LTC6803HG-2#TRPBF-ES Linear Technology, LTC6803HG-2#TRPBF-ES Datasheet - Page 20

no-image

LTC6803HG-2#TRPBF-ES

Manufacturer Part Number
LTC6803HG-2#TRPBF-ES
Description
SC-Special Function, Battery Stack Monitor, Addressable SPI
Manufacturer
Linear Technology
Type
Battery Monitoringr
Datasheet

Specifications of LTC6803HG-2#TRPBF-ES

Battery Type
Li-Ion
Operating Supply Voltage (min)
4V
Operating Temp Range
-40C to 125C
Package Type
SSOP
Mounting
Surface Mount
Pin Count
44
Operating Temperature Classification
Automotive
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LTC6803HG-2#TRPBF-ESLTC6803HG-2
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Company:
Part Number:
LTC6803HG-2#TRPBF-ESLTC6803HG-2#PBF
Manufacturer:
LT
Quantity:
210
Company:
Part Number:
LTC6803HG-2#TRPBF-ESLTC6803HG-2#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Company:
Part Number:
LTC6803HG-2#TRPBF-ESLTC6803HG-2#TRPBF
Manufacturer:
LT
Quantity:
200
LTC6803-2/LTC6803-4
OPERATION
Toggle Polling: Toggle polling allows a robust determina-
tion both of device states and of the integrity of the con-
nections between the devices in a stack. Toggle polling is
enabled when the LVLPL bit is low. After entering a polling
command, the data out line will be driven by the slave
devices based on their status. When polling for the ADC
converter status, data out will be low when any device is
busy performing an ADC conversion and will toggle at
1kHz when no device is busy. Similarly, when polling for
interrupt status, the output will be low when any device
has an interrupt condition and will toggle at 1kHz when
none has an interrupt condition.
Toggle Polling—Address Polling: The addressed device
drives the SDO line based on its state alone—low for busy/
in interrupt, toggling at 1kHz for not busy/not in interrupt.
Toggle Polling—Parallel Broadcast Polling: No part ad-
dress is sent, so all devices respond simultaneously. If a
device is busy/in interrupt, it will pull SDO low. If a device
is not busy/not in interrupt, then it will release the SDO line
(TOS = 0) or attempt to toggle the SDO line at 1kHz (TOS
= 1).The master controller pulls CSBI high to exit polling.
20
SCKI
CSBI
SDO
SCKI
CSBI
SDI
SDO
SDI
Figure 6. Transmission Format (PLADC Conversion or PLINT)
Figure 5. Transmission Format (ADC Conversion and Poll)
MSB (CMD) BIT6 (CMD)
MSB (CMD) BIT6 (CMD)
LSB (PEC)
LSB (PEC)
Level Polling: Level polling is enabled when the LVLPL
bit is high. After entering a polling command, the data
out line will be driven by the slave devices based on their
status. When polling for the ADC converter status, data
out will be low when any device is busy performing an
ADC conversion and will be high when no device is busy.
Similarly, when polling for interrupt status, the output will
be low when any device has an interrupt condition and will
be high when none has an interrupt condition.
Level Polling—Address Polling: The addressed device
drives the SDO line based on its state alone—pulled low
for busy/in interrupt, released for not busy/not in interrupt.
Level polling—Parallel Broadcast Polling: No part address
is sent, so all devices respond simultaneously. If a device
is busy/in interrupt, it will pull SDO low. If a device is not
busy/not in interrupt, then it will release the SDO line. If
any device is busy or in interrupt the SDO signal will be
low. If all devices are not busy/not in interrupt, the SDO
signal will be high. The master controller pulls CSBI high
to exit polling.
t
CYCLE
TOGGLE OR LEVEL POLL
TOGGLE OR LEVEL POLL
680324 F06
680324 F05
680324f

Related parts for LTC6803HG-2#TRPBF-ES