G6CU-2114P-US DC3 Omron, G6CU-2114P-US DC3 Datasheet - Page 3

POWER PCB RELAY

G6CU-2114P-US DC3

Manufacturer Part Number
G6CU-2114P-US DC3
Description
POWER PCB RELAY
Manufacturer
Omron
Series
G6Cr
Datasheet

Specifications of G6CU-2114P-US DC3

Relay Type
General Purpose
Contact Form
DPST-NO/NC (1 Form A and B)
Contact Rating (current)
8A
Switching Voltage
250VAC, 125VDC - Max
Coil Type
Latching, Single Coil
Coil Current
66.7mA
Coil Voltage
3VDC
Turn On Voltage (max)
2.1 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
DPST-NO/NC (1 Form A and B)
Contact Rating @ Voltage
8A @ 250VAC
Control On Voltage (max)
2.1 VDC
Power Consumption
200 mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
 Details
Other names
G6CU-2114P-USDC3
G6CU2114PUSDC3
Single Coil Latching Type
Dual Coil Latching Type
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
■ Characteristics
3
5
6
12
24
3
5
6
12
24
Contact resistance
Operate (set) time
Release (reset) time
Bounce time
Min. set/reset signal width
Max. switching
frequency
Insulation resistance
Dielectric strength
Surge withstand voltage
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Service Life
Weight
voltage
voltage
Rated
(VDC)
Rated
(VDC)
2. Operating characteristics are measured at a coil temperature of 23°C.
3. The minimum pulse width of the set and reset voltage is 20 ms.
93.50
56
46.70
23.30
11.70
67
40
33.30
16.70
8.30
current
Rated
(mA)
current
Rated
(mA)
resistance
32.10
89.30
129
514
2,056
45
125
180
720
2,880
Mechanical
Electrical
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Mechanical:
Electrical:
Coil
resistance
(Ω)
Coil
(Ω)
0.03
0.07
0.10
0.37
1.56
Armature
OFF
0.09
0.25
0.36
1.75
5.83
Armature
Set Coil
OFF
Coil inductance
(ref. value) (H)
0.02
0.06
0.08
0.32
1.18
Armature
Coil inductance
ON
(ref. value) (H)
30 mΩ max.
10 ms max. (mean value: approx. 5 ms)
10 ms max. (mean value: approx. 2 ms; latching types: mean value: approx. 5 ms)
5 ms max. (Approx. 3 ms typical)
Latching type: 20 ms (at 23°C)
18,000 operations/hr
1,800 operations/hr (under rated load)
1,000 MΩ min. (at 500 VDC, at 250 VDC between set coil and reset coil)
2,000 VAC, 50/60 Hz for 1 min between coil and contacts
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
250 VAC, 50/60 Hz for 1 min between set and reset coils (double winding latching type)
6.000 V (1.2 x 50 μs) between coil and contacts (latching types: 4,500 V, 1.2 x 50 μs)
10 to 55 Hz, 1.5-mm double amplitude
10 to 55 Hz, 1.5-mm double amplitude
1,000 m/s
100 m/s
Operating: −25°C to 70°C (with no icing)
Operating: 5% to 85%
50,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr) See “Characteristic Data”
Approx. 5.6 g
0.06
0.20
0.24
1.17
3.84
Armature
ON
0.03
0.08
0.12
0.47
1.46
Armature
2
(Approx. 10G)
OFF
2
(Appox. 100G)
Reset Coil
70% max.
pick-up voltage
0.02
0.07
0.10
0.38
1.13
Armature
Set
ON
% of rated voltage
70% max.
70% min.
pick-up
voltage
pick-up voltage
Set
Reset
% of rated voltage
Power PCB Relay
70% max.
pick-up
voltage
Reset
160% max.
at 23°C
Maximum
voltage
130% max.
at 23°C)
Maximum
voltage
G6C
Approx. 200
consumption
consumption
Approx. 280
Power
(mW)
Power
(mW)
159

Related parts for G6CU-2114P-US DC3