ZEN222 Omron, ZEN222 Datasheet
ZEN222
Specifications of ZEN222
Related parts for ZEN222
ZEN222 Summary of contents
Page 1
... N21 : Sealed crossroller plunger (ZE, ZV, ZV2 only) NA2 : Sealed roller arm lever NA277 : Sealed one-way action roller arm lever * Consult with your OMRON representative concerning availability, pricing, and delivery of conduit sizes and ground terminal specifications other than those on standard models. : Plunger ...
Page 2
... Note: 1. The diagonal side mounting model feature improved sealing property, improved mounting strength through use of M5 screws, increased stability in seating with large mounting width ( mm) and permit coupling of a number of Switch units. 2. Ask your OMRON representative for information on models with ground terminals. Specifications ...
Page 3
... Note: The above figures are initial values. *1. IP65 for @-N models and IP60 for @-Q models. *2. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments. *3. At the operation limit positions. ...
Page 4
Structure and Nomenclature Structure ZE-NA2-2 Pin plunger Tightening band Case Conduit Cover Seal rubber (NBR) opening Note: The conduit thread indication has been changed from "PF1/2" to "G1/2" accompanying the JIS B 0202 revision. This changes applies only to the ...
Page 5
One-way Action Roller Arm Lever ZE-QA277-2 × 18.7 dia XE-QA277-2 JIS B0202 G1/2 Effective thread: 4 threads min. 17 Two, M4 (length: 45) 23 ± 25.4 0.3 *1. Stainless sintered alloy roller *2. Adjustable between 0° and 225° ...
Page 6
Base Mounting/Diagonal Side Mounting Models The diagrams show the base-mounted model (ZV-@ or XV-@) on top and the diagonal side-mounted model (ZV2-@ or XV2-@) on bottom. The flange on base-mounted models is shown with dotted lines. Plunger ZV(2)-Q ...
Page 7
One-way Action Roller Arm Lever ZV2-QA277-2 XV(2)-QA277-2 t=3 (ZV-NA277-2/XV-NA277-2 flanges) 53R ± × Two, 4.3 0.2 dia. holes 18.7 dia (40) JIS B0202 G1/2 R17.4 Effective thread: 4 threads min +0.2 Two, 5.4 dia. ...
Page 8
Sealed Roller Arm Lever ZV(2)-NA2-2 XV(2)-NA2-2 t=3 (ZV-NA2-2/XV-NA2-2 flanges) 53R ± Two, 4.3 0.2 dia. × 19.1 dia JIS B0202 (23.1) G1/2 Effective thread: 4 threads min ± +0.2 Two, 5.4 dia. 25.4 0.3 ...
Page 9
Mounting • With the Roller Lever-type Enclosed Switches, the roller arm has been temporarily tightened prior to shipment, so that its position may be adjusted later. When mounting the Switch, be sure to re- tighten the roller arm so as ...
Page 10
... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...
Page 11
... São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS MEXICO • HEAD OFFICE Apodaca, N.L. • 52.811.156.99.10 • 001.800.556.6766 • mela@omron.com OMRON EUROpE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu CSM_ZE_ZV_ZV2_XE_XV_XV2_DS_E_2_1 OMRON ARGENTINA • SALES OFFICE Cono Sur • ...