 0.23 6° 0.40 0.05 ...
Page 19
PIN 1 0.65 BSC 1.05 1.00 0.80 0.15 0.05 0.30 COPLANARITY 0.19 0.10 COMPLIANT TO JEDEC STANDARDS MO-153-AB-1 Figure 55. 14-Lead Thin Shrink Small Outline Package [TSSOP] 1.50 1.46 1.42 BALL 1 ...
Page 20
... AD8505/AD8506/AD8508 ORDERING GUIDE 1 Model Temperature Range AD8505ARJZ-R2 −40°C to +125°C AD8505ARJZ-R7 −40°C to +125°C AD8505ARJZ-RL −40°C to +125°C AD8505ACBZ-R7 −40°C to +125°C AD8505ACBZ-RL −40°C to +125°C AD8506ACBZ-REEL −40°C to +125°C AD8506ACBZ-REEL7 −40°C to +125°C AD8506ARMZ − ...