G5RL-1A-E AC115/120 Omron, G5RL-1A-E AC115/120 Datasheet - Page 4

Power PCB Relay

G5RL-1A-E AC115/120

Manufacturer Part Number
G5RL-1A-E AC115/120
Description
Power PCB Relay
Manufacturer
Omron
Datasheet

Specifications of G5RL-1A-E AC115/120

Contact Form
SPST - NO
Coil Voltage
115 VAC, 120 VAC
Contact Rating
16 A
Coil Termination
Pin
Contact Termination
Solder Pin
Mounting Style
PCB
Power Consumption
0.75 VA
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
High-Inrush Models: G5RL-1(A)-E-HR
■ Specifications
Coil Ratings
Note: The rated current and resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Contact Ratings
Characteristics
Note: 1. Values in the above table are initial values.
216
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Contact form
Contact material
Rated load (resistive)
Rated carry current
Max. switching voltage
Max. switching current
Max. switching capacity
Min. permissible load
(reference value)
Contact resistance
Operate time
Release time
Insulation resistance
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Life expectancy
Ambient temperature
Ambient humidity
Weight
2. The contact resistance is measured with 1 A applied at 5 VDC using voltage drop method.
3. The insulation resistance is measured between coil and contacts and between contacts of the same polarity at 500 VDC.
4. The resistive load ratings for NO contact apply when there is no load on NC contact.
Rated voltage
PCB Relay
G5RL
80.0 mA
62.5 Ω
70% max. rated voltage
10% min. rated voltage
130% of rated voltage
Approx. 400 mW
SPST-NO
Ag alloy (Cd free)
16 A at 250 VAC
16 A at 24 VDC
16 A
250 VAC, 24 VDC
16 A
4,000 VA, 384 W
100 mA at 5 VDC: P level:
100 mΩ max.
15 ms max.
5 ms max.
1,000 MΩ min. (at 500 VDC)
6,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
10 kV between coil and contacts (1.2 × 50 μs)
Destruction: 10 to 55 Hz, 1.5-mm double amplitude
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s
Malfunction: 100 m/s
Mechanical: 10,000,000 operations min. (at 18,000 operations/hr)
Electrical:
Operating: –40°C to 85°C (with no icing or condensation)
Operating: 5% to 85%
Approx. 10 g
5 VDC
100,000 operations min. (at 1,800 operations/hr)
(Resistive load, 12A, 250 VAC/24 VDC, NO contact)
50,000 operations min. (at 1,800 operations/hr)
(Resistive load, 16 A, 250 VAC/24 VDC, NO contact)
(Resistive load, 5 A, 250 VAC/24 VDC, NC contact)
2
(approx. 10G)
2
(approx. 100G)
λ
33.3 mA
360 Ω
60
= 0.1 x 10
12 VDC
–6
operations
16.7 mA
1,440 Ω
SPDT
16 A at 250 VAC, 24 VDC (NO)
when there is no load on (NC)
5 A at 250 VAC, 24 VDC (SPDT)
16 A (NO), 5 A (NC)
16 A (NO), 5 A (NC)
4,000 VA, 384 W (NO)
when there is no load on (NC)
1,250 VA, 120 W (SPDT)
24 VDC
8.96 mA
5,358 Ω
Approx. 430 mW
48 VDC

Related parts for G5RL-1A-E AC115/120