E2E-X10F2 Omron, E2E-X10F2 Datasheet

Proximity Sensor (COO)

E2E-X10F2

Manufacturer Part Number
E2E-X10F2
Description
Proximity Sensor (COO)
Manufacturer
Omron
Series
E2Er
Datasheet

Specifications of E2E-X10F2

Proximity Sensor Type
Inductive
Output Type
PNP
Proximity Sensor Sensing Distance
10mm
Proximity Sensor Sensing Distance Range
7 to 15mm
Proximity Sensor Switching Mode
NC
Mounting
Panel
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
10V
Operating Supply Voltage (typ)
12/15/18/24V
Operating Supply Voltage (max)
40V
Pin Count
4
Maximum Operating Temperature
+ 85 C
Supply Voltage
10 V to 40 V
Operating Supply Voltage
10 V to 40 V
Mounting Style
Panel
Sensing Distance
10 mm
Minimum Operating Temperature
- 40 C
Features
NC
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
3kHz
Material - Body
Nickel-Plated Brass
Shielding
Shielded
Voltage - Supply
10 V ~ 30 V
Terminal Type
3-Wire
Package / Case
Cylinder, Threaded - M30
Lead Free Status / Rohs Status
Supplier Unconfirmed
A New Series of Easy-to-use
and Tough E2E/E2E2 Models
Long-size E2E2 Proximity Sen-
sor Conforms to CENELEC
• Ideal for a variety of applications.
• With a metal connector that can be tightened
• With an easy-to-see indicator, deeper mounting
• New 3-dia. size (sensing distance: 0.6 mm) added to
<READ AND UNDERSTAND THIS CATALOG>
Please read and understand this catalog before purchasing
the products. Please consult your OMRON representative if
you have any questions or comments.
Ordering Information
E2E
DC 2-wire/Pre-wired Models
Note 1. In addition to the above models, E2E-X@@15 models (e.g., E2E-X3D15-N), which are different in frequency from the above models, are
Yes
No
securely and a cable protector.
holes, and tightening flats for wrenches.
the lineup.
output function
Cylindrical Proximity Sensor
E2E/E2E2
Self-diagnostic
2. E2E models with a robotics cable are available as well. The model number of a model with a robotics cable has the suffix “-R”
3. Cables with a length of 5 m are also available. Specify the cable length at the end of the model number (e.g., E2E-X3D1-N 5M).
available.
(e.g., E2E-X3D1-R).
Shielded
Unshielded
Shielded
Unshielded
Size
M12
M18
M30
M12
M18
M30
M8
M12
M18
M30
M8
M12
M18
M30
3 mm
7 mm
10 mm
8 mm
14 mm
20 mm
2 mm
3 mm
7 mm
10 mm
4 mm
8 mm
14 mm
20 mm
Sensing distance
E2E-X3D1S (See note 1.)
E2E-X7D1S (See note 1.)
E2E-X10D1S (See note 1.)
E2E-X8MD1S (See note 1.)
E2E-X14MD1S (See note 1.)
E2E-X20MD1S (See note 1.)
E2E-X2D1-N (See notes 2 and 3.)
E2E-X3D1-N (See notes 1, 2 and 3.)
E2E-X7D1-N (See notes 1, 2 and 3.)
E2E-X10D1-N (See notes 1, 2 and 3.) E2E-X10D2-N
E2E-X4MD1 (See notes 2 and 3.)
E2E-X8MD1 (See notes 1, 2 and 3.)
E2E-X14MD1 (See notes 1, 2 and 3.)
E2E-X20MD1 (See notes 1, 2 and 3.
E2E/E2E2
NO
Cylindrical Proximity Sensor
Model
---
---
---
---
---
---
E2E-X2D2-N (See note 3.)
E2E-X3D2-N (See note 3.)
E2E-X7D2-N (See note 3.)
E2E-X4MD2
E2E-X8MD2
E2E-X14MD2
E2E-X20MD2
NC
1

Related parts for E2E-X10F2

E2E-X10F2 Summary of contents

Page 1

... E2E models with a robotics cable are available as well. The model number of a model with a robotics cable has the suffix “-R” (e.g., E2E-X3D1-R). 3. Cables with a length are also available. Specify the cable length at the end of the model number (e.g., E2E-X3D1-N 5M). Sensing distance ...

