88974052 Crouzet USA, 88974052 Datasheet - Page 6

no-image

88974052

Manufacturer Part Number
88974052
Description
M3 CUSTOM CD20ST
Manufacturer
Crouzet USA
Datasheet

Specifications of 88974052

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
www.millenium3.crouzet.com
Potentiometer control
Inputs used as digital inputs
Input voltage
Input current
Input impedance
Logic 1 voltage threshold
Making current at logic state 1
Logic 0 voltage threshold
Release current at logic state 0
Response time
Maximum counting frequency
Sensor type
Conforming to IEC/EN 61131-2
Input type
Isolation between power supply and inputs
Isolation between inputs
Protection against polarity inversions
Status indicator
Max. breaking voltage
Breaking current
Max. Output Common Current
Electrical durability for 500 000 operating cycles
Minimum switching capacity
Minimum load
Maximum rate
Mechanical life
Voltage for withstanding shocks
Response time
Built-in protections
Status indicator
PWM solid state output*
* Only available with "FBD" programming language
Breaking voltage
Nominal voltage
Nominal current
Max. breaking current
Voltage drop
Response time
Built-in protections
Min. load
Maximum incandescent load
Galvanic isolation
PWM frequency
PWM cyclic ratio
PWM accuracy at 120 Hz
PWM accuracy at 500 Hz
Status indicator
Characteristics of relay outputs common to the entire range
Digital / PWM solid state output
:For adapted products, see page page 64-65
(*) In the absence of a volt-free contact between the output of the logic controller and the load
12-24 V
(88970814 & 88970840)
2.2 kΩ/0.5 W (recommended)
10 kΩ max.
12 V
0.7 mA @ 10.44 V
0.9 mA @ 12.0 V
1.0 mA @ 14.4V
14 kΩ
≥ 7 V
≥ 0.5 mA
≤ 3 V
≤ 0.2 mA
1
In accordance with cycle time (Tc) and
input response time (Tr) : 1/ ( (2 x Tc) + Tr)
Contact or 3-wire PNP
Type 1
Resistive
None
None
Yes
On LCD screen for CD and XD
5
24
CB-CD-XD10-XB10-XR06-XR10: 8 A
XD26-XB26: 8 x 8 A relays, 2 x 5 A relays
XE10: 4 x 5 A relays
XR14: 4 x 8 A relays, 2 x 5 A relays
12A for O8,O9,OA
Usage category DC-12: 24 V, 1.5 A
Usage category DC-13: 24 V (L/R = 10 ms), 0.6 A
Usage category AC-12: 230 V, 1.5 A
Usage category AC-15: 230 V, 0.9 A
10 mA (at minimum voltage of 12 V)
12 V, 10 mA
Off load: 10 Hz
At operating current: 0.1 Hz
10.000.000 operations (cycles)
In accordance with IEC/EN 60947-1 and IEC/EN 60664-1: 4 kV
Make 10 ms
Release 5 ms
Against short-circuits: None
Against overvoltages and overloads: None
On LCD screen for CD and XD
CB12: O4
XD26: O4
10.4
12-24 V
0.5 A
0.625 A
≤ 2 V for I = 0.5 A (at state 1)
Make ≤ 1 ms
Release ≤ 1 ms
Against overloads and short-circuits: Yes
Against overvoltages (*) : Yes
Against inversions of power supply: Yes
1 mA
0.2 A / 12 V
0.1 A / 24 V
No
14.11 Hz - 56.45 Hz - 112.90 Hz - 225.80
Hz - 451.59 Hz - 1806.37 Hz
0
for XA)
< 5% (20%
< 10% (20%
On LCD screen for XD
2 cycle times
30 V
100% (256 steps for CD, XD and 1024
250 V
30 V
(-13% / +20%)
O7
80%) load at 10 mA
80%) load at 10 mA
2.2 kΩ/0.5 W (recommended)
10 kΩ max.
24 V
1.6 mA @ 19.2 V
2.0 mA @ 24.0 V
2.5 mA @ 30.0 V
12 kΩ
≥ 15 V
≥ 1.2 mA
≤ 5 V
≤ 0.5 mA
1
In accordance with cycle time (Tc) and
input response time (Tr) : 1/ ( (2 x Tc) + Tr)
Contact or 3-wire PNP
Type 1
Resistive
None
None
Yes
On LCD screen for CD and XD
24 V
(88970..2)
CD12-XD10-XB10: O4
CD20-XD26-XB26: O4
19.2
24 V
0.5 A
0.625 A
≤ 2 V for I = 0.5 A (at state 1)
Make ≤ 1 ms
Release ≤ 1 ms
Against overloads and short-circuits: Yes
Against overvoltages (*) : Yes
Against inversions of power supply: Yes
1 mA
0.1 A / 24 V
No
14.11 Hz - 56.45 Hz - 112.90 Hz - 225.80
Hz - 451.59 Hz - 1806.37 Hz
0
for XA)
< 5% (20%
< 10% (20%
On LCD screen for CD and XD
2 cycle times
100% (256 steps for CD, XD and 1024
30 V
(-20% / +25%)
80%) load at 10 mA
80%) load at 10 mA
O7
25

Related parts for 88974052