Specifications of MKS3P-5 AC120

Contact Form
3DPT
Coil Voltage
120 VAC
Contact Rating
10 A
Contact Termination
Quick Connect
Mounting Style
Plug-In
Power Consumption
2.3 VA to 2.7 VA
Contact Material
Silver Alloy
Coil Current
19.3 mA
Coil Resistance
1130 Ohms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Exceptionally Reliable General Purpose
Relay now available with Lockable Test
Button
• IEC Rating of 7A 250 V AC 50/60 Hz,
• Mechanical indicator standard for all models.
• Optional features include lockable test button, LED
• UL (RU/
• RoHS Compliant.
Features
Two-way Action Test Button
Model Number Structure
■ Model Number Legend
1. Contact Form
2. Terminals
3. Mechanical Indicator/Test Button
4. LED Indicator
MKS@@@@@-@-@
General use 100,000 cycles.
indicator, diode surge suppression, varistor, reverse
polarity, and alternate wiring styles.
General Purpose Relays
MKS
2:
3:
P:
Blank:Mechanical indicator
I:
Blank: Standard
N:
1 2 3 4 5
DPDT
3PDT
Plug-in
Mechanical indicator and lockable test button
LED indicator
C
RU), CE and TUV approved.
6
7
Normal Operation
Relay in
Yellow
button
Pull down the test
button to the first
position, then press the
yellow button with an
insulated tool to
operate the contact.
For Momentary
Operation
5. Coil Polarity
6. Surge Absorption
7. Internal Connections DPDT
8. Rated Voltage
Blank: Standard
1:
Blank:Standard
D:
V:
Blank: Standard
2 :
Internal Connections 3PDT
5 :
Blank: Non Standard
2 :
(Refer to “Coil Ratings”.)
Reverse polarity (DC coil only)
Surge absorber diode (DC coil only)
Surge absorber varistor (AC coil only)
Non Standard
Standard
Non Standard
Pull down the test
button to the second
position.
(The contact is now in
the locked position.)
General Purpose Relays
Operation
For Lock
MKS
277

Related parts for MKS3P-5 AC120

MKS3P-5 AC120 Summary of contents

Page 1

General Purpose Relays MKS Exceptionally Reliable General Purpose Relay now available with Lockable Test Button • IEC Rating of 7A 250 V AC 50/60 Hz, General use 100,000 cycles. • Mechanical indicator standard for all models. • Optional features include ...

Page 2

... Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications. Example: MKS2P DC48 2. The DC coil comes in two types: standard coil polarity and reverse coil polarity. Refer to Terminal Arrangement and Internal Connections. Example: MKS3PN1-5 DC24 3. Refer to Terminal Arrangement and Internal Connections for all wiring diagrams. ■ 10A Sockets (Order Separately) Item ...

Page 3

Specifications ■ Ratings Coil Ratings Rated voltage Rated current 443 mA 385 221 mA 193 110 mA 96.3 mA 110 V 24.2 mA 21.0 mA 120 V ...

Page 4

Characteristics Contact resistance 100 mΩ max. Operate time AC max. DC max. Release time 20 ms max.(40 ms max. for built-in diode models) Max. operating frequency Mechanical: 18,000 operations/hr (no load) Electrical:1,800 operations/hr (at rated ...

Page 5

Dimensions Note: All units are in millimeters unless otherwise indicated. Models without Test Button 34.5 max. 34.5 max. 0.8 52.5 max. Track Mounted Sockets See below for Socket dimensions. Poles Finger-protection models Maximum carry current poles PF083A-E ...

Page 6

PF083A Eight, M4 screws 65 38 Hold-down Clips PFC-A1 (2 pieces per set) 4.6 60 4.5 Mounting Tracks PFP-100N, PFP-50N (Conforming to EN 50022) 7.3±0.15 4 (5) ...

Page 7

... Standard Polarity Diode Type MKS2P(I)1-D (DC Coil Reverse Polarity MKS2P(I)-2 MKS3P( MKS2P(I)N-2 MKS3P(I MKS2P(I)N-2 MKS3P(I MKS2P(I)N1-2 MKS3P(I) MKS2P(I)-D-2 MKS3P(I)- MKS2P(I)1-D-2 MKS3P(I)1 General Purpose Relays (Bottom View) MKS3P(I)-2 MKS3P(I)- MKS3P(I)N-2 MKS3P(I)N MKS3P(I)N-2 MKS3P(I)N MKS3P(I)N1-2 MKS3P(I)N1 MKS3P(I)-D-2 MKS3P(I)-D MKS3P(I)1-D-2 MKS3P(I)1-D MKS 283 ...

Page 8

... Relay complete condition, i.e. with the nameplate, nameplate frame, test button, and slider in place. If any of these parts are removed, only the requirements for basic insulation are fulfilled. 284 General Purpose Relays MKS2P(I)N-D-2 MKS3P(I)N MKS2P(I)-V-2 MKS3P(I)- MKS2P(I)N-V-2 MKS3P(I)N MKS MKS3P(I)N-D-2 MKS3P(I)N-D MKS3P(I)-V-2 MKS3P(I)-V MKS3P(I)N-V-2 MKS3P(I)N-V ...

Page 9

... Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER’ ...

Page 10

... THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ...

Related keywords