Page 2

... M12 Yes Shielded Unshielded No Shielded Unshielded M8 Shielded Unshielded Note: In addition to the above models, E2E-X@D15-M1G models (e.g., E2E-X3D15-M1G), which are different in frequency from the above models, are available. DC 2-wire/Pre-wired Connector Models Size Sensing distance Shielded M12 3 mm M18 7 mm M30 ...

Page 3

... E2E-X5F2 E2E-X10E1 (See notes and 4.) E2E-X10E2 (See notes 3 and 4.) E2E-X10F1 E2E-X10F2 Un- shielded Note 1. Models with a different frequency are also available. These models are E2E-X@Y@5 (e.g., E2E-X5Y15). 2. Cables with a length are also available. Specify the cable length at the end of the model number (e.g., E2E-X2Y1 5M) ...

Page 4

... E2E-X1R5F1-M1 E2E-X1R5F2-M1 E2E-X2E1-M1 E2E-X2E2-M1 E2E-X2F1-M1 Un- E2E-X2F2-M1 shielded E2E-X5E1-M1 E2E-X5E2-M1 E2E-X5F1-M1 E2E-X5F2-M1 E2E-X10E1-M1 E2E-X10E2-M1 AC/DC 2-wire/Pre-wired Models E2E-X10F1-M1 E2E-X10F2-M1 E2E-X2ME1-M1 E2E-X2ME2-M1 Shielded M12 E2E-X2MF1-M1 E2E-X2MF2-M1 E2E-X5ME1-M1 E2E-X5ME2-M1 Note 1. These models do not conform to CE standards. E2E-X5MF1-M1 E2E-X5MF2-M1 E2E-X10ME1-M1 E2E-X10ME2-M1 E2E-X10MF1-M1 E2E-X10MF2-M1 E2E-X18ME1-M1 E2E-X18ME2-M1 ...

Page 5

... M18 7 mm M30 10 mm Unshielded M12 8 mm M18 14 mm M30 20 mm Note: In addition to the above models, E2E-X@D15 models (e.g., E2E-X3D15), which are different in frequency from the above models, are available. DC 3-wire/Pre-wired Models Size Shielded M12 2 mm M18 5 mm M30 10 mm Unshielded ...

Page 6

... Sensing distance Operation mode Model E2E2-X2C1-M1 E2E2-X2C2-M1 E2E2-X2B1-M1 E2E2-X2B2-M1 E2E2-X5C1-M1 E2E2-X5C2-M1 E2E2-X5B1-M1 E2E2-X5B2-M1 E2E2-X10C1-M1 E2E2-X10C2-M1 E2E2-X10B1-M1 E2E2-X10B2-M1 E2E2-X5MC1-M1 E2E2-X5MC2-M1 E2E2-X5MB1-M1 E2E2-X5MB2-M1 E2E2-X10MC1-M1 E2E2-X10MC2-M1 E2E2-X10MB1-M1 E2E2-X10MB2-M1 E2E2-X18MC1-M1 E2E2-X18MC2-M1 E2E2-X18MB1-M1 E2E2-X18MB2-M1 Model E2E2-X2Y1 E2E2-X2Y2 E2E2-X5Y1 E2E2-X5Y2 E2E2-X10Y1 E2E2-X10Y2 E2E2-X5MY1 E2E2-X5MY2 E2E2-X10MY1 E2E2-X10MY2 E2E2-X18MY1 E2E2-X18MY2 ...

Page 7

... AC 2-wire/Connector Models Size Shielded M12 2 mm M18 5 mm M30 10 mm Unshielded M12 5 mm M18 10 mm M30 18 mm Sensing distance Operation mode E2E/E2E2 Model E2E2-X2Y1-M4 E2E2-X2Y2-M4 E2E2-X5Y1-M4 E2E2-X5Y2-M4 E2E2-X10Y1-M4 E2E2-X10Y2-M4 E2E2-X5MY1-M4 E2E2-X5MY2-M4 E2E2-X10MY1-M4 E2E2-X10MY2-M4 E2E2-X18MY1-M4 E2E2-X18MY2-M4 Cylindrical Proximity Sensor 7 ...

Page 8

... The residual voltage of each E2E model with the model number suffix “-M1J-T” When connecting an E2E model with the suffix “- M1J-T” device, make sure that the device can withstand the residual voltage. ...

