AD9522-5/PCBZ Analog Devices Inc, AD9522-5/PCBZ Datasheet - Page 25

no-image

AD9522-5/PCBZ

Manufacturer Part Number
AD9522-5/PCBZ
Description
12/24 Channel Clock Gen 2,0GH
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD9522-5/PCBZ

Main Purpose
Timing, Clock Generator
Embedded
No
Utilized Ic / Part
AD9522-5
Primary Attributes
12 LVDS/24 CMOS Outputs
Secondary Attributes
I²C & SPI Interfaces
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
THEORY OF OPERATION
OPERATIONAL CONFIGURATIONS
The AD9522 can be configured in several ways. These
configurations must be set up by loading the control registers
(see Table 43 to Table 54). Each section or function must be
individually programmed by setting the appropriate bits in the
corresponding control register or registers. When the desired
configuration is programmed, the user can store these values in
the on-board EEPROM to allow the part to power up in the
desired configuration without user intervention.
Mode 1: Clock Distribution or External VCO < 1600 MHz
When the external clock source to be distributed or the external
VCO/VCXO is <1600 MHz, a configuration that bypasses the
VCO divider can be used. This is the only difference from Mode 2.
Bypassing the VCO divider limits the frequency of the clock
source to <1600 MHz (due to the maximum input frequency
allowed at the channel dividers).
For clock distribution applications where the external clock is
<1600 MHz, the register settings shown in Table 19 should be used.
Table 19. Settings for Clock Distribution < 1600 MHz
Register
0x010[1:0] = 01b
0x1E1[0] = 1b
Description
PLL asynchronous power-down (PLL off )
Bypass the VCO divider as the source for
the distribution section
Rev. 0 | Page 25 of 76
When using the PLL with an external VCO < 1600 MHz, the PLL
must be turned on.
Table 20. Settings for Using the PLL with External VCO <
1600 MHz
Register
0x1E1[0] = 1b
0x010[1:0] = 00b
An external VCO/VCXO requires an external loop filter that
must be connected between CP and the tuning pin of the VCO/
VCXO. This loop filter determines the loop bandwidth and stability
of the PLL. Make sure to select the proper PFD polarity for the
VCO/VCXO being used.
Table 21. Setting the PFD Polarity
Register
0x010[7] = 0b
0x010[7] = 1b
Description
PFD polarity positive (higher control voltage
produces higher frequency)
PFD polarity negative (higher control voltage
produces lower frequency)
Description
Bypass the VCO divider as the source for
the distribution section
PLL normal operation (PLL on) along
with other appropriate PLL settings in
0x010 to 0x01F
AD9522-5

Related parts for AD9522-5/PCBZ