Specifications of G2R-1-E-T130 DC12

Relay Type
General Purpose
Contact Form
SPDT (1 Form C)
Contact Rating (current)
16A
Switching Voltage
380VAC, 125VDC - Max
Coil Type
Standard
Coil Current
43.6mA
Coil Voltage
12VDC
Turn On Voltage (max)
8.4 VDC
Turn Off Voltage (min)
1.8 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
16A @ 250VAC
Control On Voltage (max)
8.4 VDC
Control Off Voltage (min)
1.8 VDC
Contact Rating
10 A
Contact Termination
Quick Connect
Mounting Style
Plug-In
Power Consumption
530 mW
Contact Material
Silver Alloy
Coil Resistance
275 Ohms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G2R-1-E-T130DC12
G2R1ET130DC12
Latching dual coil type - Set coil
Latching dual coil type - Reset coil
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%.
■ Characteristics
Note: Data shown are of initial value.
194
3
5
6
12
24
3
5
6
12
24
Item
Contact resistance
Operate (set) time
Release (reset) time
Bounce time
Operating frequency
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Humidity
Service life
Weight
Rated voltage
Rated voltage
(VDC)
(VDC)
2. The operating characteristics are measured at a coil temperature of 23°C (73°F).
Power PCB Relay
227
167
138
70.60
34.60
200
119
100
50
25
Rated current
Rated current
(mA)
(mA)
Operate
Release
Mechanical
Electrical
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Mechanical
Electrical
10.80
30
43.50
170
694
15
42
60
240
960
resistance
resistance
G2R
Coil
Coil
(Ω)
(Ω)
0.026
0.073
0.104
0.42
1.74
0.001
0.003
0.005
0.018
0.079
Armature
Armature
Non-latching
100 mΩ
15 ms. max.
AC: 10 ms max.; DC: 5 ms max.
---
---
18,000 operations/hour
1,800 operations/hour (under rated load)
1,000 MΩ min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute across contacts of same pole
3,000 VAC, 50/60 Hz for 1 minute between contact sets, 2-pole non-latching
1,000 VAC, 50/60 Hz for 1 minute between set and reset coils of dual coil latching
10 to 55 Hz; 1.50 mm (0.06) double amplitude
10 to 55 Hz; 1.50 mm (0.06) double amplitude
1,000 m/s
200 m/s
100 m/s
-40 to 70°C (-40 to 158°F)
5% to 85% RH
10,000,000 operations min.
DC: 20,000,000 operations min.
(at 18,000 operations/hour)
100,000 operations min. (at 1,800 operations /hr) at rated load. See “Characteristics Data”
Approx. 17 g (0.60 oz.)
OFF
OFF
Coil inductance
Coil inductance
(ref. value) (H)
(ref. value) (H)
2
2
(approx. 20 G) when energized
(approx. 10 G) when de-energized
2
(approx. 100G)
0.052
0.146
0.208
0.83
3.43
0.002
0.006
0.009
0.036
0.148
Armature
Armature
ON
ON
70% max.
70% max.
Pick-up
voltage
Pick-up
voltage
% of rated voltage
% of rated voltage
70% max.
70% max.
Latching
20 ms max.
20 ms max.
Mean value approx. 3 ms
Mean value approx. 8 ms
500 m/s
200 m/s
100 m/s
10,000,000 operations min.
(at 18,000 operations/hour)
Approx. 17 g.
(Approx 20g for quick-connect type)
Dropout
Dropout
voltage
voltage
2
2
2
(approx. 50 G) at set (1-pole)
(approx 20G) at set (2-pole)
(approx. 10 G) at reset
110% max.
at 70°C
(158°F)
110% max.
at 70°C
(158°F)
Maximum
Maximum
voltage
voltage
Approx. 850
Approx. 600
consumption
consumption
Power
Power
(mW)
(mW)