Specifications of ADUM1412BRWZ-RL

Inputs - Side 1/side 2
2/2
Number Of Channels
4
Isolation Rating
2500Vrms
Voltage - Supply
2.7 V ~ 5.5 V
Data Rate
10Mbps
Propagation Delay
30ns
Output Type
Logic
Package / Case
16-SOIC (0.300", 7.5mm Width)
Operating Temperature
-40°C ~ 105°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM1412BRWZ-RL
Manufacturer:
ADI
Quantity:
8 895
DIN V VDE V 0884-10 (VDE V 0884-10): 2006-12 INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation within the safety limit data only. Maintenance of the safety data is ensured by
protective circuits. The asterisk (*) marked on packages denotes DIN V VDE V 0884-10 approval.
Table 7.
Description
Installation Classification per DIN VDE 0110
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method B1
Input-to-Output Test Voltage, Method A
Highest Allowable Overvoltage
Safety-Limiting Values
Insulation Resistance at T
Figure 4. Thermal Derating Curve, Dependence of Safety-Limiting Values
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
After Environmental Tests Subgroup 1
Case Temperature
Side 1 Current
Side 2 Current
After Input and/or Safety Test Subgroup 2
and Subgroup 3
350
300
250
200
150
100
50
0
0
with Case Temperature per DIN V VDE V 0884-10
50
CASE TEMPERATURE (°C)
SIDE #1
S
SIDE #2
100
150
Conditions
V
partial discharge < 5 pC
V
V
Transient overvoltage, t
Maximum value allowed in the event of a failure;
see Figure 4
V
IORM
IORM
IORM
IO
= 500 V
× 1.875 = V
× 1.6 = V
× 1.2 = V
200
Rev. H | Page 11 of 24
PR
PR
, t
, t
PR
m
m
, 100% production test, t
= 60 sec, partial discharge < 5 pC
= 60 sec, partial discharge < 5 pC
TR
= 10 seconds
RECOMMENDED OPERATING CONDITIONS
Table 8.
Paramete
Operating Temperature
Supply Voltages
Input Signal Rise and Fall Times
1
All voltages are relative to their respe ive ground. S
and Magnetic Field Immunity section for information on immunity to external
magnetic fields.
r
ADuM1410/ADuM1411/ADuM1412
m
1
= 1 sec,
Symbol
V
V
V
V
T
I
I
R
S1
S2
S
S
IORM
PR
PR
TR
ct
Symbol
T
V
A
DD
1
, V
DD2
Characteristic
I to IV
I to III
I to II
40/105/21
2
560
1050
896
4000
150
265
335
>10
672
9
ee t
Min
−40
2.7
he D
C Corr
Max
+105
5.5
1.0
ectn
Unit
V peak
V peak
V peak
V peak
V peak
°C
mA
mA
Ω
ess
Unit
°C
V
ms