D4CC4024 Omron, D4CC4024 Datasheet

no-image

D4CC4024

Manufacturer Part Number
D4CC4024
Description
DC LOW OF RL LED
Manufacturer
Omron
Type
Limit Switchr
Datasheet

Specifications of D4CC4024

Pole Throw Configuration
SPDT
Switch Function Configuration
N.O./N.C.
Current Rating (max)
1A
Operating Temp Range
-10C to 70C
Lead Free Status / Rohs Status
Compliant
Many Models Including Roller Lever
Switches are Only 16-mm Thick with
Connector
• New center roller lever models that enable ganged mounting of up to
• Cable connectors for easy Switch replacement.
• Triple-seal construction to provide IEC IP67 degree of protection.
• Operation indicators available for easy monitoring (standard indicator
• Approved by UL and CSA.
Model Number Structure
Model Number Legend
D4CC-@0@@
(1) Rated Current
1 : 1 A at 125 VAC
2 : 1 A at 125 VAC (with LED indicator)
3 : 1 A at 30 VDC
4 : 1 A at 30 VDC (with LED indicator)
Ordering Information
Switches
Limit Switches
Note: 1. Ask your OMRON representative for Information on approved models.
Actuator
Pin
plunger
Roller
plunger
Crossroller
plunger
High-sensitivity
roller lever
Sealed pin
plunger
Sealed roller
plunger
Sealed crossroller
plunger
Plastic
rod
Center
roller lever
6 Switches.
is lit when Switch is not operating).
(Ask your OMRON representative for Information on approved
models.)
Miniature Limit Switch
D4CC
2. The meaning of suffix codes in the D4CC model numbers is different from that in the D4C model numbers.
3. Refer to the following table for cable plugs.
(1)
(2)
LED indicator
Ratings
(Not all combinations are possible. Ask your OMRON representative for details.)
Without indicator
D4CC-1001
D4CC-1002
D4CC-1003
D4CC-1024
D4CC-1031
D4CC-1032
D4CC-1033
D4CC-1050
D4CC-1060
Model
(2) Actuator
01 : Pin plunger
02 : Roller plunger
03 : Crossroller plunger
24 : Roller lever
31 : Sealed pin plunger
32 : Sealed roller plunger
33 : Sealed crossroller plunger
50 : Plastic rod
60 : Center roller lever
1 A at 125 VAC
With indicator
D4CC-2001
D4CC-2002
D4CC-2003
D4CC-2024
D4CC-2031
D4CC-2032
D4CC-2050
D4CC-2060
Model
---
Without indicator
D4CC-3001
D4CC-3002
D4CC-3003
D4CC-3024
D4CC-3031
D4CC-3032
D4CC-3033
D4CC-3050
D4CC-3060
Be sure to read Safety Precautions on page 7 to 8
and Safety Precautions for All Limit Switches.
Model
1 A at 30 VDC
CSM_D4CC_DS_E_3_1
With indicator
D4CC-4001
D4CC-4002
D4CC-4003
D4CC-4024
D4CC-4031
D4CC-4032
D4CC-4033
D4CC-4050
D4CC-4060
Model
1

Related parts for D4CC4024

D4CC4024 Summary of contents

Page 1

... D4CC-1050 rod Center D4CC-1060 roller lever Note: 1. Ask your OMRON representative for Information on approved models. 2. The meaning of suffix codes in the D4CC model numbers is different from that in the D4C model numbers. 3. Refer to the following table for cable plugs. (2) Actuator 01 : Pin plunger 02 : Roller plunger ...

Page 2

... Ambient operating humidity Weight Note: The above figures are initial values. *1. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales Volt-amperes (VA) representative for more detailed information on other operating environments. Make Break *2 ...

Page 3

Structure and Nomenclature Structure Center Roller Lever Models with Indicator O-ring (NBR) Nitrile rubber diaphragm Protective nitrile rubber cap (NBR) Open space (to reduce a change in internal pneumatic pressure and to prevent the respiratory movement of the Switch.) LED ...

Page 4

Dimensions and Operating Characteristics Switches Limit Switches The @ in each model number is replaced with the code expressing the rated load of the model. Refer to Model Number Legend. Pin Plunger 10 dia. D4CC-@001 stainless steel plunger 40 max. ...

Page 5

The @ in each model number is replaced with the code expressing the rated load of the model. Refer to Model Number Legend. Sealed Roller Plunger D4CC-@032 12 dia. × 4.4 stainless steel roller 40 max. PT ± 25 0.1 ...

Page 6

Special Mounting Plates (Limit Switches are not attached to the Plates.) D4C-P001 (For D4CC-@001) 34 (OP of WLD) D4C-P002 (For D4CC-@002) 44 (OP of WLD2) D4C-P020 (For D4CC-@024) 9.2 75 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies ...

Page 7

Safety Precautions Refer to Safety Precautions for All Limit Switches. Precautions for Correct Use Operating Environment • Seal material may deteriorate if a Switch is used outdoor or where subject to special cutting oils, solvents, or chemicals. Always appraise performance ...

Page 8

Plug Tightening • Connect the plug connector (B) to the connector threads (C) of the D4CC. Then firmly turn the plug connector by hand so that the connector threaded portion (C) will be completely covered by the plug connector (B) ...

Page 9

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords