G3NA-440B-DC5-24 Omron, G3NA-440B-DC5-24 Datasheet - Page 3

SOLID STATE RELAY

G3NA-440B-DC5-24

Manufacturer Part Number
G3NA-440B-DC5-24
Description
SOLID STATE RELAY
Manufacturer
Omron
Series
G3NAr
Datasheet

Specifications of G3NA-440B-DC5-24

Circuit
SPST-NO (1 Form A)
Output Type
AC, Zero Cross
Load Current
40A
Voltage - Input
5 ~ 24VDC
Voltage - Load
180 ~ 528 V
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Package / Case
Hockey Puck
Control Voltage Range
5 VDC to 24 VDC
Load Voltage Rating
200 VAC to 480 VAC
Load Current Rating
40 A
Contact Form
1 Form A
Mounting Style
DIN Rail
Input To Output Isolation Method
Photocoupler
Relay Type
General Purpose Hockey Puck
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G3NA-440B-DC5-24
G3NA440BDC524
Z2588
Specifications
■ Input Ratings
(Ambient temperature: 25°C [77°F])
Note: 1. The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 120 VAC,
■ Output Ratings
G3NA-2❏❏B
G3NA-4❏❏B
G3NA-D210B
G3NA-275B-UTU
G3NA-290B-UTU
G3NA-475B-UTU
G3NA-490B-UTU
G3NA-205B
G3NA-210B
G3NA-410B
G3NA-220B
G3NA-420B
G3NA-240B
G3NA-440B
G3NA-450B
G3NA-D210B
G3NA-275B-UTU 24 to 240 VAC
G3NA-475B-UTU 200 to 480 VAC
G3NA-290B-UTU 24 to 240 VAC
G3NA-490B-UTU 200 to 480 VAC
*When the appropriate size OMRON heat sink is used.
2. With constant current input circuit system, the impedance for the G3NA-2❏❏B-UTU is 15mA max.
3. Refer to the “Characteristic Data” for further details.
Type
Type
the input impedance is measured at 120 VAC).
5 to 24 VDC
100 to 120 VAC
200 to 240 VAC
5 to 24 VDC
100 to 240 VAC
5 to 24 VDC
100 to 240 VAC
24 to 240 VAC
24 to 240 VAC
200 to 480 VAC
24 to 240 VAC
200 to 480 VAC
24 to 240 VAC
200 to 480 VAC
200 to 480 VAC
5 to 200 VDC
load voltage
voltage
Rated
Rated
4 to 32 VDC
75 to 132 VAC
150 to 264 VAC
4 to 32 VDC
75 to 264 VAC
4 to 32 VDC
75 to 264 VAC
19 to 264 VAC
19 to 264 VAC
180 to 528 VAC
19 to 264 VAC
180 to 528 VAC
19 to 264 VAC
180 to 528 VAC
180 to 528 VAC
4 to 220 VDC
19 to 264 VAC
180 to 528 VAC
19 to 264 VAC
180 to 528 VAC
voltage range
voltage range
Operating
Load
7 mA max.
36 kΩ ±20%
72 kΩ ±20%
5 mA max.
72 kΩ ±20%
15 mA max.
72 kΩ ±20%
0.1 to 5 A (at 40°C)
0.1 to 10 A (at 40°C)
0.2 to 10 A (at 40°C)
0.1 to 20 A (at 40°C)
0.2 to 20 A (at 40°C)
0.1 to 40 A (at 40°C)
0.2 to 40 A (at 40°C)
0.2 to 50 A (at 40°C)
0.1 to 10 A (at 40°C)
1 to 75 A (at 40°C)
1 to 75 A (at 40°C)
1 to 90 A (at 40°C)
1 to 90 A (at 40°C)
With heat sink*
(See note 1)
Impedance
Applicable load
(see note 2)
(see note 2)
(see note 2)
Load current
4 VDC max.
75 VAC max.
150 VAC max.
4 VDC max.
75 VAC max.
4 VDC max.
75 VAC max.
0.1 to 3 A (at 40°C)
0.1 to 4 A (at 40°C)
0.2 to 4 A (at 40°C)
0.1 to 4 A (at 40°C)
0.2 to 4 A (at 40°C)
0.1 to 6 A (at 40°C)
0.2 to 6 A (at 40°C)
0.2 to 6 A (at 40°C)
0.1 to 4 A (at 40°C)
1 to 7 A (at 40°C)
1 to 7 A (at 40°C)
1 to 7 A (at 40°C)
1 to 7 A (at 40°C)
Must operate voltage
Solid State Relay
Without heat sink
(see note 3)
(see note 3)
Voltage level
1 VDC min.
20 VAC min.
40 VAC min.
1 VDC min.
20 VAC min.
1 VDC min.
20 VAC min.
60 A (60 Hz, 1 cycle)
150 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
20 A (10 ms)
800 A (60 Hz, 1 cycle)
800 A (60 Hz, 1 cycle)
1,000 A (60 Hz, 1 cycle)
1,000 A (60 Hz, 1 cycle)
G3NA
Must release voltage
Surge current
(see note 3)
(see note 3)
453