G5CA-1A4 DC12 Omron, G5CA-1A4 DC12 Datasheet - Page 5

POWER PCB RELAY

G5CA-1A4 DC12

Manufacturer Part Number
G5CA-1A4 DC12
Description
POWER PCB RELAY
Manufacturer
Omron
Series
G5CAr
Datasheet

Specifications of G5CA-1A4 DC12

Relay Type
General Purpose
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
10A
Switching Voltage
250VAC, 125VDC - Max
Coil Type
Standard
Coil Current
16.7mA
Coil Voltage
12VDC
Turn On Voltage (max)
9 VDC
Turn Off Voltage (min)
1.2 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
10A @ 250VAC
Control On Voltage (max)
9 VDC
Control Off Voltage (min)
1.2 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G5CA-1A4-DC12
G5CA1A4DC12
Z2156
Precautions
■ Precautions for Correct Use
Installation
Make sure that sufficient space is provided between relays when
installing two or more relays side by side to facilitate heat dissipation.
Insufficient heat dissipation may result in the relay malfunctioning.
.
Quick-connect Terminal Connections
• Do not pass current through the PCB of the load contact terminals
• The terminals are compatible with Faston receptacle #187 and are
.
Note: The numbers shown in parentheses are for air-feeding.
G5CA-1A-TP-E
Type
#187 terminals
(width: 4.75 mm)
(quick-connect terminals).
suitable for positive-lock mounting.
Use only Faston terminals with the specified numbers. Select leads
for connecting Faston receptacles with wire diameters that are
within the allowable range for the load current. Do not apply exces-
sive force to the terminals when mounting or dismounting the Fas-
ton receptacle.
Insert and remove terminals carefully one at a time. Do not insert
terminals on an angle, or insert/remove multiple terminals at the
same time.
The following positive-lock connectors made by AMP are recom-
mended. Contact the manufacturer directly for details on connec-
tors including availability.
Pitch:
2.54 mm × 4 min.
between terminals
Receptacle terminals
(see note)
AMP 170330-1
(170324-1)
AMP 170331-1
(170325-1)
AMP 170332-1
(170326-1)
(10.9)*
3.6
11
Pitch: 2.54 mm × 3 min. between terminals
0.3
16.1
25.1max.
(24.9)*
1
Positive housing
AMP 172074-1 (natural
color)
AMP 172074-4 (yellow)
AMP 172074-5 (green)
AMP 172074-6 (blue)
4.8
5
* Average value
1.35
1.3 dia.
3.2
0.3
6.35
4.9
13.3
10˚
22.1max.
14.25
(21.9)*
±1˚
17.78
0.5
0.5
Charged Terminals
The section marked with dotted circles (indicated by arrows) in the
following diagram includes the charged terminals of the relay. When
the relay is mounted on a PCB, make sure that there are no metal
patterns on the section of the PCB facing the portion of the relay
shaded in the following diagram.
.
Other Precautions
• The G5CA is a power relay designed for applications switching
• Use fully sealed models if the relays will require washing. Flux-pro-
power loads such as heaters in electric household appliances. Do
not use the G5CA to switch micro loads less than 100 mA, such as
in signal applications.
tection models may malfunction or the relay's performance may be
otherwise adversely affected if cleaning fluid enters the relay.
0.6
17.78
1.6
Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Charged
terminals
Two, 1 dia.
16.1
21.1
PCB Relay
5
1.8
Four, 1.2 dia.
elliptic holes
Terminal Arrangement/
Internal Connections
6.25
8
14.25
(No coil polarity)
6.5
(BOTTOM VIEW)
G5CA
(BOTTOM VIEW)
(TOP VIEW)
2
1
12.7
0.18
4
3
189

Related parts for G5CA-1A4 DC12