Page 9

... Note 1. The response speed is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. 2. When using an E2E with an M8 connector at an ambient temperature range between 70 ° C and 85 ° C, supply VDC to the E2E and make sure that the E2E has a control output of 100 mA maximum. ...

Page 10

... E2E-C@C@/B@, E2E-X1C@/B@ DC 3-wire Models Size Type Item Sensing distance Set distance Differential travel Sensing object Standard sensing object Response speed (See note.) Power supply voltage (operating voltage range) Current consumption Control output Load current Residual voltage Indicator Operation mode (with sensing object ...

Page 11

... Instruction manual Note 1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is over –25 ° When using an M18-or M30-sized E2E within an ambient temperature of 70 ° ° C, make sure that the E2E has a control output 200 mA max. ...

Page 12

... IEC 60529 IP67 In-house standard for oil resistance (former JEM standard equivalent to IP67g) Pre-wired Models (standard length 2 m) Approx Approx. 140 g Brass-nickel plated Brass-nickel plated Instruction manual M18 M30 Shielded E2E-X7T1 E2E-X10T1 10 mm ± 10 8.0 mm Iron 0.4 kHz (See note 3.) Approx. 190 g ...

Page 13

... Accessories Instruction manual Note 1. Use the E2E2 within the range in which the setting indicator (green LED) is lit (except D2 models). 2. The response speed is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. ...

Page 14

... E2E2-X@C@/B@ DC 3-wire Models Size Type Shielded Item E2E2-X2C ± 10% Sensing distance Set distance 0 to 1.6 mm Differential travel 10% max. of sensing distance Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal, refer to Engineering Data.) Standard sensing Iron object 1 mm Response speed (See 1 ...

Page 15

... Instruction manual Note 1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is –25 ° ° When using an M18-or M30-sized E2E2 within an ambient temperature of 70 ° ° C, make sure that the E2E2 has a control output 200 mA maximum. ...

Page 16

... E2E/E2E2 16 Cylindrical Proximity Sensor E2E-X@E@/F@ E2E-X@ −15 −10 − Distance Y (mm) E2E-X@ME@/F@ E2E-X@MY E2E-X18M 15 E2E-X10M 10 E2E-X5M E2E-X2M 5 0 −30 −20 − Distance Y (mm) E2E-C@C@/B@ E2E-X@C@/B@ 1.6 Y 1.4 E2E-X10 X 1.2 1.0 0.8 E2E-X5 0.6 E2E-X2 0.4 E2E -X1R5 0.2 0 −3.0 −2.0 −1 ...

Page 17

... Load current (mA) E2E-X@Y@ 24 VAC Residual output voltage Proximity Sensor 24 VAC Residual load voltage OFF Load current (mA) E2E-X@Y@ Proximity Protective Sensor resistance (when OFF) AC power supply Supply voltage (V) E2E-X@T1 200 VAC 100 VAC 24 VDC 100 Load current (mA) 100 VAC Residual output voltage ...

Page 18

... Brass Aluminum Copper Side length of sensing object d (mm) E2E-X20MD@ Iron Stainless steel (SUS304) Brass Aluminum Copper Side length of sensing object d (mm) E2E-X7D@ E2E-X7T1 Iron Stainless steel (SUS304) Brass Aluminum Copper Side length of sensing object d (mm) E2E-X8MD Iron Stainless steel (SUS304) ...

Page 19

... Stainless steel 0.5 (SUS304) Brass 0.4 Aluminum 0 Side length of sensing object d (mm) E2E/E2E2 E2E-X10E@F@ E2E-X10Y@ Iron Stainless steel (SUS304 Aluminum Side length of sensing object d (mm) E2E-X10ME@/F@ E2E-X10MY Stainless steel (SUS304 Aluminum Side length of sensing object d (mm) E2E-CR8 Iron ...

Page 20

... Distance Y (mm) Leakage Current (Typical) E2E2-X@D@ Supply voltage (V) E2E/E2E2 20 Cylindrical Proximity Sensor E2E2-X@C@/B@ E2E2-X@Y@ 3.0 2.5 Y 2.0 X E2E2-X2 1.5 1.0 0 -15 - Distance Y (mm) E2E2-X@MC@/B@ E2E2-X@MY Distance Y (mm) E2E2-X@Y@ Proximity Protective Sensor resistance (when OFF) AC power supply Supply voltage ( ...

