ADT7470ARQZ-REEL7 Analog Devices Inc, ADT7470ARQZ-REEL7 Datasheet - Page 32

IC,Motor Controller,SSOP,16PIN

ADT7470ARQZ-REEL7

Manufacturer Part Number
ADT7470ARQZ-REEL7
Description
IC,Motor Controller,SSOP,16PIN
Manufacturer
Analog Devices Inc
Datasheet

Specifications of ADT7470ARQZ-REEL7

Function
Fan Control, Temp Monitor
Topology
ADC, Comparator, Fan Speed Control, Register Bank
Sensor Type
External
Sensing Temperature
External Sensor
Output Type
I²C™
Output Alarm
No
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-QSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
EVAL-ADT7470EBZ - BOARD EVALUATION FOR ADT7470
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADT7470ARQZ-REEL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADT7470
Table 34. Register 0x43. Fan Pulses per Revolution Register (Power-On Default = 0x55).
Bit Name
[1:0] Fan 1
[3:2] Fan 2
[5:4] Fan 3
[7:6] Fan 4
Table 35. Register 0x44 to Register 0x57. Temperature Limit Registers.
Register Address
0x44
0x45
0x46
0x47
0x48
0x49
0x4A
0x4B
0x4C
0x4D
0x4E
0x4F
0x50
0x51
0x52
0x53
0x54
0x55
0x56
0x57
Exceeding any of the temperature limits shown in Table 35 by 1°C causes the appropriate status bit to be set in the interrupt status registers.
High limits: An interrupt is generated when a value exceeds its high limit (> comparison).
Low limits: An interrupt is generated when a value is equal to or below its low limit (≤ comparison).
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Description
Sets the number of pulses to be counted when measuring Fan 1 speed.
Can be used to determine fan’s pulses per revolution number for unknown fan type.
Pulses Counted
00 = 1
01 = 2 (default)
10 = 3
11 = 4
Sets the number of pulses to be counted when measuring Fan 2 speed.
Can be used to determine fan’s pulses per revolution number for unknown fan type.
Pulses Counted
00 = 1
01 = 2 (default)
10 = 3
11 = 4
Sets the number of pulses to be counted when measuring Fan 3 speed.
Can be used to determine fan’s pulses per revolution for unknown fan type.
Pulses Counted
00 = 1
01 = 2 (default)
10 = 3
11 = 4
Sets the number of pulses to be counted when measuring Fan 4 speed. Can be used to determine fan’s
pulses per revolution for unknown fan type.
Pulses Counted
00 = 1
01 = 2 (default)
10 = 3
11 = 4
Description
Temperature 1 low limit
Temperature 1 high limit
Temperature 2 low limit
Temperature 2 high limit
Temperature 3 low limit
Temperature 3 high limit
Temperature 4 low limit
Temperature 4 high limit
Temperature 5 low limit
Temperature 5 high limit
Temperature 6 low limit
Temperature 6 high limit
Temperature 7 low limit
Temperature 7 high limit
Temperature 8 low limit
Temperature 8 high limit
Temperature 9 low limit
Temperature 9 high limit
Temperature 10 low limit
Temperature 10 high limit
Rev. C | Page 32 of 40
Power-On Default
0x81
0x7F
0x81
0x7F
0x81
0x7F
0x81
0x7F
0x81
0x7F
0x81
0x7F
0x81
0x7F
0x81
0x7F
0x81
0x7F
0x81
0x7F

Related parts for ADT7470ARQZ-REEL7