XALD321 SQUARE D, XALD321 Datasheet

no-image

XALD321

Manufacturer Part Number
XALD321
Description
PUSH BUTTON ENCLOSURE 600VAC 10A XALB SP
Manufacturer
SQUARE D
Datasheet
Product data sheet
Characteristics
Complementary
Mar 31, 2012
Cable entry
Product weight
Resistance to high pressure washer
Positive opening
Operating travel
Operating force
Mechanical durability
Connections - terminals
Tightening torque
Shape of screw head
Contacts material
Short circuit protection
[Ith] conventional free air thermal current
[Ui] rated insulation voltage
[Uimp] rated impulse withstand voltage
[Ie] rated operational current
XALD321
dark grey station - green flush/red flush/green
flush pushbuttons Ø22
Main
Range of product
Product or component
type
Device short name
Product destination
Control station applica-
tion
Colour of base of en-
closure
Colour of cover
Material
Operator profile
Operators description
Control station compo-
sition
Marking location
Contacts operation
2 knock-outs for cable entry, clamping capacity: <= 14 mm
2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: <= 12 mm
0.299 kg
7000000 Pa at 55 °C, distance: 0.1 m
With conforming to EN/IEC 60947-5-1 appendix K
1.5 mm (NC changing electrical state)
2.6 mm (NO changing electrical state)
4.3 mm (total travel)
3.5 N (NC changing electrical state)
3.8 N (NO changing electrical state)
5000000 cycles
Screw clamp terminals: <= 2 x 1.5 mm² with cable end conforming to EN/IEC
60947-1
Screw clamp terminals: >= 1 x 0.22 mm² without cable end conforming to EN/IEC
60947-1
0.8...1.2 N.m conforming to EN/IEC 60947-1
Cross, Philips no 1
Cross, pozidriv No 1
Slotted, flat Ø 4 mm
Slotted, flat Ø 5.5 mm
Silver alloy (Ag/Ni)
10 A by gG cartridge fuse conforming to EN/IEC 60947-5-1
10 A conforming to EN/IEC 60947-5-1
600 V (degree of pollution: 3) conforming to EN/IEC 60947-1
6 kV conforming to EN/IEC 60947-1
AC-15, A600: Ue = 120 V Ie = 6 A conforming to EN/IEC 60947-5-1
AC-15, A600: Ue = 240 V Ie = 3 A conforming to EN/IEC 60947-5-1
AC-15, A600: Ue = 600 V Ie = 1.2 A conforming to EN/IEC 60947-5-1
DC-13, Q600: Ue = 125 V Ie = 0.55 A conforming to EN/IEC 60947-5-1
DC-13, Q600: Ue = 250 V Ie = 0.27 A conforming to EN/IEC 60947-5-1
DC-13, Q600: Ue = 600 V Ie = 0.1 A conforming to EN/IEC 60947-5-1
Harmony XALD
Complete control station
XALD
For XB5 Ø 22 mm control and signalling units
Three functions
Light grey RAL 7035
Dark grey RAL 7016
Polycarbonate
3 flush pushbuttons
Green 'MONTEE' 1 NO - red 'ARRET' 1 NC - green
'DESCENTE' 1 NO
1 flush pushbutton green 1 NO DESCENTE marking
1 flush pushbutton green 1 NO MONTEE marking
1 flush pushbutton red 1 NC ARRET marking
Marking on legend holder
Slow-break
1

Related parts for XALD321

XALD321 Summary of contents

Page 1

... Contacts material Short circuit protection [Ith] conventional free air thermal current [Ui] rated insulation voltage [Uimp] rated impulse withstand voltage [Ie] rated operational current Mar 31, 2012 XALD321 dark grey station - green flush/red flush/green flush pushbuttons Ø22 Main Range of product Harmony XALD Product or component ...

Page 2

Electrical durability Electrical reliability IEC 60947-5-4 Environment Protective treatment Ambient air temperature for storage Ambient air temperature for operation Class of protection against electric shock IP degree of protection NEMA degree of protection IK degree of protection Standards Product certifications ...

Related keywords