Page 21

... Residual load voltage OFF Load current (mA) E2E2-X7D@ Iron Stainless steel (SUS304) Brass Aluminum Copper Side length of sensing object d (mm) E2E/E2E2 200 VAC Residual output voltage Proximity Sensor 200 VAC Residual load voltage OFF Load current (mA) E2E2-X10D@ Iron Stainless steel (SUS304) Brass ...

Page 22

... Brass Aluminum Side length of sensing object d (mm) E2E2-X10MC@/B@ E2E2-X10MY@ Iron Stainless steel (SUS304) Brass t-=1 mm Aluminum Side length of sensing object d (mm) E2E2-X20MD@ Iron Stainless steel (SUS304) Brass Aluminum Copper t=1 mm Side length of sensing object d (mm) E2E2-X10C@/B@ E2E2-X10Y@ Iron Stainless steel (SUS304) ...

Page 23

... V * Constant current output is 1 mA. ** When connecting circuit. *** Pin contact, and pin contact. E2E-C/X@B@ PNP Open-collector Output Load Proximity sensor main circuit E2E-CR6@ has no 100-Ω resistance. E2E/E2E2 E2E-X@D1S With Diagnostic Output 4 Brown Load (0 V) Load Proximity sensor Orange (diagnostic main ...

Page 24

... Pin contact, and pin contact. E2E2-X@Y@ DC 2-wire Models Brown 2 Load Proximity sensor main circuit Blue 3 E2E/E2E2 24 Cylindrical Proximity Sensor E2E-X@T1 AC/DC 2-wire Models Brown 3 (or 1) Load Blue 4 (or 2) E2E2-X@B@ DC 3-wire Models + V Proximity sensor main circuit 100 Ω Pin contact, and pin contact. ...

Page 25

... Setting indicator (green) Operation indicator (red) Control output Setting indicator (green) Note: The diagnostic output of the E2E-X@D1S is ON when there is a coil burnout or the Operation sensing object is located in the unstable indicator (red) sensing range for 0 more. Control output Diagnostic output (see note) ...

Page 26

... Sensing object E2E2-X@C@/B@ DC 3-wire Models NPN/PNP Open-collector Output Yes Sensing object No ON Operation OFF indicator (red) ON Control output OFF E2E2-X@Y@ AC 2-wire Models Yes Sensing object No ON Operation OFF indicator (red) ON Control output OFF E2E/E2E2 26 Cylindrical Proximity Sensor NC Models Non-sensing area ...

Page 27

... E2E-X@E@ DC 3-wire Models Brown Black Blue 24 VDC E2E-X@E@ DC 3-wire Models Brown Black 24 VDC Blue E2E/E2E2 E2E-X@D1-M1J-T DC 2-wire Models (No Polarity) E2E-X@Y@ AC 2-wire Models E2E-X@T1 AC/DC 2-wire Models Brown Load Power supply Blue Note: There is no need to be ...

Page 28

... E2E2-X@Y@ AC 2-wire Models Brown Load Power supply Blue Note: The load can be connected as shown in the above diagrams. Connected to PC E2E2-X@D@ DC 2-wire Models Brown Blue 24 VDC E2E/E2E2 28 Cylindrical Proximity Sensor Brown Power supply Blue Load E2E2-X@C@ DC 3-wire Models Brown Black Blue 24 VDC ...

Page 29

... Pin Arrangement E2E-X@D@-M@ DC 2-wire Models Connector Self- Opera- Applicable diagnostic tion output mode M12 No NO E2E-X@D1-M1G@ (See note.) E2E-X@D1-M1J-T E2E-X@D1-M1 NC E2E-X@D2-M1G (See note.) E2E-X@D2-M1 Yes NO E2E-X@D1S- E2E-X@D1-M3G NC E2E-X@D2-M3G Note: The above pin arrangements conform to IEC standards. models Load Note: Terminals 2 and 3 are not used. ...

Page 30

... E2E-X@E/F@-M@ DC 3-wire Models Connector Operation mode M12 E2E/E2E2 30 Cylindrical Proximity Sensor Applicable models E2E-X@E1-M1 Load E2E-X@F1-M1 Load E2E-X@E2-M1 Load E2E-X@F2-M1 Load E2E-X@E1-M3 Load E2E-X@F1-M3 Load E2E-X@E2-M3 Load E2E-X@F2-M3 Load Pin arrangement Note: Terminal 2 is not used. Note: Terminal 2 is not used. ...

