A22E-M-02B Omron, A22E-M-02B Datasheet

no-image

A22E-M-02B

Manufacturer Part Number
A22E-M-02B
Description
Non-lighted,push-lock,turnrese
Manufacturer
Omron
Datasheet

Specifications of A22E-M-02B

Contact Configuration
DPST-NC
Switch Operation
Pushlock Turn Reset
Contact Voltage Ac Nom
440V
Contact Voltage Dc Nom
380V
Contact Current Max
10A
Actuator Style
Round
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Install in 22-dia. or 25-dia. Panel Cutout
• Direct opening mechanism to open the circuit when the contact
• Safety lock mechanism prevents operating errors.
• Easy mounting and removal of Switch Blocks using a lever.
• Mount three Switch Units in series to improve wiring efficiency
• Finger protection mechanism on Switch Unit provided as a
• Install using either round, or forked crimp terminals.
• Oil-resistant to IP65 (non-lighted models)/IP65 (lighted models)
Note: Be sure to read the precautions for all pushbutton switches in the
Features
Safety Lock Mechanism to Prevent Misuse
This Switch uses a finger protection
mechanism to prevent electrical shocks.
Moreover, it is provided with a mechanism
to prevent terminal screws from coming
off and also allows connection to either
round or forked crimp terminals.
welds
(with non-lighted Switch Units, three Units can be mounted for
multiple contacts).
standard feature.
Emergency Stop Switch
A22E
This Switch enables emergency stops only when the pushbutton is
pressed intentionally and firmly.
Even if an object or person touches the pushbutton by mistake, the
contact will not be released unless the pushbutton reaches the lock
position.
Finger protection
Pushbutton Switches Group Catalog (Cat. No. X018), as well as
the “Safety Precautions” on page 19.
Lock position
.
http://www.ia.omron.com/
Mechanism for
preventing
terminal screws
from coming off
(loosening the
screws do not
cause them to
come off)
Construction
(The above figures are
examples of the lighted model.)
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Color: Red
Non-lighted
Lighted
Light source
• LED Lamp
• Incandescent Lamp
Contact Ratings
10 A at 110 VAC (resistive load)
10 A at 24 VDC (resistive load)
Lighting Method
Non-lighted
Lighted (without Voltage Reduction
Unit)
Lighted (with Voltage Reduction Unit)
Lamp
Operation
Unit
Switch
1

Related parts for A22E-M-02B

A22E-M-02B Summary of contents

Page 1

... Emergency Stop Switch A22E Install in 22-dia. or 25-dia. Panel Cutout • Direct opening mechanism to open the circuit when the contact → welds . • Safety lock mechanism prevents operating errors. • Easy mounting and removal of Switch Blocks using a lever. • Mount three Switch Units in series to improve wiring efficiency (with non-lighted Switch Units, three Units can be mounted for multiple contacts) ...

Page 2

... VAC 200 VAC lit by directly applying 110 VAC/VDC (220 VAC/VDC) to the lamp terminal. LED incorporates the 24-VAC/VDC models. 2. Equipped with 24-VAC/DC LED. (c)Copyright OMRON Corporation 2007 All Rights Reserved. A22E 5. Configuration Code Configuration None Switch only Switch with Integrated B Control Box ...

Page 3

... SPST-NC A22E-S-01 SPST-NO/SPST-NC A22E-S-11 DPST-NC A22E-S-02 DPST-NC + SPST-NO A22E-S12 TPST-NC A22E-S-03 SPST-NC A22E-M-01 SPST-NO/SPST-NC A22E-M-11 DPST-NC A22E-M-02 DPST-NC + SPST-NO A22E-M-12 TPST-NC A22E-M-03 SPST-NC A22E-L-01 SPST-NO/SPST-NC A22E-L-11 DPST-NC A22E-L-02 SPST-NC A22E-SK-01 SPST-NO/SPST-NC A22E-SK-11 DPST-NC A22E-SK-02 SPST-NC A22E-MK-01 SPST-NO/SPST-NC A22E-MK-11 DPST-NC A22E-MK-02 (c)Copyright OMRON Corporation 2007 All Rights Reserved. ...

Page 4

... VDC 6 VAC 12 VAC/VDC 24 VAC/VDC 100 VAC 200 VAC 100 VAC 200 VAC 100 VAC 200 VAC Model A22E-M-01B A22E-M-11B A22E-M-02B (c)Copyright OMRON Corporation 2007 All Rights Reserved. A22E Push-lock turn- Color of cap reset system A22EL-M-6D-01 Red A22EL-M-6A-01 A22EL-M-12A-01 A22EL-M-24A-01 A22EL-M-6D-11 A22EL-M-6A-11 ...

Page 5

... Lighted (wituout Voltage Reduction Unit) Operation Unit Lamp Incandescent LED Switch (withtout Voltage Reduction Unit) (c)Copyright OMRON Corporation 2007 All Rights Reserved. A22E ● Lighted (with Voltage Reduction Unit) Operation Unit Lamp LED Switch (with Voltage Reduction Unit) 5 ...

Page 6

... A22E-S Push-lock, key-reset A22E-SK (push-lock, turn-reset) Lighted Sealing capability and size Push-lock, Turn-reset A22EL-M http://www.ia.omron.com/ IP65 oil-resistant models Small (30 dia.) Medium (40 dia.) A22E-MP A22E-M A22E-MK IP65 Medium (40 dia.) (c)Copyright OMRON Corporation 2007 All Rights Reserved. A22E Large (60 dia.) A22E-LP A22E-L --- 6 ...

