G5AK-234P-DC24 Omron, G5AK-234P-DC24 Datasheet - Page 3

LOW SIGNAL RELAY

G5AK-234P-DC24

Manufacturer Part Number
G5AK-234P-DC24
Description
LOW SIGNAL RELAY
Manufacturer
Omron
Series
G5Ar
Datasheet

Specifications of G5AK-234P-DC24

Relay Type
General Purpose
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
1A @ 30VDC
Coil Type
Latching, Dual Coil
Coil Current
8.3mA
Coil Voltage
24VDC
Control On Voltage (max)
19.2 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Form
2 Form C
Power Consumption
200 mW
Maximum Switching Current
1 A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G5AK234PDC24

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G5AK-234P-DC24V
Manufacturer:
OMRON
Quantity:
12 000
■ Characteristics
Note: 1. Data shown are of initial value.
■ Characteristic Data
Contact resistance (See note 2)
Operate (set) time
Release (reset) time
Operating frequency
(max.)
Insulation resistance (See note 3)
Dielectric strength
Impulse Withstand Voltage (See notes 4 & 5) 1,500 V (10 x 160 μs) between contacts of the same polarity (conforms to FCC Part 68)
Vibration
Shock
Ambient temperature
Humidity
Service life
Weight
Maximum Switching Capacity
2. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method
3. The insulation resistance was measured with a 250-VDC megohmmeter applied to the same parts as those used for checking
4. Models with FC suffix: 1,200 VAC, 50/60 Hz for 1 min, impulse withstand voltage of 1,500 V (10 x 160 μs)
5. Models with FC suffix: 750 VAC, 50/60 Hz for 1 min, impulse withstand voltage of 1,500 V (10 x 160 μs)
DC inductive
load (L/R = 7
ms)
the dielectric strength (except between the set and reset coil).
Rated operating voltage (V)
AC inductive load
(cosf = 0.4)
Type
Standard
Mechanical durability
Mechanical
Mechanical
Electrical
Set and reset coils
Mechanical durability
Malfunction durability 10 to 55 Hz; 1.50 mm (0.06 in) double amplitude
Malfunction durability 300 m/s
Electrical
DC resistive
load
AC resistive
load
Electrical Service Life
10,000
5,000
1,000
50 mΩ max.
5 ms. max. (mean value approx 2.4 ms)
5 ms. max. (mean value approx. 1.1 ms)
36,000 operations/hour
18,000 operations/hour (under rated load)
1,000 mΩ min. (at 250 VDC)
1,000 VAC, 50/60 Hz for 1 minute between coil and contacts (See note 4)
1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles (See note 4)
500 VAC, 50/60 Hz for 1 minute between contacts of same pole (See note 5)
--
10 to 55 Hz; 1.50 mm (0.06 in) double amplitude
1,000 m/s
-40 to 70°C (-40 to 158°F) with no icing
5% to 85% RH
50 million operations min.
at 36,000 operations/hour
100,000 operations min. (at 1,800 operations/hr) See “Characteristic Data”
Approx. 3 g (0.11 oz)
500
100
50
30-VAC inductive
load (cosf = 0.4)
Rated operating current (A)
2
DISCONTINUED
(approx. 30 G
2
30-VDC inductiveload
(L/R = 7 ms)
(approx. 100 G)
Non-latching
30-VDC
resistive
load
30-VAC
resistive
load
Note: The maximum coil voltage refers to
Ambient Temperature vs.
Maximum Coil Voltage
5 ms. max. (mean value approx. 2.0 ms)
5 ms. max. (mean value approx. 1.8 ms)
100 VAC, 50/60 Hz for 1 minute
50 million operations min.
at 36,000 operations/hour
Low Signal Relay
the maximum value in a varying
range of operating power voltage,
not a continuous voltage.
280 mW
Ambient temperature (°C)
Latching
200 mW
G5A
33

Related parts for G5AK-234P-DC24