Page 31

... Note: Terminals 3 and 4 are not used. Refer to the following to mount the E2E-CR6, -CR8 and E2E-C1 non-screw models. Tighten the screw to a torque of 0.2 N·m maximum to secure the E2E-CR6, -CR8 and a torque of 0.4 N·m maximum to secure the E2E-C1. Part B Part A Part B Torque 12 N· ...

Page 32

... Influence of Surrounding Metal When mounting the E2E within a metal panel, ensure that the clearances given in the following table are maintained. Failure to maintain these distances may cause deterioration in the performance of the sensor. Model E2E-X@D@ Shielded DC 2-wire E2E-X@T1 AC/DC 2-wire E2E2-X@D@ DC 2-wire Unshielded ...

Page 33

... E2E-X5Y@ E2E-X7T1 Unshielded E2E-X14MD@ E2E-X10ME@/F@ E2E-X10MY@ M30 Shielded E2E-X10D@ E2E-X10E@/F@ E2E-X10Y@ E2E-X10T1 Unshielded E2E-X20MD@ E2E-X18ME@/F@ E2E-X18MY@ E2E2 Model M12 Shielded E2E2-X3D@ E2E2-X2C@/B@ E2E2-X2Y@ Unshielded E2E2-X8MD@ E2E2-X5MC@/B@ E2E2-X5MY@ M18 Shielded E2E2-X7D@ E2E2-X5C@/B@ E2E2-X5Y@ Unshielded E2E2-X14MD@ E2E2-X10MC@/B@ E2E2-X10MY@ M30 Shielded E2E2-X10D@ E2E2-X10C@/B@ E2E2-X10Y@ ...

Page 34

... Shielded DC 2-wire E2E-X@T1 Unshielded AC/DC 2-wire E2E2-X@D@ DC 2-wire E2E-X@E@ Shielded E2E-X@F@ DC 3-wire Unshielded E2E-X@Y@ AC 2-wire E2E2-X@B@ E2E2-X@C@ DC 3-wire E2E2-X@Y@ AC 2-wire Model E2E-X@B@ Shielded E2E-X@C@ E2E-C@B@ E2E-C@C@ DC 3-wire Note: Values in parentheses apply to Sensors operating at different frequencies. E2E/E2E2 34 Cylindrical Proximity Sensor B A Item ...

Page 35

... Load Brown Incorrect Sensor Blue DC 2-wire Models The following diagram shows that the load is short-circuited while the polarity of the supply voltage imposed on the E2E/E2E2 is wrong, in which case the E2E/E2E2 may explode or burn. Load Brown (Load short-circuit) Incorrect Sensor Blue Brown Load ...

Page 36

... R ≤ V /(10 – Ω > (mW) S E2E/E2E2 36 Cylindrical Proximity Sensor Environment Water Resistivity Do not use the Proximity Sensor underwater, outdoors the rain. Operating Environment Be sure to use the Proximity Sensor within its operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained ...

Page 37

... AND (serial connection) OR (parallel connection) AC 2-wire AND (serial connection) Example In this example, the above conditions are checked for when the PLC model is the C200H-ID212, the Proximity Sensor model is the E2E- X7D1-N, and the power supply voltage (14.4 V) ≤ (1.3 mA) ≥ OFF 3 ...

Page 38

... Model Connection type AC 2-wire OR (parallel connection 3-wire AND (serial connection) E2E/E2E2 38 Cylindrical Proximity Sensor Method In principle, more than two Proximity Sensors cannot Incorrect be connected in parallel. Load Provided that Proximity Sensor A does not operate B with Proximity Sensor B simultaneously and there is no need to keep the load operating continuously, the Proximity Sensors can be connected in parallel ...

Page 39

... E2E-X4MD@ ed M12 E2E-X8MD@ M18 E2E-X14MD@ M30 E2E-X20MD@ Connector Shielded M8 E2E-X2D@-M1(G) (M12) M12 E2E-X3D@-M1(G) M18 E2E-X7D@-M1(G) M30 E2E-X10D@-M1(G) Unshield- M8 E2E-X4MD@-M1( M12 E2E-X8MD@-M1(G) 21 M18 E2E-X14MD@- M1(G) M30 E2E-X20MD@- M1(G) Connec- Shielded 4 dia. --- tor (M8-3 M5 --- pin) Connector Shielded M8 E2E-X2D@-M3G ...