Page 7

... A22-12 A22-24 A22-H1 Non-lighted Momentary A22-10M A22-01M A22-20M A22-02M Lighted (110 VAC) Momentary A22L-10M-T1 A22L-01M-T1 A22L-20M-T1 A22L-02M-T1 (c)Copyright OMRON Corporation 2007 All Rights Reserved. A22E Lighted Momentary A22L-10M A22L-01M A22L-11M A22L-20M A22L-02M Lighted (220 VAC) Momentary A22L-10M-T2 A22L-01M-T2 A22L-11M-T2 A22L-20M-T2 A22L-02M-T2 7 ...

Page 8

... A22K-K Rounded shape A22Z-3360 --- A22Z-3901 --- A22Z-3905 (c)Copyright OMRON Corporation 2007 All Rights Reserved. A22E Remarks Provided as standard. Order Switch Blocks only when adding or replacing them. Used when changing the lighting method. Provided as standard. Order Mounting Latches only when mounting Switch Blocks or Lamp Sockets that are purchased individually ...

Page 9

... SEMI-S2/SEMATECH Application Guide for SEMI-S2-compatibility. The SEMI-S2- compatible Shroud and legend plate for EMERGENCY OFF come as a set. Use with an A22E Emergency Stop Switch. SEMI-S2/SEMATECH Application Guide for SEMI S2-compatible Shroud. Use together with an A22E Emergency Stop Switch. Rated current Operating voltage VDC ...

Page 10

... Malfunction within 1 ms. 3. Setting and resetting once is counted as one operation. 4. The degree of protection from the front of the panel. http://www.ia.omron.com/ Emergency Stop Switches Non-lighted model: A22E 30 operations/minute max. (See note 3.) 30 operations/minute max. (See note 3.) 100 M min. (at 500 VDC Hz, 1.5-mm double amplitude (See note 2.) ...

Page 11

... A22E-L Large Push-lock, Turn-reset (60-dia.) 60 dia. A22E-SK Small Push-lock, Key-reset (30-dia.) 30 dia. 22 http://www.ia.omron.com/ A22E-LP Large Push-pull (60-dia. ) A22E-M Medium Push-lock, Turn-reset (40-dia dia. 1.8 A22E-MK Medium Push-lock, Key-reset (40-dia dia. 1.8 (c)Copyright OMRON Corporation 2007 All Rights Reserved. A22E 60 dia ...

Page 12

... Black letters Yellow Lock Ring A22Z-3360 30 dia. Material: Iron, zinc plated http://www.ia.omron.com/ Switch dimensions when mounted to a DPST-NO (or DPST-NC) one-piece Switch Block 41.2 Note: The operation unit is an example for the A22E-M. 30-dia. Resin Attachment A22Z-A30 2.5 Tightening Wrench A22Z-3905 8 dia. ...

Page 13

... Panel Cutout Dimensions +0.4 22.3 0 24.2± 0.2 +0.1 R1.7 0 Allowable panel thickness (c)Copyright OMRON Corporation 2007 All Rights Reserved. A22E 28 max. BA9S/13 Cable Draw-out Hole (Top View) 16±1 dia. (Side lead draw-out hole) Two, mounting holes 32 39 EMERGENCY OFF inscription plate (t=1) Rubber packing (t=0 ...

Page 14

... Switch Unit is attached. +0.5 25 dia. 0 (c)Copyright OMRON Corporation 2007 All Rights Reserved. A22E Note 1: The dimensions of the Shroud conform to the specifications of the SEMATECH Application Guide for SEMI S2-93. 2: These Shrouds are designed for use only in semiconductor manufacturing equipment. ...

Page 15

... Lighted with Voltage 1 X1 Reduction Unit 2 X2 Note: The above terminal connection diagrams are examples for SPST-NO + SPST-NC and DPST-NC. http://www.ia.omron.com/ Lighted Switch Blocks Lamp Socket Terminal connection (BOTTOM VIEW) DPST- (+) (− (c)Copyright OMRON Corporation 2007 All Rights Reserved. A22E ...

Page 16

... Lock Ring Mounting Ring (c)Copyright OMRON Corporation 2007 All Rights Reserved. A22E 2. The following diagram provides the dimensions for mounting Large Legend Plates with crimp terminals connected to Switch terminals Dimension min ...

Page 17

... Insert the Lamp Extractor (A22Z-3901) into the lamp, then rotate the Extractor while pressing it. http://www.ia.omron.com/ (2) Installing/Replacing on the Switch • Grip the indicator with your fingers, then rotate the indicator while pressing it against the Switch. (c)Copyright OMRON Corporation 2007 All Rights Reserved. A22E 17 ...

Page 18

... Use either of the following screwdrivers. Flat-head screwdriver Phillips screwdriver dia. Screwdriver (c)Copyright OMRON Corporation 2007 All Rights Reserved. A22E (2) Creating a Cable Port Hole Cable diameter Connector dia. A22Z-3500 dia. A22Z-3500-2 Wiring • Loosen the terminal screw from the Switch ...

Page 19

... Particularly scratches on the Operation Unit 8 mm dia. max. may create visual and operational obtrusions. Handle the Switches with care, and do not throw or drop them. 20.2 mm max. (c)Copyright OMRON Corporation 2007 All Rights Reserved. A22E 0 /time indicates that the estimated 0.16 mA 100 mA 1 ...

Page 20

... When transferring devices and equipment, be sure to keep one copy of the Operating Manual and pack another copy with the device or equipment so the person receiving it will have no problem operating it. • Related International Standards: ISO 12100 Basic Concepts, General Principles for Design IEC 61508 Functional Safety of Electrical/Electronic/Programmable Electronic Safety-related Systems http://www.ia.omron.com/ WARNING (c)Copyright OMRON Corporation 2007 All Rights Reserved. ...

Page 21

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords