CJ1WBAT01

Manufacturer Part Number
CJ1WBAT01
Description
BATTERY FOR CJ1M ONLY
Manufacturer
Omron
Datasheet

Specifications of CJ1WBAT01

Output Voltage
3 V
Capacity
850 mAh
Chemistry
Lithium
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Setting new standards in high-speed
machine control
Features
• Small, Fast, Flexible:
• Even more program memory and data memory.
• Superior high-speed control performance: LOAD instructions execute in 16 ns, SINE instructions in 0.59 μs.
• Maximum throughputs with High-speed interrupt function
• Efficient debugging through highly improved Data tracing
• Secure system from memory error brought by Memory Self-restoration Function
• The more advanced motion control by the lower cost: Synchronous Unit Operation
• Increased I/O throughput speed by Immediate refreshing instructions with direct processing.
SYSMAC CJ-series CJ2H CPU Units
CJ2H-CPU6@
Inheriting and improving CJ1 features, the CJ2 CPU Units
is the best choice for the machine control with high-speed
and high-capacity.
CJ2H-CPU64
CSM_CJ2H-CPU_DS_E_5_1
1

Related parts for CJ1WBAT01

CJ1WBAT01 Summary of contents

Page 1

SYSMAC CJ-series CJ2H CPU Units CJ2H-CPU6@ Setting new standards in high-speed machine control • Small, Fast, Flexible: Inheriting and improving CJ1 features, the CJ2 CPU Units is the best choice for the machine control with high-speed and high-capacity. Features • ...

Page 2

... The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives. • Contact your OMRON representative for further details and applicable conditions for these standards. CJ2H CPU Units ...

Page 3

General Specifications Item Enclosure Grounding CPU Rack Dimensions Weight Current Consumption Ambient Operating Temperature Ambient Operating Humidity Atmosphere Ambient Storage Temperature Altitude Pollution Degree Noise Immunity Use Environment Overvoltage Category EMC Immunity Level Vibration Resistance Shock Resistance Life Battery Model ...

Page 4

Performance Specifications Items User Memory I/O Bits Overhead Processing Time Execution Time Processing I/O Interrupts and Speed External Interrupts Interrupts Scheduled Interrupts Maximum Number of Connectable Units Maximum Number of Expansion Racks I/O Area Link Area Synchronous Data Refresh Area ...

Page 5

... Comparison Method: Equals (=), Greater Than (>), Greater Than or Equals (≥), Less Than (<), Less Than or Equals (≤), Not Equal (≠) −32,768 to +32,767 ms Memory Card (128, 256, or 512 Mbytes) (Use the Memory Cards provided by OMRON.) EM file memory (Part of the EM Area can be converted for use as file memory.) Capacity: 3.5 Mbytes 8 ports (Used for SEND, RECV, CMND, PMCR, TXDU, and RXDU instructions ...

Page 6

Function Specifications Functions Minimum Cycle Time Cycle Time Management Cycle Time Monitoring Background Processing Cyclic Refreshing Basic I/O I/O Units, Special Immediate Refreshing Refreshing I/O Units, and Refreshing by IORF CPU Bus Units Unit Recognition at Startup Input Response Time ...

Page 7

Function Communications Peripheral (USB) Peripheral Bus Port Serial Port Host Link (SYSWAY) Communications No-protocol Communications NT Link Communications Peripheral Bus Serial Gateway Scheduled Interrupts Power OFF Interrupts I/O Interrupt Tasks Interrupt External Interrupt Tasks High-speed Interrupt Function Clock Function Operation ...

Page 8

Function Error Log CPU Error Detection User-defined Failure Diagnosis Load OFF Function RUN Output Basic I/O Load Short-circuit Detection Failure Point Detection CPU Standby Detection System FAL Error Detection (User-defined non-fatal error) Duplicate Refreshing Error Detection Basic I/O Unit Error ...

Page 9

Function Simple Backup Function Unsolicited Communications Maintenance Remote Programming and Monitoring Automatic Online Connection via Network Read Protection using Password FINS Write Protection Security Unit Name Function Hardware ID Using Lot Numbers Unit Versions Units CJ2H CPU Units * Although ...

Page 10

Unit Version 1.2 or Later CX-Programmer version 8.3 or higher must be used to enable using the functions added for unit version 1.2. Unit Model Item EM force-set/reset function Note: User programs that use functions of CJ2H CPU Units with ...

Page 11

External Interface A CJ2H CPU Unit (CJ2H-CPU6@) provides two communications ports for external interfaces: a peripheral (USB) port and a serial port. Battery Compartment Simple Backup/Memory Card Power Supply Switch Used to back up Memory Card data or turn OFF ...

Page 12

Dimensions CJ2H CPU Unit CJ2H-CPU6@ 2.7 90 2.7 48.8 CJ2H-CPU6@ (Unit: mm) 66.2 65 74.5 12 ...

Page 13

Related Manuals Cat. No. Model CJ2H-CPU6@-EIP CJ-series CJ2 CPU Unit W472 CJ2H-CPU6@ Hardware User’s CJ2M-CPU@@ Manual CJ2H-CPU6@-EIP CJ-series CJ2 CPU Unit W473 CJ2H-CPU6@ Software User’s Manual CJ2M-CPU@@ CJ2H-CPU6@-EIP CJ2H-CPU6@ CJ2M-CPU3@ CJ2M-CPU1@ CS/CJ/NSJ-series CS1G/H-CPU@@H W474 Instructions Reference CS1G/H-CPU@@-V1 Manual CJ1G/H-CPU@@H CJ1G-CPU@@ ...

Page 14

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...