Q6025J6 Littelfuse Inc, Q6025J6 Datasheet - Page 8

Triacs 600V 25A 80-80-80mA

Q6025J6

Manufacturer Part Number
Q6025J6
Description
Triacs 600V 25A 80-80-80mA
Manufacturer
Littelfuse Inc
Datasheet

Specifications of Q6025J6

Rated Repetitive Off-state Voltage Vdrm
600 V
Breakover Current Ibo Max
250 A
On-state Rms Current (it Rms)
25 A
Off-state Leakage Current @ Vdrm Idrm
0.05 mA
Gate Trigger Voltage (vgt)
1.3 V
Gate Trigger Current (igt)
80 mA
Holding Current (ih Max)
100 mA
Forward Voltage Drop
1.8 V
Mounting Style
Through Hole
Package / Case
TO-218X
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Repetitive Peak Forward Blocking Voltage
600 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Q6025J6
Manufacturer:
TECCOR
Quantity:
20 000
Alternistor Triacs
Figure E4.7 Normalized DC Gate Trigger Voltage for all Quadrants
Figure E4.8 Normalized DC Gate Trigger Current for all Quadrants
Figure E4.9 Normalized DC Holding Current versus Case Temperature
http://www.littelfuse.com
+1 972-580-7777
versus Case Temperature
versus Case Temperature
4.0
3.0
2.0
1.0
4.0
3.0
2.0
1.0
0
-65
0
2.0
1.5
1.0
-65
.5
0
-65
-40
-40
-40
Case Temperature (T
Case Temperature (T
Case Temperature (T
INITIAL ON-STATE CURRENT
= 400 mA dc 16 A to 40 A Devices
= 100 mA dc 6 to 12A Devices
-15
-15
-15
+25
+25
+25
+65
+65
+65
C
C
C
) – ˚C
) – ˚C
) – ˚C
+125
+125
+125
E4 - 8
Figure E4.10 Peak Surge Current versus Surge Current Duration
Figure E4.11 Peak Surge Current versus Surge Current Duration
Figure E4.12 Turn-on Time versus Gate Trigger Current (Typical)
1000
400
300
250
200
100
80
60
50
40
30
20
10
200
120
100
80
60
50
40
10
30
20
8
6
5
4
3
2
1
1
10
(6 A to 12 A)
(16 A to 40 A)
1
8
6
4
2
0
Notes:
1) Gate control may be lost during and
2) Overload may not be repeated until
SUPPLY FREQUENCY: 60 Hz Sinusoidal
LOAD: Resistive
RMS ON-STATE CURRENT [I T(RMS) ]: Maximum
0
immediately following surge current
interval.
junction temperature has returned to
steady-state rated value.
Rated Value at Specified Case Temperature
2
I
GT
Surge Current Duration – Full Cycles
3 4 5 6 8 10
Surge Current Duration – Full Cycles
DC Gate Trigger Current ( I
100
= 50 mA
10
I
GT
SUPPLY FREQUENCY: 60Hz Sinusoidal
LOAD: Resistive
RMS ON-STATE CURRENT [I
Rated Value at Specified Case Temperature
200
= 10 mA to 35 mA
20
I
GT
30 40
= 80 to 100 mA
300
60 80 100
Thyristor Product Catalog
Notes:
1) Gate control may be lost during and
2) Overload may not be repeated until
immediately following surge current
interval
junction temperature has returned
to steady state rated value.
100
GT
©2004 Littelfuse, Inc.
) – mA
200
400
T(RMS)
300
]: Maximum
Data Sheets
600
500
1000
1000

Related parts for Q6025J6