AA2-B0-34-650-5G1-C Carling Technologies, AA2-B0-34-650-5G1-C Datasheet

CIRCUIT BREAKER

AA2-B0-34-650-5G1-C

Manufacturer Part Number
AA2-B0-34-650-5G1-C
Description
CIRCUIT BREAKER
Manufacturer
Carling Technologies
Datasheet

Specifications of AA2-B0-34-650-5G1-C

Product Type
Circuit Breakers
Current Rating
50 Amps
Voltage Rating
277 VoltsAC, 80 VoltsDC
Number Of Poles
2 Poles
Mounting Style
Screw
Actuator Type
Handle
Termination Style
Screw
Circuit Function
Series Trip (Current)
Product
Hydraulic Magnetic Circuit Breakers
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
34
A-Series – General Specifications
Agency Certifications
UL Recognized
UL Standard 1077
UL Standard 508
UL Standard 1500
Component Recognition Program
as Protectors Supplementary
(Guide CCN/QVNU2, File E75596)
Switches, Industrial Control
(Guide CCN/NRNT2, File E148683)
Protectors, Supplementary for
Marine Electrical & Fuel Systems
(Guide PEQZ2, File E75596)
Ignition Protection
UL Listed
UL Standard 489A
CSA Accepted
TUV Certified
VDE Certified
Compact size and well known for its proven reliability, the A-Series
utilizes the hydraulic magnetic principle which provides precise
operation and performance even when exposed to extremely hot
and/or cold application environments. When aesthetics demand a
clean contemporary and functional design, the visi-rocker two-color
actuator can be specified. A rockerguard and push-to-reset bezel
help prevent inadvertent actuation. A specially constructed version
is now available for applications requiring CE markings. The
A-Series is used in many telecommunications and marine applica-
tions. In addition, these breakers meet CSA Standard 22.2 No.
100 for the Generator & Welder markets.
1-6 poles (handle), 1-3 poles (rocker). 0.02 - 50 amps, up to 277
VAC or 80 VDC, with a choice of time delays, terminals and actua-
tor colors.
Communications Equipment (Guide
CCN/DITT, File E189195)
Component Supplementary
Protector under Class 3215 30,
File 047848 0 000 CSA
Standard C22.2 No. 235
EN60934, under License No.
R72040875
EN60934, VDE 0642 under File No.
10537
www.carlingtech.com

Related parts for AA2-B0-34-650-5G1-C

AA2-B0-34-650-5G1-C Summary of contents

Page 1

... A-Series – General Specifications Agency Certifications UL Recognized UL Standard 1077 Component Recognition Program as Protectors Supplementary (Guide CCN/QVNU2, File E75596) UL Standard 508 Switches, Industrial Control (Guide CCN/NRNT2, File E148683) UL Standard 1500 Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection 34 ...

Page 2

Electrical Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector. Notes for Table A: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum ...

Page 3

A-Series – General Specifications Electrical Table B: Lists UL Recognized, CSA Accepted, VDE & TUV Certified configurations & performance capabilities as a Component Supplementary Protector. Notes for Table B: 1 General Purpose Ratings for UL/CSA Only. 2 Requires branch circuit ...

Page 4

Electrical Maximum Voltage 277VAC 50/60 Hz, 80VDC Current Ratings Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 35.0, 40.0, 50.0. Other ratings available - consult ordering scheme. Standard Voltage Coils DC-6V, 12V; ...

Page 5

A-Series Handle UL Recognized – Ordering Scheme – Series Poles Actuator Circuit 1 SERIES A 2 ACTUATOR 1 A Handle, one per pole B Handle, one per multipole unit S Mid-Trip ...

Page 6

– Series Poles Aux/Alarm Actuator Circuit Switch 1 SERIES A 2 ACTUATOR 1 A Handle, one per pole S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole ...

Page 7

A-Series Handle WORLD – Ordering Scheme – Series Poles Actuator Circuit 1 SERIES A 2 ACTUATOR 1 A Handle, one per pole S Mid-Trip Handle, one per pole T Mid-Trip Handle, ...

Page 8

Poles Series Actuator Circuit 1 SERIES A 2 ACTUATOR 1 M Sealed Toggle, one per unit 3 POLES 1 One 2 Two 3 Three 4 CIRCUIT ...

Page 9

A-Series Rocker UL Recognized – Ordering Scheme – Poles Series Actuator Circuit 1 SERIES A 2 ACTUATOR 1 Two Color Visi-Rocker Push-To-Reset , Single color C Indicate ON, vertical legend R ...

Page 10

Poles Aux/Alarm Series Actuator Circuit Switch 1 SERIES A 2 ACTUATOR 1 Two Color Visi-Rocker Push-To-Reset, Visi-Rocker C Indicate ON, vertical legend N D Indicate ON, horizontal legend F ...

Page 11

A-Series Flat Rocker UL Recognized – Ordering Scheme – Poles Series Actuator Circuit 1 SERIES A 2 ACTUATOR 1 Two Color Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal ...

Page 12

Poles Aux/Alarm Series Actuator Circuit Switch 1 SERIES A 2 ACTUATOR 1 Two Color Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single color 3 Vertical ...

Page 13

A-Series Handle – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Alarm Switch available with .110 x .020 Q.C. & Solder Lug Terminals Only. 46 www.carlingtech.com ...

Page 14

Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Alarm Switch available with .110 x .020 QC & solder lug terminals only. www.carlingtech.com A-Series Handle – Circuit & Terminal Diagrams 47 ...

Page 15

A-Series Handle – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ± 0.20 [.51] unless otherwise specified. 3 For agency code P = .150 [3.81]. 48 www.carlingtech.com ...

Page 16

Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com A-Series Handle – Front Panel Snap-In Mounting Style 5 49 ...

Page 17

A-Series Handle – Front Panel Snap-In Mounting Style 7 Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance ±.020 [.51] unless otherwise specified. 50 www.carlingtech.com ...

Page 18

Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com A-Series Sealed Toggle – Form & Fit Drawings 51 ...

Page 19

A-Series Rocker – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuit. 4. Circuits shown for >30 amps / VDE. 52 www.carlingtech.com ...

Page 20

Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate OFF is opposite of indicate ON. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 All dimensions ...

Page 21

A-Series Rocker Snap-In Bracket – Form & Fit Drawings Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. Orientation on indicate ...

Page 22

Notes: 1 All dimensions are in inches [millimeters]. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 Tolerance ± 0.20 [.51] unless otherwise specified. www.carlingtech.com A-Series Flat Rocker – Form & Fit Drawings 55 ...

Page 23

A-Series PC Terminal Diagrams Notes: 1 Drawing illustrates A-Series with VDE certification. 2 All dimensions are in inches [millimeters]. 3 Tolerance ± 0.20 [.51] unless otherwise specified. 56 www.carlingtech.com ...