XS2W-D421-A81-A Omron, XS2W-D421-A81-A Datasheet - Page 28

no-image

XS2W-D421-A81-A

Manufacturer Part Number
XS2W-D421-A81-A
Description
Connector
Manufacturer
Omron
Series
XS2r
Datasheets

Specifications of XS2W-D421-A81-A

Connector Type
Circular 04 pos Female to Male
Length
0.98' (300mm)
Cable Type
Round
Color
Gray
Shielding
Unshielded
Usage
Industrial Environments - IP67
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
XS2WD421A81A
Insertion
Cable End Processing
Screw-on Connectors
Five-core Connectors
Four-core Connectors
Tentatively insert the pins to the pin block holes so that the
key on the pin block will coincide with the key groove on the
pin clamp. Then insert the cable along with the pin clamp.
Loosen the screws on pins 1 to 4 and insert the cores
according to the pin numbers.
Use the special Screwdriver (XW4Z-00B) and tighten the
screws securely so that the cores do not pull out (tightening
torque: 0.15 to 0.2 N·m).
Strip the cable sheath for a total of 15 mm and strip the core
covering for 8 mm for the core to connect to pin 5.
Connect the core to pin 5 (in the center) first.
Insert the core from the side of the hold with the tab and
tighten the screw securely (tightening torque: 0.15 to
0.2 N·m), and then cut off the excess wire with wire cutters.
Pin Block
Screw
8
Screwdriver
Special
7
Key
8
12
±0.5
12
Conductors for
pins 1 to 4
Conductors for
pin 5
Tab
XS2C use XS2G use
Pin Clamp
6
Key groove Key groove
±0.5
Screw
Screwdriver
Special
Connecting Shielded Cables to Five-core Connectors
*
(4) Inserting Pin Block
When tightening the screws, use the dedicated XW4Z-00B
Screwdriver that matches with the screw-slot dimensions.
Bend the cable as shown below, attached the enclosed
insulation cap, and then strip the other cores.
Connect the cores to pins 1 to 4.
Place the insulation tube on the drain line of the shield and
connect to the terminal.
Tighten the screw and then check visually to see if there is
insulation between the cores.
Connect the cores to pins 1 to 4.
Mount the cover to the pin block so that the triangle mark on
the pin block will coincide with the triangle mark on the
cover.
If the cover is used for an L-shaped model, the relationship
between the position of the polarity key on the engaged side
and cable connection direction will be determined by the
direction in which the positioning key is inserted into the
cover, which can be rotated by 90 .
Fully insert the positioning key until the positioning key is
hidden by the casing.
Pin Block
(Soldering Model)
(Crimping Model)
Polarity key
Lock spring
Positioning key
(triangle mark)
XW4Z-00B
Screwdriver
Drain line
O-ring
Insulation tube
Insulation cap
Cover
(Straight Model)
(Angled Model)
Triangle mark
XS2
28

Related parts for XS2W-D421-A81-A