HE2B-M200 IDEC, HE2B-M200 Datasheet

no-image

HE2B-M200

Manufacturer Part Number
HE2B-M200
Description
HE2B-M200 W/o Rubber Cover Enabling Sw (includes 2 Nuts)
Manufacturer
IDEC
Datasheet
Enabling Switches
HE2B Key features include:
Specifi cations
Conforming to Standards
Application Standards
Operating Temperature
Operating Humidity
Storage Temperature
Pollution Degree
Contact Resistance
Insulation Resistance
Impulse Withstand Voltage
Operating Frequency
Mechanical Life
Electrical Life
Shock
Resistance
Vibration
Resistance
Terminal
Recommend Wire Size
Solder Heat Resistance
Terminal Pulling Strength
Recommended Screw Torque
Degree of Protection
Conditional Short-Circuit Current
Recommended Short Circuit Protection 250V/10A fast blow fuse (IEC 60127-1)
Weight
Circuit Opening Force
Actuating Force (Operating)
3 position funtionality (OFF – ON –OFF) as required for manual robotic control
Ideally suited for use as enabling (aka “deadman”) switch on teach pendants
Provides a high level of safety based on human behavioral studies that determine
personnel may squeeze OR let go when presented with a panic situation
Snap acting contacts from Off‡On (1‡ 2)
Positive action contacts from On‡Off (2‡ 3) ensure no contact welding (per
EN60947-5-1 / IEC60947-5-1)
Contacts will not re-close when released from Off‡On (3‡1) (per IEC60204-1;
9.2.5.8)
Multiple contacts for enhanced reliability
Monitoring contacts in addition to main load contacts
Available with or without rubber cover (cover provides IP65 watertight seal)
Operating Extremes
Damage Limits
Operating Extremes
Damage Limits
HE2B Series Redundant (Double) Basic Enabling Switch
IEC60947-5-1, EN60947-5-1, JIS C8201-5-1, UL508, CSA C22.2 No 14
ISO12100/EN292, IEC60204-1/EN60204-1, ISO11161/prEN11161, ISO10218/
EN775, ANSI/RIA R15.06
–25 to +60˚C (no freezing)
45 to 85% RH (no condensation)
–40 to +80˚C (no freezing)
2 (inside of panel/contact side)
3 (outside of panel/operating side)
50mΩ maximum
Between live and dead metal parts: 100MΩ maximum
Between positive and negative live parts: 100MΩ minimum
2.5kV
1200 operations/hour
Position 1‡2: 1,000,000 operations minimum
Position 1‡2‡3‡1: 100,000 operations minimum
100,000 (at full rated load)
100m/s
1000m/s
5 to 55Hz, amplitude 0.5mm minimum
16.7Hz, amplitude 1.5mm minimum
0.110” quick connect / solder terminal
0.5mm
260°C / 3 seconds maximum
20N minimum
0.5 to 0.8Nm
with rubber cover: IP65,
without rubber cover: IP40 (IEC 60529),
50A (250V)
Approx. 26g (without cover), 30g (with cover)
60N minimum (button return monitor & button push monitor)
500N minimum
2
2
maximum / 1 line (20AWG)
(10 G)
2
(100 G)
USA: 800-262-IDEC
Canada: 888-317-IDEC
Ordering Information
HE2B - M 2 0 0 P Y
3 Position
Switch
2: 2 contacts
(DPDT)
HE2B Series
Return Monitor
Switch
0: None
1: 1 contact
2: 2 contacts
Rubber Cover
Color
Rubber Cover
Push Monitor
Switch
None: without
Y: Yellow
B: Black
None: without
P: with cover
0: None
1: 1 contact
2: 2 contacts
cover
cover
407

Related parts for HE2B-M200

HE2B-M200 Summary of contents

Page 1

... Actuating Force (Operating) 500N minimum (10 G) (100 G) 2 maximum / 1 line (20AWG) USA: 800-262-IDEC Canada: 888-317-IDEC HE2B Series Ordering Information HE2B - Position Rubber Cover Switch Color 2: 2 contacts None: without (DPDT) cover Y: Yellow B: Black ...

Page 2

... Resistive Load (DC-12) 2A 0.4A Inductive Load (DC-13) 1A 0.22A 2 contacts (DPDT contacts contacts Printed Side HE2B-M211 www.idec.com Enabling Switches Part Number Return Monitor Switch 0 HE2B-M200 1 HE2B-M211 2 HE2B-M222 0 HE2B-M200PY 1 HE2B-M211PY 2 HE2B-M222PY 0 HE2B-M200PB 1 HE2B-M211PB 2 HE2B-M222PB 250V 0.5A 0.5A – – 1A 0.5A 0.2A 0.1A Printed Side HE2B-M222 ...

Page 3

... Approx. 30N Approx. 4N ±0.3 ±0.3 Travel (mm) 0 1.4 2.4 3.0 With Rubber Cover Part Number Material HE9Z-D2Y Silicon Rubber HE9Z-D2B USA: 800-262-IDEC Canada: 888-317-IDEC HE2B Series Position 3 ±0.3 ±0.5 ±0.5 ±0.5 3.6 4.2 6.0 Mounting Hole Layout ±0.2 70 ±0.2 78 Mounting Screws 409 ...

Page 4

... Connector & Grip Switch L3=6mm Connector Terminal Screw Do Not Remove HE1B/HE2B/HE3B • When installing the enabling switch ensure that it cannot be accidently activated. For example, a protrusion from a teaching pendant could cause the enabling switch to be activated by the weight of the teaching pendant. USA: 800-262-IDEC ...

Related keywords