XPSAK311144P SQUARE D, XPSAK311144P Datasheet - Page 163

SAFETY RELAY 300V 5AMP PREVENTA +OPTIONS

XPSAK311144P

Manufacturer Part Number
XPSAK311144P
Description
SAFETY RELAY 300V 5AMP PREVENTA +OPTIONS
Manufacturer
SQUARE D
Datasheet

Specifications of XPSAK311144P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
45mm
Rohs Compliant
Yes
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
Selection guide
Applications
2/162
Modules
Conformity to standards
Product certifications
Number of circuits
Display
Supply voltage
Synchronization time between inputs
Input channel voltage
Module type
Pages
Safety
Additional
24 V/48 V version
24 V/48 V
or 110 V/120 V/230 V
version
Safety automation system solutions
Preventa™ safety relay modules
For Emergency stop and switch monitoring
EN 954-1 - category 3/EN/
ISO 13849-1,
EN/IEC 60204-1,
EN 1088/ISO 14119,
EN ISO 13850,
EN/IEC 60947-1 + A11,
EN/IEC 60947-5-1
UL, CSA, BG
3 N.O.
1 solid-state output for
signalling to PLC
2 LEDs
a and c 24 V
a 48 V
a 115 V
a 230 V
Unlimited
a and c 24 V/a 48 V
a 115 V/230 V
XPSAC
2/175
EN 954-1 - category 4/EN/
ISO 13849-1,
(instantaneous contacts)
EN 954-1 - category 3/
ISO 13849-1
(time delay contacts),
EN/IEC 60204-1,
EN/IEC 60947-5-1,
EN/ISO 13850,
EN 50082-2
UL, CSA, BG
2 N.O. instantaneous
+ 3 N.O. time delay
4 solid-state output for
signalling to PLC
4 LEDs
a and c 24 V
a 115 V
a 230 V
75 ms
(automatic start)
c 24 V/–
a 48 V/48 V
XPSATE
2/180
EN 954-1 - category 4/EN/
ISO 13849-1,
EN/IEC 60204-1,
DIN V VDE 801 + A1,
EN/ISO 13850,
EN 1088/ISO 14119,
EN/IEC 60947-1 A11,
EN/IEC 60947-5-1
UL, CSA, BIA
3 N.O. instantaneous
+ 3 N.O. time delay
3 solid-state outputs for
signalling to PLC
11 LEDs
c 24 V
Unlimited or 1.5 s
(depending on wiring)
c 24 V/–
XPSAV

Related parts for XPSAK311144P