E2C-JC4CH Omron, E2C-JC4CH Datasheet

DC AMP For M8 E2C-H HiTemp PRX

E2C-JC4CH

Manufacturer Part Number
E2C-JC4CH
Description
DC AMP For M8 E2C-H HiTemp PRX
Manufacturer
Omron
Series
E2Cr
Datasheet

Specifications of E2C-JC4CH

Amplifier Type
Standard
Voltage - Supply
12 V ~ 24 V
Output Type
NPN
Current - Supply
45mA
Mounting Type
Bracket Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E2CJC4CH
E2C-H
Proximity Sensor with Separate Amp
Resists Ambient Temperatures up to
200 C (392 F)
Ordering Information
Note: Sensors with 5 m cables are available on special request.
Application Example
Sensing head
M8
M12
M18
Heat-Resistant Inductive Prox. & Sep. Amp
A wide operating temperature range of
-10 to 200 C (14 to 392 F)
Ideal for checking the closing of mold
halves on injection molding machines or
for position sensing in high temperature
chambers or ovens
The compact, 14-mm wide amplifier can
be mounted to DIN track in normal
temperature environments
Adjustable sensing distance (remote)
Normally open/normally closed operation
switch-selectable
DETECTING POSITION OF MOLD HALVES
Shielded
Sensing distance
1.5 mm
2 mm
5 mm
2
Sensor part number
E2C-X1R5AH
E2C-X2AH
E2C-X5AH
Amplifier part number
E2C-JC4CH
E2C-JC4DH
E2C-JC4EH
E2C-H
E2C-H

Related parts for E2C-JC4CH

E2C-JC4CH Summary of contents

Page 1

... Ordering Information Sensing head M8 Shielded M12 M18 Note: Sensors with 5 m cables are available on special request. Application Example DETECTING POSITION OF MOLD HALVES Sensing distance Sensor part number 1.5 mm E2C-X1R5AH 2 mm E2C-X2AH 5 mm E2C-X5AH 2 E2C-H E2C-H Amplifier part number E2C-JC4CH E2C-JC4DH E2C-JC4EH ...

Page 2

... IP60 — — - 200 C ( 392 Hz, 1.5 mm (0.06 in) double amplitude for 2 hours each and Z directions 50 G E2C-JC4CH E2C-JC4DH VDC 45 mA max. Adjustable with 4-turn potentiometer between 20% and 100% of the rated sensing distance NPN open collector, 100 mA max. load selectable Operation indicator (red LED) ...

Page 3

... Note: IEC colors are shown in parentheses. TIMING CHART NO Operation mode NC selector ON Sensing object OFF ON Output transistor OFF ON Sensing indicator OFF (red LED) CONNECTION Sensor Shield Conductor brown (red) black (white) blue (black) Note: JIS colors are shown in parentheses VDC NPN open collector output E2C-H ...

Page 4

... E2C-H Engineering Data OPERATING RANGE (TYPICAL) E2C-X1R5AH + E2C-JC4CH SENSING DISTANCE VS. SENSING OBJECT (TYPICAL) E2C-X1R5AH + E2C-JC4CH Length of sensed object d (mm) E2C-X2AH + E2C-JC4DH E2C-X2AH + E2C-JC4DH Length of sensed object d (mm) 5 E2C-H E2C-X5AH + E2C-JC4EH E2C-X5AH + E2C-JC4EH Length of sensed object d (mm) ...

Page 5

... E2C-H Nomenclature Cover mounting screw Sensing distance adjuster Cable length compensation selector Dimensions Unit: mm (inch) E2C-X1R5AH E2C-X2AH E2C-X5AH Sensing indicator Operation mode selector 6 E2C-H ...

Page 6

... Note: The above torque values apply when you use a toothed washer with the nut that you tighten. Effects of Surrounding Metal When mounting the E2C-H within a metal panel, ensure that the clearances given in the following table are maintained. Failure to maintain these distances may cause deterioration in the performance of the sensor ...

Page 7

... Rear Front DIN-track or mounting bracket Removal You can remove the E2C-H by pulling the yellow grip rail on the lower part of the rear panel with a flat-blade screwdriver. Miscellaneous Do not expose the sensor to steam or install it in places where water may be sprayed because the sensor is not water resistive. ...

Related keywords