D2RV-G Omron, D2RV-G Datasheet
D2RV-G
Specifications of D2RV-G
Related parts for D2RV-G
D2RV-G Summary of contents
Page 1
... N {25 gf} G: 0.98 N {100 gf} Note: These values are for the pin plunger models. OF max. 0.25 N {25 gf} D2RV-E 0.49 N {50 gf} D2RV 0.98 N {100 gf} D2RV-G 0.49 N {50 gf} D2RV-L11 0.98 N {100 gf} D2RV-L11G 0.25 N {25 gf} D2RV-L 0.49 N {50 gf} D2RV-LG 0.25 N {25 gf} D2RV-L13 0.49 N {50 gf} D2RV-L13G 0 ...
Page 2
... The values apply under the following test conditions: Ambient temperature: 20±2°C Ambient humidity: 65±5% Operating frequency: 30 operations/min 200 operations/min max. 200 operations/min max. 2 {approx. 50G} max. 2 {approx. 20G} max. 10,000,000 operations min. (200 operations/min) 3,000,000 operations min. (200 operaions/min) D2RV ...
Page 3
... D2RV-L11 D2RV Two, 3.1-dia. mounting holes or M3 screw holes 10.3±0.1 22.2±0.1 4.5 3.1 10.3 D2RV-G 0.98 N {100 gf} 4.3 3.1 10.3 D2RV-L11G 0.98 N {100 gf} 3 ...
Page 4
... A 3.5R +0.13 3.1 dia. hole −0.03 8.1 10.3±0.1 5.4 15.9 +0.13 3.1 −0.03 3.4±0.15 dia. 22.2±0.1 2.8 1 27.8 (10) D2RV-L13 D2RV 4.3 3.1 10.3 D2RV-LG 0.49 N {50 gf} 4.3 3.1 10.3 D2RV-L13G 0.49 N {50 gf} ...
Page 5
... PT A 34.0±0.8 +0.13 8.1 3.1 −0.03 dia. hole OP 10.3±0.1 5.4 2.8 +0.13 3.1 −0.03 3.4±0.15 dia. 22.2±0.1 2.8 1 27.8 (10) D2RV-L2 5.15 10.3 D2RV-L22G 0.98 N {100 gf} 5.15 15.9 10.3 D2RV-L2G 0.49 N {50 gf} D2RV 5 ...
Page 6
... H. This intersection indicates the value of 0.14 µF. This is the capacitance the constant C must satisfy. Constants for spark killer 4 10 1.1 0.4 1 0.004 0.01 400 PF 0.001 0 0.1 0.2 0.3 100 2,000 EC = 100 460 260 115 0.4 0.5 Load current I (A) D2RV ...
Page 7
... Switch. Tighten the screws to a torque of 0.39 N· kgf·cm}. When installing two or more Switches side by side, provide at least 8 mm between the adjacent Switches. If this is impossible, attach the optional magnetic baffle D2RV-@-I to the Switches. Actuator (Sold Separately) ■ Various Actuators are available as shown on D3V/V/VX/D2MV/ D2RV Common Accessories ...