ATV71HD11M3X SQUARE D, ATV71HD11M3X Datasheet - Page 12

no-image

ATV71HD11M3X

Manufacturer Part Number
ATV71HD11M3X
Description
SPEED DRIVE, 15HP, 230V, ATV71
Manufacturer
SQUARE D
Datasheet
Three-Phase Power Supply, High Inertia Machine
A1
A2
(5)
F1
L1
Q1
S1
S2
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10) Standardized coaxial cable, type RG174/U according to MIL-C17 or KX3B according to NF C 93-550, external diameter
(11) Logic inputs LI1 and LI2 must be assigned to the direction of rotation: LI1 in the forward direction and LI2 in the reverse direction.
(12) There is no PO terminal on ATV71HC11Y…HC63Y drives.
(13) Optional DC choke for ATV71H•••M3, ATV71HD11M3X…HD45M3X, ATV71•075N4…•D75N4 and ATV71P•••N4Z drives. Connected in
(14) Software-configurable current (0…20 mA) or voltage (0…10 V) analog input.
(15) Reference potentiometer.
All terminals are located at the bottom of the drive. Fit interference suppressors on all inductive circuits near the drive or connected on the
same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc.
12
ATV71 drive
Preventa XPS ATE safety module for monitoring emergency stops and switches. One safety module can manage the "Power Removal”
safety function for several drives on the same machine. In this case the time delay must be adjusted on the drive controlling the motor
that requires the longest stopping time. In addition, each drive must connect its PWR terminal to its + 24 V via the safety contacts on
the XPS ATE module. These contacts are independent for each drive.
Fuse
DC choke
Circuit-breaker
Emergency stop button with 2 N/C contacts
Run button
Power supply: 24 Vdc or Vac, 115 Vac, 230 Vac.
Requests controlled stopping of the movement and activates the “Power Removal” safety function.
Line choke (three-phase), mandatory for ATV71HC11Y…HC63Y drives (except when a special transformer is used (12-pulse)).
S2: resets XPS ATE module on power-up or after an emergency stop. ESC can be used to set external starting conditions.
For stopping times requiring more than 30 seconds in category 1, use a Preventa XPS AV safety module which can provide a
maximum time delay of 300 seconds.
The logic output can be used to signal that the machine is in a safe state.
For ATV71HC40N4 drives combined with a 400 kW motor, ATV71HC50N4 and ATV71HC40Y…HC63Y, refer to the power terminal
connections diagram.
Fault relay contacts. Used for remote signalling of the drive status.
Connection of the common for the logic inputs depends on the positioning of the SW1 switch. The above diagram shows the internal
power supply switched to the “source” position (for other connection types, refer to the user guide).
2.54 mm/0.09 in., maximum length 15 m/49.21 ft. The cable shielding must be earthed.
place of the strap between the PO and PA/+ terminals. For ATV71HD55M3X, HD75M3X, ATV71HD90N4…HC50N4 drives, the choke
is supplied with the drive; the customer is responsible for connecting it.

Related parts for ATV71HD11M3X