ATV61HC20Y SQUARE D, ATV61HC20Y Datasheet

no-image

ATV61HC20Y

Manufacturer Part Number
ATV61HC20Y
Description
ALTIVAR 61 DRIVE 200 HP 575/690 VOLT
Manufacturer
SQUARE D
Datasheet
Product data sheet
Characteristics
Mar 30, 2012
ATV61HC20Y
variable speed drive ATV61 - 200kW / 690V -
200HP / 575V - IP20
Main
Range of product
Product or component
type
Product specific appli-
cation
Component name
Motor power kW
Motor power hp
Power supply voltage
Supply number of
phases
Line current
EMC filter
Assembly style
Maximum prospective
line Isc
Maximum transient cur-
rent
Nominal switching fre-
quency
Switching frequency
Asynchronous motor
control
Synchronous motor
control profile
Communication port
protocol
Type of polarization
Option card
Altivar 61
Variable speed drive
Pumping and ventilation machine
ATV61
160 kW 3 phases at 500 V
200 kW 3 phases at 690 V
200 hp 3 phases at 575 V
500...690 V (- 15...10 %)
3 phases
197 A for 600 V 3 phases 160 kW / 200 hp
199 A for 690 V 3 phases 160 kW / 200 hp
218 A for 500 V 3 phases 160 kW / 200 hp
Level 3 EMC filter
With heat sink
35 kA 3 phases
288 A for 60 s 3 phases
2.5 kHz
2.5...4.9 kHz adjustable
2.5...4.9 kHz with derating factor
Voltage/Frequency ratio, 2 points
Voltage/Frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/Frequency ratio - Energy Saving, quadratic
U/f
Vector control without sensor, standard
CANopen
Modbus
No impedance for Modbus
APOGEE FLN communication card
BACnet communication card
CC-Link communication card
Controller inside programmable card
DeviceNet communication card
Ethernet/IP communication card
Fipio communication card
I/O extension card
Interbus-S communication card
LonWorks communication card
METASYS N2 communication card
Modbus Plus communication card
Modbus TCP communication card
Modbus/Uni-Telway communication card
Multi-pump card
Profibus DP communication card
Profibus DP V1 communication card
1

Related parts for ATV61HC20Y

ATV61HC20Y Summary of contents

Page 1

... Product data sheet Characteristics Mar 30, 2012 ATV61HC20Y variable speed drive ATV61 - 200kW / 690V - 200HP / 575V - IP20 Main Range of product Altivar 61 Product or component Variable speed drive type Product specific appli- Pumping and ventilation machine cation Component name ATV61 Motor power kW 160 kW 3 phases at 500 V ...

Page 2

Complementary Product destination Power supply voltage limits Power supply frequency Power supply frequency limits Continuous output current Speed drive output frequency Speed range Speed accuracy Torque accuracy Transient overtorque Braking torque Regulation loop Motor slip compensation Diagnostic Output voltage Electrical ...

Page 3

Discrete output number Discrete output type Maximum response time Minimum switching current Maximum switching current Discrete input number Discrete input type Discrete input logic Acceleration and deceleration ramps Braking to standstill Protection type Insulation resistance Frequency resolution Type of connector ...

Page 4

Environment Noise level Dielectric strength Electromagnetic compatibility Standards Product certifications Pollution degree Degree of proctection Vibration resistance Shock resistance Relative humidity Ambient air temperature for operation Ambient air temperature for storage Operating altitude RoHS EUR status RoHS EUR conformity date ...

Page 5

... Option cards: I/O extension cards, communication cards or "Controller Inside” programmable card. Dimensions with 2 Option Cards (1) Dimensions 340 392 285 Dimensions in in 13.39 15.43 11.22 (1) Option cards: I/O extension cards, communication cards or "Controller Inside” programmable card. ATV61HC20Y 285 920 150 11.22 36.22 5. 920 ...

Page 6

... To ensure proper air circulation in the drive: ● Fit ventilation grilles. ● Ensure that there is sufficient ventilation. If there is not, install a forced ventilation unit with a filter. The openings and/or fans must provide a flow rate at least equal to that of the drive fans (refer to the product characteristics). 6 ATV61HC20Y X1 in in. 5. in. 5.91 ...

Page 7

Use special filters with IP 54 protection. ● Remove the blanking cover from the top of the drive. Dust and Damp Proof Metal Enclosure (IP 54) The drive must be mounted in a dust and damp proof enclosure in ...

Page 8

... All terminals are located at the bottom of the drive. Fit interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc. Wiring Diagram Conforming to Standards EN 954-1 Category 1, IEC/EN 61508 Capacity SIL1, in Stopping Category 0 According to IEC/EN 60204-1 8 ATV61HC20Y ...

Page 9

Three-Phase Power Supply with Downstream Breaking via Switch Disconnector A1 ATV61 drive L1 DC choke Q1 Circuit-breaker Q2 Switch disconnector (Vario) (1) Line choke (three-phase), mandatory for ATV61HC11Y…HC80Y drives (except when a special transformer is used (12-pulse)). (2) For ATV61HC50N4, ...

Page 10

... ATV61 drive A2 Preventa XPS AC safety module for monitoring emergency stops and switches. One safety module can manage the “Power Removal” function for several drives on the same machine. In this case, each drive must connect its PWR terminal to its + 24 V via the safety contacts on the XPS  ...

Page 11

... ATV61 drive A2 Preventa XPS ATE safety module for monitoring emergency stops and switches. One safety module can manage the "Power Removal” (5) safety function for several drives on the same machine. In this case the time delay must be adjusted on the drive controlling the motor that requires the longest stopping time. In addition, each drive must connect its PWR terminal to its + 24  ...

Page 12

... Product data sheet Performance Curves Derating Curves The derating curves for the drive nominal current (In) depend on the temperature and the switching frequency. For intermediate temperatures (e.g. 55°C), interpolate between 2 curves. X Switching frequency 12 ATV61HC20Y ...