Page 40

... Pre-wired Models (Shielded) Fig. 1: E2E-CR6@@ 27 3±0.1 dia. 17 Operation 2.4-dia. (7/0.127-dia.) vinyl-insulated round cable indicator with 3 conductors, (red) Standard length Fig. 2: E2E-CR8 dia. 17.5 Operation 2.9-dia. vinyl-insulated round cable with indicator 3 conductors (Conductor cross section: 0.14 mm (red) Insulator diameter: 0.9 mm), Standard length Robotics cable Models: 2 ...

Page 41

... M30 × 1.5 Two clamping nuts Toothed washer Note Models: Operation indicator (red), setting indicator (green); E,F,Y Models: Operation indicator (red) Pre-wired Models (Unshielded) Fig. 12: E2E-X5MY@ 21 dia. 17 4-dia. vinyl-insulated round cable with 2 conductors (Conductors cross section: 0 Insulator diameter: 1.3 mm), Standard length The cable can be extended up to 200 m (separate metal conduit) ...

Page 42

... E, F Model: Operation indicator (red) Fig. 21: E2E-X8MD@-M1(G) E2E-X5ME@-M1/F@-M1 21 dia. 17 M12 × 1 Note: D Models: Operation indicator (red), setting indicator (green Model: Operation indicator (red) Fig. 23: E2E-X5MY@-M1 21 dia. 17 M12 × 1 Fig. 25: E2E-X14MD@-M1(G)/E2E-X10ME@-M1/F@-M1 E2E-X10MY@-M1 29 dia. 24 M12 × 1 Indicator (See note ...

Page 43

... Note: D Models: Operation indicator (red), setting indicator (green Model: Operation indicator (red) Pre-wired M12 Connector Models Fig. 30: E2E-X3D1-M1GJ E2E-X3D1-M1J-T 21 dia. 17 Fig. 31: E2E-X8MD1-M1GJ 21 dia. 17 Fig. 32: E2E-X7D1-M1GJ E2E-X7D1-M1J-T 29 dia. 24 Fig. 37: E2E-X1@@-M5 10 dia. 8 M8, 3-pin connector M8 Connector Models (Unshielded) Fig. 29: E2E-X4MD@-M3G/E2E-X2ME@-M3/F@-M3 15 dia ...

Page 44

... Pre-wired M12 Connector Models Fig. 33: E2E-X14MD1-M1GJ 29 dia. 24 Fig. 34: E2E-X10D1-M1GJ E2E-X10D1-M1J-T 42 dia. 36 Fig. 35: E2E-X20MD1-M1GJ 42 dia. 36 Mounting Holes F Dimensions 3 dia. 4 dia. F (mm) +0.3 +0.5 3.3 / dia. 4 E2E/E2E2 44 Cylindrical Proximity Sensor 14.8 dia. Operation indicator (red), M18 × 1 setting indicator (green) Two clamping nuts ...

Page 45

... M30 × 1.5 Two clamping nuts Toothed washer Note: D Models: Operation indicator (red), setting indicator (green Model: Operation indicator (red) E2E2-X8MD@ E2E2-X5M dia dia. Note: D Models: Operation indicator (red Insulator diameter: 1.3 mm), setting indicator (green Model: Operation indicator (red) ...

Page 46

... Two clamping nuts Toothed washer E2E/E2E2 46 Cylindrical Proximity Sensor Connector Models (Unshielded) E2E2-X5MC@-M1/B@-M1 21 dia. 17 M12 x 1 Operation indicator (red) E2E2-X5MY@-M4 21 dia. 17 1/2-20unf Operation indicator (red) E2E2-X10MC@-M1/B@-M1 29 dia 10 24 M12 x 1 Operation indicator (red) E2E2-X10MY@-M4 29 dia ...

Page 47

... E2E2-X18MC@-M1/B@-M1 42 dia M12 x 1 Operation indicator (red) E2E2-X18MY@-M4 42 dia 1/2-20unf Operation indicator (red) M30 + 0.5 dia. 30.5 dia. 0 E2E/E2E2 M12 x 1 26.8 dia. Operation indicator (red) M30 x 1.5 Two clamping nuts Toothed washer 1/2-20unf 26.8 dia. Operation indicator (red) M30 x 1 ...

Page 48

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords