E3X-CN11-R 2M Omron, E3X-CN11-R 2M Datasheet - Page 10

no-image

E3X-CN11-R 2M

Manufacturer Part Number
E3X-CN11-R 2M
Description
E3X Photoelectric Switch
Manufacturer
Omron
Datasheet

Specifications of E3X-CN11-R 2M

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
10
E3X-SD/-NA
I/O Circuit Diagrams
Note: Timing Charts for Timer Settings (T: Set Time)
Plug (Sensor I/O Connector)
NPN
Output
PNP
Output
Output
form
3
No incident light
4
Incident light
2
L-ON
D-ON
1
E3X-SD21
E3X-SD7
E3X-NA11
E3X-NA6
E3X-NA11F
E3X-NA11V
E3X-NA14V
E3X-SD51
E3X-SD9
E3X-NA41
E3X-NA8
E3X-NA41F
E3X-NA41V
E3X-NA44V
OFF delay
OFF
OFF
Model
Terminal number
ON
ON
1
2
3
4
XS3F-M421-402-A
XS3F-M421-405-A
T
operation mode
T
transistor
Light-ON
Dark-ON
Light-ON
Dark-ON
Output
XS3F-M422-402-A
XS3F-M422-405-A
Operation
indicator
(orange)
Output
transistor
Load
(relay)
Operation
indicator
(orange)
Output
transistor
Load
(relay)
Operation
indicator
(orange)
Output
transistor
Load
(relay)
Operation
indicator
(orange)
Output
transistor
Load
(relay)
No incident light
No incident light
No incident light
No incident light
(Between brown and black leads)
(Between brown and black leads)
(Between blue and black leads)
(Between blue and black leads)
Incident light
Incident light
Incident light
Incident light
Wire color
Timing charts
Operate
Operate
Operate
Operate
Reset
Reset
Reset
Reset
Brown
White
Blue
Black
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
T
T
T
T
Note: Pin 2 is not used.
Classification
DC
Operation
LIGHT ON
LIGHT ON
DARK ON
DARK ON
selector
(L-ON)
(D-ON)
(L-ON)
(D-ON)
Wire color
Brown
White
Black
Blue
• M8 Connector Pin Arrangement
Note: Pin 2 is not used.
• M8 Connector Pin Arrangement
Note: Pin 2 is not used.
Operation
indicator
(orange)
Operation indicator
(orange)
Photo-
electric
Sensor
main
circuit
Photo-
electric
Sensor
main
circuit
Connection pin
1
2
3
4
Output circuit
✽ Not present on the E3X-NA.
✽ Not present on the E3X-NA.
Power supply (0 V)
Power supply (+V)
1
1
1
4
3
1
4
3
2
2
Brown
Black
Blue
Brown
Black
Blue
Application
4
4
3
3
Output
Control output
---
Control output
Load
Load
12 to
24 VDC
12 to
24 VDC

Related parts for E3X-CN11-R 2M